Determination of benzene in gasoline using direct injection-mass spectrometry

被引:6
作者
Perez Pavon, Jose Luis [1 ]
del Nogal Sanchez, Miguel [1 ]
Fernandez Laespada, M. Esther [1 ]
Garcia Pinto, Carmelo [1 ]
Moreno Cordero, Bernardo [1 ]
机构
[1] Univ Salamanca, Fac Ciencias Quim, Dept Quim Analit Nutr & Bromatol, E-37008 Salamanca, Spain
关键词
benzene; gasoline; direct injection; mass spectrometry;
D O I
10.1016/j.aca.2006.06.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-speed determination of benzene in gasoline samples using a non-separative method based on direct injection into the mass spectrometer is proposed. The results obtained are very similar to those provided with fast GC-MS. The calibration set was made up of gasoline samples in which the benzene was determined chromatographically and samples of gasoline subjected to a process of evaporation - until the complete disappearance of the original benzene - to which known concentrations of this compound had been added. A PLS1 multivariate calibration model was constructed. Cross-validation was used to select the optimum number of PLS components. The prediction capacity of the model was checked with an additional group of gasoline samples that had not been used either in the construction or in the validation of the model. With the direct injection method proposed here it was possible to analyse 24 samples over a period of 1 h. The direct injection method is rapid, simple and - in view of the results - highly suitable for the determination of benzene in gasoline samples. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:156 / 162
页数:7
相关论文
共 19 条
[1]  
*AG TECHN, 1999, ENH CHEMSTAT G1701CA
[2]  
*AM C GOV IND HYG, 1995, TLVS THRESH LIM VAL
[3]  
[Anonymous], 1982, IARC Monogr Eval Carcinog Risk Chem Hum, V29, P93
[4]  
*ASTM, 1997, D576995 ASTM
[5]  
*ASTM, 1997, D30696 ASTM
[6]   Factors affecting signal intensity in headspace mass spectrometry for the determination of hydrocarbon pollution in beach sands [J].
del Nogal Sánchez, M ;
Pavón, JLP ;
Laespada, MEF ;
Pinto, CG ;
Moreno Cordero, B .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (02) :372-380
[7]  
Frysinger GS, 1999, HRC-J HIGH RES CHROM, V22, P195
[8]   Headspace microdrop analysis - an alternative test method for gasoline diluent and benzene, toluene, ethylbenzene and xylenes in used engine oils [J].
Kokosa, JM ;
Przyjazny, A .
JOURNAL OF CHROMATOGRAPHY A, 2003, 983 (1-2) :205-214
[9]   Modified Jack-knife estimation of parameter uncertainty in bilinear modelling by partial least squares regression (PLSR) [J].
Martens, H ;
Martens, M .
FOOD QUALITY AND PREFERENCE, 2000, 11 (1-2) :5-16
[10]   Fast gas chromatography and its use in trace analysis [J].
Matisová, E ;
Dömötörová, M .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :199-221