Wireless Brain-Computer Interface for Wheelchair Control by Using Fast Machine Learning and Real-Time Hyper-Dimensional Classification

被引:0
作者
Annese, Valerio F. [1 ]
Mezzina, Giovanni [2 ]
De Venuto, Daniela [2 ]
机构
[1] Univ Glasgow, Sch Engn, Glasgow G12 8TA, Lanark, Scotland
[2] Politecn Bari, Dept Elect & Informat Engn, Via Orabona 4, I-70125 Bari, Italy
来源
CURRENT TRENDS IN WEB ENGINEERING, ICWE 2017 | 2018年 / 10544卷
关键词
BCI; Machine learning; Classification; EEG; ERP P300; SYSTEM; BCI;
D O I
10.1007/978-3-319-74433-9_5
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a noninvasive brain-controlled P300-based wheelchair driven by EEG signals to be used by tetraplegic and paralytic users. The P300 - an Evoked Related Potential (ERP) - is induced for purpose by visual stimuli. The developed Brain-Computer Interface is made up by: (i) acquisition unit; (ii) processing unit and (iii) navigation unit. The acquisition unit is a wireless 32-channel EEG headset collecting data from 6 electrodes (parietal-cortex area). The processing unit is a dedicated mu PC performing stimuli delivery, data gathering, Machine Learning (ML), real-time hyper-dimensional classification leading to the user intention interpretation. The ML stage is based on a custom algorithm (t-RIDE) which trains the following classification stage on the user-tuned P300 reference features. The real-time classification performs a functional approach for time-domain features extraction, which reduce the amount of data to be analyzed. The Raspberry-based navigation unit actuates the received commands and support the wheelchair motion using peripheral sensors (USB camera for video processing, ultrasound sensors). Differently from related works, the proposed protocol for stimulation is aware of the environment. The experimental results, based on a dataset of 5 subjects, demonstrate that: (i) the implemented ML algorithm allows a complete P300 spatio-temporal characterization in 1.95 s using only 22 target brain visual stimuli (88 s/direction); (ii) the complete classification chain (from features extraction to validation) takes in the worst case only 19.65 ms +/- 10.1, allowing real-time control; (iii) the classification accuracy of the implemented BCI is 80.5 +/- 4.1% on single-trial.
引用
收藏
页码:61 / 74
页数:14
相关论文
共 35 条
[1]  
Annese VF, 2016, IEEE INT SYMP CIRC S, P1370, DOI 10.1109/ISCAS.2016.7527504
[2]  
Annese VF, 2016, DES AUT TEST EUROPE, P714
[3]  
Annese VF, 2015, IEEE INT SYMP SIGNAL, P553, DOI 10.1109/ISSPIT.2015.7394398
[4]  
Annese V. F., 2015, 2015 IEEE Biomedical Circuits and Systems Conference (BioCAS), P1, DOI 10.1109/BioCAS.2015.7348366
[5]  
Annese VF, 2015, 2015 6TH IEEE INTERNATIONAL WORKSHOP ON ADVANCES IN SENSORS AND INTERFACES (IWASI), P116, DOI 10.1109/IWASI.2015.7184953
[6]  
Annese VF, 2014, IEEE I C ELECT CIRC, P598, DOI 10.1109/ICECS.2014.7050056
[7]  
Annese V. F., 2014, P INT C SENS TECHN, P130
[8]  
Annese V. F., 2017, P 2017 12 IEEE INT C
[9]  
Annese VF, 2015, 2015 IEEE 15TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (IEEE EEEIC 2015), P605, DOI 10.1109/EEEIC.2015.7165232
[10]  
[Anonymous], 2015, INT C DESIGN TECHNOL