Analysing drying unit performance in a continuous pharmaceutical manufacturing line by means of mass - Energy balances

被引:17
作者
Mortier, Severine Therese F. C. [1 ,2 ]
Gernaey, Krist V. [3 ]
De Beer, Thomas [2 ]
Nopens, Ingmar [1 ]
机构
[1] Univ Ghent, Dept Math Modelling Stat & Bioinformat, B-9000 Ghent, Belgium
[2] Univ Ghent, Dept Pharmaceut Anal, B-9000 Ghent, Belgium
[3] Tech Univ Denmark, Dept Chem & Biochem Engn, DK-2800 Lyngby, Denmark
关键词
In-line univariate measurements; Mass balance; Energy balance; Process monitoring; Pharmaceutical engineering; Drying process; NEAR-INFRARED SPECTROSCOPY; CONTINUOUS GRANULATION; GRANULES; MOISTURE; SYSTEMS; PROPAGATION; UNCERTAINTY; HYPERCUBE; INDUSTRY; TRENDS;
D O I
10.1016/j.ejpb.2013.12.014
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The current trend in the pharmaceutical industry to move from batch-wise to continuous production processes strengthens the need for monitoring and controlling the process in-line. The ConsiGma(Tm) continuous tableting line collects data of the different subunits in real-time, but these are not really used. In this paper the data of the six-segmented fluidized bed dryer in the line are used for the development and evaluation of a mass and energy balance. The objectives are multiple: (1) prediction of the,moisture content of the granules leaving the dryer solely based on the currently logged data and (2) prediction of the gas outlet temperature to check the mass balances. Once a validated system is established the gas temperature in different horizontal sections of the drying unit can be predicted. Calculations are also used to identify errors in the system and to propose alternative sensor locations. A calibration is performed in order to predict the evaporation rate. The balances were able to predict both the moisture content of the granules at the end of the drying process and the gas outlet temperature quite accurately. Combining the gathered information with the height of the bed in the fluidized bed can be used to predict the gas temperature in different horizontal sections of the dryer. An extra sensor measuring the gas temperature and the humidity at the wet transfer line would increase the accuracy of the calculations. An extra gas velocity sensor at the outlet would be useful to incorporate an extra supervision of the calculations. (C) 2013 Elsevier BAT. All rights reserved.
引用
收藏
页码:532 / 543
页数:12
相关论文
共 24 条
  • [1] ERROR PROPAGATION BY MONTE-CARLO METHOD IN GEOCHEMICAL CALCULATIONS
    ANDERSON, GM
    [J]. GEOCHIMICA ET COSMOCHIMICA ACTA, 1976, 40 (12) : 1533 - 1538
  • [2] BUCK AL, 1981, J APPL METEOROL, V20, P1527, DOI 10.1175/1520-0450(1981)020<1527:NEFCVP>2.0.CO
  • [3] 2
  • [4] In-line monitoring of granule moisture in fluidized-bed dryers using microwave resonance technology
    Buschmueller, Caroline
    Wiedey, Wolfgang
    Doescher, Claas
    Dressler, Jochen
    Breitkreutz, Joerg
    [J]. EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2008, 69 (01) : 380 - 387
  • [5] Active pharmaceutical ingredient (API) production involving continuous processes - A process systems engineering (PSE)-assisted design framework
    Cervera-Padrell, Albert E.
    Skovby, Tommy
    Kiil, Soren
    Gani, Rafiqul
    Gernaey, Krist V.
    [J]. EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2012, 82 (02) : 437 - 456
  • [6] Inline Real-Time Near-Infrared Granule Moisture Measurements of a Continuous Granulation-Drying-Milling Process
    Chablani, Lipika
    Taylor, Michael K.
    Mehrotra, Amit
    Rameas, Patrick
    Stagner, William C.
    [J]. AAPS PHARMSCITECH, 2011, 12 (04): : 1050 - 1055
  • [7] Fontani M., 2011, Information Forensics and Security (WIFS), 2011 IEEE International Workshop on Information Forensics and Security, P1, DOI DOI 10.1109/WIFS.2011.6123156
  • [8] Process control and end-point determination of a fluid bed granulation by application of near infra-red spectroscopy
    Frake, P
    Greenhalgh, D
    Grierson, SM
    Hempenstall, JM
    Rudd, DR
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1997, 151 (01) : 75 - 80
  • [9] Latin hypercube sampling and the propagation of uncertainty in analyses of complex systems
    Helton, JC
    Davis, FJ
    [J]. RELIABILITY ENGINEERING & SYSTEM SAFETY, 2003, 81 (01) : 23 - 69
  • [10] Evaluation of measurement uncertainty in analytical assays by means of Monte-Carlo simulation
    Herrador, MA
    González, AG
    [J]. TALANTA, 2004, 64 (02) : 415 - 422