A stable approach for coupling multidimensional cardiovascular and pulmonary networks based on a novel pressure-flow rate or pressure-only Neumann boundary condition formulation

被引:19
作者
Ismail, M. [1 ]
Gravemeier, V. [1 ]
Comerford, A. [1 ]
Wall, W. A. [1 ]
机构
[1] Tech Univ Munich, Inst Computat Mech, D-85747 Garching, Germany
关键词
Neumann boundary conditions; coupled multidimensional models; cardiovascular; respiratory; biofluid networks; COMPUTATIONAL FLUID-DYNAMICS; BLOOD-FLOW; NUMERICAL-SIMULATION; HUMAN LUNG; AIR-FLOW; MODEL; GALERKIN; VALIDATION; TRANSPORT; ARTERIES;
D O I
10.1002/cnm.2611
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In many biomedical flow problems, reversed flows along with standard treatment of Neumann boundary conditions can cause instabilities. We have developed a method that resolves these instabilities in a consistent way while maintaining correct pressure and flow rate values. We also are able to remove the necessary prescription of both pressure and velocities/flow rates to problems where only pressure is known. In addition, the method is extended to coupled 3D/reduced-D fluid and fluid-structure interaction models. Numerical examples mainly focus on using Neumann boundary condition in cardiovascular and pulmonary systems, particularly, coupled with 3D-1D and 3D-0D models. Inflow pressure, traction, and impedance boundary conditions are first tested on idealized tubes for various Womersley numbers. Both pressure and flow rate are shown to match the analytical solutions for these examples. Our method is then tested on a coupled 1D-3D-1D artery example, demonstrating the power and simplicity of extending this method toward fluid-structure interaction. Finally, the proposed method is investigated for a coupled 3D-0D patient-specific full lung model during spontaneous breathing. All coupled 3D/reduced-D results show a perfect matching of pressure and flow rate between 3D and corresponding reduced-D boundaries. The methods are straight-forward to implement in contrast to using Lagrange multipliers as previously proposed in other studies. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:447 / 469
页数:23
相关论文
共 41 条
[1]  
Alastruey J, 2008, COMMUN COMPUT PHYS, V4, P317
[2]  
Barkow U, 2007, CT IMAGES PROVIDED M
[3]   Patient-specific isogeometric fluid-structure interaction analysis of thoracic aortic blood flow due to implantation of the Jarvik 2000 left ventricular assist device [J].
Bazilevs, Y. ;
Gohean, J. R. ;
Hughes, T. J. R. ;
Moser, R. D. ;
Zhang, Y. .
COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2009, 198 (45-46) :3534-3550
[4]   A unified variational approach for coupling 3D-1D models and its blood flow applications [J].
Blanco, P. J. ;
Feijoo, R. A. ;
Urquiza, S. A. .
COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2007, 196 (41-44) :4391-4410
[5]   Numerical simulation of respiratory flow patterns within human lung [J].
Calay, RK ;
Kurujareon, J ;
Holdo, AE .
RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2002, 130 (02) :201-221
[6]   Nanoparticle transport in a realistic model of the tracheobronchial region [J].
Comerford, A. ;
Bauer, G. ;
Wall, W. A. .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2010, 26 (07) :904-914
[7]   Structured Tree Impedance Outflow Boundary Conditions for 3D Lung Simulations [J].
Comerford, Andrew ;
Foerster, Christiane ;
Wall, Wolfgang A. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2010, 132 (08)
[8]   Analysis of a geometrical multiscale blood flow model based on the coupling of ODEs and hyperbolic PDEs [J].
Fernández, MA ;
Milisic, V ;
Quarteroni, A .
MULTISCALE MODELING & SIMULATION, 2005, 4 (01) :215-236
[9]   Effect of Curvature on Displacement Forces Acting on Aortic Endografts: A 3-Dimensional Computational Analysis [J].
Figueroa, C. Alberto ;
Taylor, Charles A. ;
Yeh, Victoria ;
Chiou, Allen J. ;
Zarins, Christopher K. .
JOURNAL OF ENDOVASCULAR THERAPY, 2009, 16 (03) :284-294
[10]  
Formaggia L., 1999, Computing and Visualization in Science, V2, P75, DOI 10.1007/s007910050030