DIRECTT reconstructions compared to filtered back projections

被引:1
|
作者
Lange, Axel [1 ]
Kupsch, Andreas [2 ]
Hentschel, Manfred P. [3 ,4 ]
Mueller, Bernd R. [5 ,6 ]
机构
[1] BAM, Zerstorungs Freien Prufung Wesentl Einrichtung &, Brooklyn, NY USA
[2] BAM ZfP Tatig, Munich, Germany
[3] BAM Bereich Zerstorungsfreie Prufung, Munich, Germany
[4] Tech Univ Berlin, Berlin, Germany
[5] Europaischen Labs Synchrotronstrahlung, Berlin, Germany
[6] BAM Bereich ZfP Engagiert, Berlin, Germany
关键词
COMPUTED-TOMOGRAPHY; DATA SETS; ALGORITHM;
D O I
10.3139/120.110610
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Based on measurements and on model calculations tomographic reconstructions by DIRECTT (direct iterative reconstruction of computed tomography trajectories) are evaluated in comparison to filtered back projection. This is established by modified circular Modulation Transfer Functions (MTF) and by integral parameters in Radon and real space. The reconstructions of the experimental data refer to measurements of simple shapes under well defined physical conditions such as monochromatic radiation, suppression of refractive edge artifacts and radiometric intensity measurement. The quality of DIRECTT reconstructions does not primarily depend on the type of filters applied nor their abandonment, which differs essentially from the performance of the filtered back projection.
引用
收藏
页码:709 / 715
页数:7
相关论文
共 50 条
  • [31] Improved Accuracy of Pulmonary Embolism Computer-Aided Detection Using Iterative Reconstruction Compared With Filtered Back Projection
    Lahiji, Kian
    Kligerman, Seth
    Jeudy, Jean
    White, Charles
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (04) : 763 - 771
  • [32] Saturation rates of filtered back projection approximations
    Matthias Beckmann
    Armin Iske
    Calcolo, 2020, 57
  • [33] Acceleration method of the filtered back projection algorithm
    Qiao, Zhi-Wei
    Han, Yan
    Wei, Xue-Ye
    Xi Tong Gong Cheng Yu Dian Zi Ji Shu/Systems Engineering and Electronics, 2010, 32 (02): : 401 - 404
  • [34] Angular assessement of the Mojette filtered back projection
    Subirats, P
    Servières, M
    Normand, N
    Guédon, J
    MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 : 1951 - 1960
  • [35] Saturation rates of filtered back projection approximations
    Beckmann, Matthias
    Iske, Armin
    CALCOLO, 2020, 57 (01)
  • [36] Deep Filtered Back Projection for CT Reconstruction
    Tan, Xi
    Liu, Xuan
    Xiang, Kai
    Wang, Jing
    Tan, Shan
    IEEE ACCESS, 2024, 12 : 20962 - 20972
  • [37] 4 materials scene reconstructions from line Mojette projections
    Liu, Chuanlin
    Yadav, Amit
    Khan, Asif
    Zhang, Yi
    Bao, Yu
    Xue, Mei
    8TH INTERNATIONAL CONFERENCE ON ADVANCES IN COMPUTING & COMMUNICATIONS (ICACC-2018), 2018, 143 : 203 - 210
  • [38] Recent climate observations compared to projections
    Rahmstorf, Stefan
    Cazenave, Anny
    Church, John A.
    Hansen, James E.
    Keeling, Ralph F.
    Parker, David E.
    Somerville, Richard C. J.
    SCIENCE, 2007, 316 (5825) : 709 - 709
  • [39] Two-dimensional noise reconstruction in proton computed tomography using distance-driven filtered back-projection of simulated projections
    Raedler, Martin
    Landry, Guillaume
    Rit, Simon
    Schulte, Reinhard W.
    Parodi, Katia
    Dedes, George
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (21):
  • [40] ADAPTIVE FILTERED-BACK-PROJECTION FOR COMPUTED TOMOGRAPHY
    Shtok, Joseph
    Elad, Michael
    Zibulevsky, Michael
    2008 IEEE 25TH CONVENTION OF ELECTRICAL AND ELECTRONICS ENGINEERS IN ISRAEL, VOLS 1 AND 2, 2008, : 518 - 522