Raman Analysis Reveals Biochemical Differences in Plasma of Crohn's Disease Patients

被引:16
作者
Morasso, Carlo [1 ]
Truffi, Marta [1 ]
Vanna, Renzo [1 ]
Albasini, Sara [1 ]
Mazzucchelli, Serena [2 ]
Colombo, Francesco [3 ]
Sorrentino, Luca [1 ]
Sampietro, Gianluca [3 ]
Ardizzone, Sandro [3 ]
Corsi, Fabio [1 ,2 ]
机构
[1] Ist Clin Sci Maugeri IRCCS, Pavia, Italy
[2] Univ Milan, Dept Biomed & Clin Sci Luigi Sacco, Milan, Italy
[3] ASST Fatebenefratelli Sacco Osped Luigi Sacco, Polo Univ, Milan, Italy
关键词
Raman spectroscopy; Crohn's disease; blood plasma; biomarker; INFLAMMATORY-BOWEL-DISEASE; FECAL CALPROTECTIN; OXIDATIVE STRESS; VITAMIN-A; DIAGNOSTIC PRECISION; ULCERATIVE-COLITIS; SPECTROSCOPY; IDENTIFICATION; ANTIBODIES; MARKERS;
D O I
10.1093/ecco-jcc/jjaa080
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Backgrounds and Aims: There is no accurate and reliable circulating biomarker to diagnose Crohn's disease [CD]. Raman spectroscopy is a relatively new approach that provides information on the biochemical composition of samples in minutes and virtually without any sample preparation. We aimed to test the use of Raman spectroscopy analysis of plasma samples as a potential diagnostic tool for CD. Methods: We analysed by Raman spectroscopy dry plasma samples obtained from 77 CD patients [CD] and 45 healthy controls [HC]. In the dataset obtained, we analysed spectra differences between CD and HC, as well as among CD patients with different disease behaviours. We also developed a method, based on principal component analysis followed by a linear discrimination analysis [PCA-LDA], for the automatic classification of individuals based on plasma spectra analysis. Results: Compared with HC, the CD spectra were characterised by less intense peaks corresponding to carotenoids [p <10(-4)] and by more intense peaks corresponding to proteins with beta-sheet secondary structure [p<10(-4)]. Differences were also found on Raman peaks relative to lipids [p= 0.00071 and aromatic amino acids [p <10(-4)]. The predictive model we developed was able to classify CD and HC subjects with 83.6% accuracy [sensitivity 80.0% and specificity 85.7%] and F1-score of 86.8%. Conclusions: Our results indicate that Raman spectroscopy of blood plasma can identify metabolic variations associated with CD and it could be a rapid pre-screening tool to use before further specific evaluation.
引用
收藏
页码:1572 / 1580
页数:9
相关论文
共 42 条
  • [21] Mahadevan-Jansen A, 1996, J Biomed Opt, V1, P31, DOI 10.1117/12.227815
  • [22] From bench to bedside: fecal calprotectin in inflammatory bowel diseases clinical setting
    Mumolo, Maria Gloria
    Bertani, Lorenzo
    Ceccarelli, Linda
    Laino, Gabriella
    Di Fluri, Giorgia
    Albano, Eleonora
    Tapete, Gherardo
    Costa, Francesco
    [J]. WORLD JOURNAL OF GASTROENTEROLOGY, 2018, 24 (33) : 3681 - 3694
  • [23] Vibrational biospectroscopy coupled with multivariate analysis extracts potentially diagnostic features in blood plasma/serum of ovarian cancer patients
    Owens, Gemma L.
    Gajjar, Ketan
    Trevisan, Julio
    Fogarty, Simon W.
    Taylor, Sian E.
    Da Gama-Rose, Bianca
    Martin-Hirsch, Pierre L.
    Martin, Francis L.
    [J]. JOURNAL OF BIOPHOTONICS, 2014, 7 (3-4) : 200 - 209
  • [24] Intensity of Proliferative Processes and Degree of Oxidative Stress in the Mucosa of the Ileum in Crohn's Disease
    Ozhegov, E. V.
    Zhivotova, E. Yu
    Lebedko, O. A.
    Fleishman, M. Yu
    Alexeenko, S. A.
    Timoshin, S. S.
    [J]. BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2012, 152 (04) : 420 - 423
  • [25] Raman spectroscopic screening of high and low molecular weight fractions of human serum
    Parachalil, Drishya Rajan
    Bruno, Clement
    Bonnier, Franck
    Blasco, Helene
    Chourpa, Igor
    McIntyre, Jennifer
    Byrne, Hugh J.
    [J]. ANALYST, 2019, 144 (14) : 4295 - 4311
  • [26] Raman Spectroscopy to Diagnose Alzheimer's Disease and Dementia with Lewy Bodies in Blood
    Paraskevaidi, Maria
    Morais, Camilo L. M.
    Halliwell, Diane E.
    Mann, David M. A.
    Allsop, David
    Martin-Hirsch, Pierre L.
    Martin, Francis L.
    [J]. ACS CHEMICAL NEUROSCIENCE, 2018, 9 (11): : 2786 - 2794
  • [27] Diagnostic accuracy and clinical application of faecal calprotectin in adult patients presenting with gastrointestinal symptoms in primary care
    Pavlidis, Polychronis
    Chedgy, Fergus J. Q.
    Tibble, Jeremy A.
    [J]. SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2013, 48 (09) : 1048 - 1054
  • [28] Clinical characterization of in vivo inflammatory bowel disease with Raman spectroscopy
    Pence, Isaac J.
    Beaulieu, Dawn B.
    Horst, Sara N.
    Bi, Xiaohong
    Herline, Alan J.
    Schwartz, David A.
    Mahadevan-Jansen, Anita
    [J]. BIOMEDICAL OPTICS EXPRESS, 2017, 8 (02): : 524 - 535
  • [29] C-reactive protein: a critical update
    Pepys, MB
    Hirschfield, GM
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 2003, 111 (12) : 1805 - 1812
  • [30] Diagnostic precision of anti-Saccharomyces cerevisiae antibodies and perinuclear antineutrophil cytoplasmic antibodies in inflammatory bowel disease
    Reese, George E.
    Constantinides, Vasilis A.
    Simillis, Constantinos
    Darzi, Ara W.
    Orchard, Timothy R.
    Fazio, Victor W.
    Tekkis, Paris P.
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2006, 101 (10) : 2410 - 2422