Quantitative Assessment of Amide Proton Transfer (APT) and Nuclear Overhauser Enhancement (NOE) Imaging with Extrapolated Semi-Solid Magnetization Transfer Reference (EMR) Signals: Application to a Rat Glioma Model at 4.7 Tesla

被引:133
作者
Heo, Hye-Young [1 ]
Zhang, Yi [1 ]
Lee, Dong-Hoon [1 ]
Hong, Xiaohua [1 ]
Zhou, Jinyuan [1 ,2 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Radiol, Div MR Res, Baltimore, MD 21287 USA
[2] Kennedy Krieger Inst, FM Kirby Res Ctr Funct Brain Imaging, Baltimore, MD USA
基金
美国国家卫生研究院;
关键词
MT; CEST; APT; NOE; brain tumor; EXCHANGE SATURATION-TRANSFER; MRI CONTRAST AGENT; CHEMICAL-EXCHANGE; IN-VIVO; TRANSFER CEST; HUMAN BRAIN; PARACEST AGENTS; 7; T; ISCHEMIC PENUMBRA; WATER SATURATION;
D O I
10.1002/mrm.25581
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To quantify amide proton transfer (APT) and nuclear Overhauser enhancement (NOE) contributions to in vivo chemical exchange saturation transfer MRI signals in tumors. Theory and Methods: Two-pool (free water and semi-solid protons) and four-pool (free water, semi-solid, amide, and upfield NOE-related protons) tissue models combined with the super-Lorentzian lineshape for semi-solid protons were used to fit wide and narrow frequency-offset magnetization-transfer (MT) data, respectively. Extrapolated semi-solid MT signals at 3.5 and 3.5 ppm from water were used as reference signals to quantify APT and NOE, respectively. Six glioma-bearing rats were scanned at 4.7 Tesla. Quantitative APT and NOE signals were compared at three saturation power levels. Results: The observed APT signals were significantly higher in the tumor (center and rim) than in the contralateral normal brain tissue at all saturation powers, and were the major contributor to the APT-weighted image contrast (based on MT asymmetry analysis) between the tumor and the normal brain tissue. The NOE (a positive confounding factor) enhanced this APT-weighted image contrast. The fitted amide pool sizes were significantly larger, while the NOE-related pool sizes were significantly smaller in the tumor than in the normal brain tissue. Conclusion: The extrapolated semi-solid magnetization transfer reference provides a relatively accurate approach for quantitatively measuring pure APT and NOE signals. (C) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:137 / 149
页数:13
相关论文
共 3 条
  • [1] Quantitative Assessment of Amide Proton Transfer (APT) and Nuclear Overhauser Enhancement (NOE) Imaging with Extrapolated Semisolid Magnetization Transfer Reference (EMR) Signals: II. Comparison of Three EMR Models and Application to Human Brain Glioma at 3 Tesla
    Heo, Hye-Young
    Zhang, Yi
    Jiang, Shanshan
    Lee, Dong-Hoon
    Zhou, Jinyuan
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (04) : 1630 - 1639
  • [2] Quantitative assessment of the effects of water proton concentration and water T1 changes on amide proton transfer (APT) and nuclear overhauser enhancement (NOE) MRI: The origin of the APT imaging signal in brain tumor
    Lee, Dong-Hoon
    Heo, Hye-Young
    Zhang, Kai
    Zhang, Yi
    Jiang, Shanshan
    Zhao, Xuna
    Zhou, Jinyuan
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (02) : 855 - 863
  • [3] Whole-Brain Amide Proton Transfer (APT) and Nuclear Overhauser Enhancement (NOE) Imaging in Glioma Patients Using Low-Power Steady-State Pulsed Chemical Exchange Saturation Transfer (CEST) Imaging at 7T
    Heo, Hye-Young
    Jones, Craig K.
    Hua, Jun
    Yadav, Nirbhay
    Agarwal, Shruti
    Zhou, Jinyuan
    van Zijl, Peter C. M.
    Pillai, Jay J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (01) : 41 - 50