Effect of the Harmonic Voltage Distortion on the Efficiency of a Compact Fluorescent Lamp

被引:1
作者
Rojas-Osorio, Esteban [1 ]
Saavedra-Montes, Andres Julian [1 ]
Ramos-Paja, Carlos Andres [1 ]
机构
[1] Univ Nacl Colombia, Medellin, Colombia
来源
REVISTA FACULTAD DE INGENIERIA, UNIVERSIDAD PEDAGOGICA Y TECNOLOGICA DE COLOMBIA | 2020年 / 29卷 / 54期
关键词
compact fluorescent lamp; efficiency reduction; electrical machine laboratory; harmonic source; voltage harmonic distortion; REDUCTIONS;
D O I
10.19053/01211129.v29.n54.2020.11604
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper evaluates the effect of the voltage harmonic distortion over the efficiency of a compact fluorescent lamp that is fed with a constant RMS voltage and constant frequency. Several works have been published about the assessment of compact fluorescent lamps, but the effect of the voltage distortion over the efficiency is still an open topic. This work focuses on designing an experiment to estimate the efficiency of a compact fluorescent lamp while changing the voltage harmonic distortion of the power supply. First, a mathematical model that represents a bus susceptible to harmonic distortion (high impedance) that feeds the compact fluorescent lamp is analyzed. Then the mathematical model is reproduced through a test bench in a laboratory of rotating electrical machines. The test bench produces a three-phase bus with constant voltage and frequency, and variable voltage harmonic distortion. The compact fluorescent lamp is subjected to varying harmonic voltage distortion while recording its electrical variables and the produced lumens to estimate its efficiency. That is a practical approach to calculate the lamp efficiency while several works limit their scope measuring only the efficiency of the input converter. The experimental results show that a variation of the voltage harmonic distortion of 8 % on a compact fluorescent lamp reduces its efficiency. Those results put into evidence the importance of regulating harmonic distortion limits to reduce or prevent the increment of power losses caused by harmonic components.
引用
收藏
页数:16
相关论文
共 7 条
[1]  
Bollen M, 2014, INT C HARMON QUAL PO, P904, DOI 10.1109/ICHQP.2014.6842870
[2]  
George Victor., 2011, Utility Exhibition on Power and Energy Systems: Issues Prospects for Asia (ICUE), 2011 International Conference and, P1
[3]  
IEEEStd115, 2010, IEEE Standard 1459, V115, P1, DOI [DOI 10.1109/IEEESTD.2010.5439063, 10.1109/IEEESTD.2010.5464495, 10.1109/IEEESTD.2010.5399061, DOI 10.1109/IEEESTD.2010.5557731]
[4]   Policies to promote energy efficiency and air emissions reductions in China's electric power generation sector during the 11th and 12th five-year plan periods: Achievements, remaining challenges, and opportunities [J].
Li, Mingquan ;
Patino-Echeverri, Dalia ;
Zhang, Junfeng .
ENERGY POLICY, 2019, 125 :429-444
[5]   Indices for comparative assessment of the harmonic effect of different home appliances [J].
Nassif, Alexandre B. ;
Yong, Jing ;
Xu, Wilsun ;
Chung, C. Y. .
INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2013, 23 (05) :638-654
[6]   Loss minimization techniques for optimal operation and planning of distribution systems: A review of different methodologies [J].
Sambaiah, Kola Sampangi ;
Jayabarathi, Thangavelu .
INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2020, 30 (02)
[7]   Reductions in electricity losses in the distribution power system in case of the mass use of compact fluorescent lamps [J].
Trifunovic, J. ;
Mikulovic, J. ;
Djurisic, Z. ;
Kostic, M. .
ELECTRIC POWER SYSTEMS RESEARCH, 2011, 81 (02) :465-477