Experimental study on biological damage in bone in vibrational drilling

被引:4
作者
Alam, Khurshid [1 ]
Iqbal, Muhammad [2 ]
Umer, Jamal [3 ]
Amjad, Muhammad [4 ]
Al-Ghaithi, Ahmed [5 ]
机构
[1] Sultan Qaboos Univ, Mech & Ind Engn Dept, Al Khoud, Oman
[2] Deans Ctr, Creat Engn & Management Serv, Peshawar, Pakistan
[3] Univ Engn & Technol, Dept Mech Engn, Lahore, Pakistan
[4] Int Islamic Univ, Dept Mech Engn, Sect H-11, Islamabad, Pakistan
[5] Sohar Hosp, Dept Surg, Sohar, Oman
关键词
Bone; bone drilling; vibrational drilling; bone temperature; cell damage; bone histology; CORTICAL BONE; IN-VITRO; TEMPERATURE; PARAMETERS; FORCE;
D O I
10.3233/BME-201122
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
BACKGROUND: Drilling is a well-known mechanical operation performed for fixing fracture at required locations in bone. The process may produce mechanical and thermal alterations in the structure of the bone and surrounding tissues leading to irreversible damage known as osteonecrosis. OBJECTIVE: The main purpose of this study was to measure the level of biological damage in bone when a drill assisted by low and high levels of vibrations is penetrated into bone tissue. METHODS: Histopathology examination of sections of bones has been performed after drilling the bone using a range of vibrational frequency and rotational speed imposed on the drill with and without supply of saline for cooling. RESULTS: Cell damage in bone was caused by the combined effect of drill speed and frequency of vibrations. Histopathology examination revealed more damage to bone cells when a frequency higher than 20 kHz was used in the absence of cooling. Cooling the drilling region helped minimize cell damage more at a shallow depth of drilling compared to deep drilling in the cortex of cortical bone. The contribution of cooling in minimizing cell damage was higher with a lower drill speed and frequency compared to a higher drill speed and frequency. CONCLUSION: Vibrational drilling using a lower drill speed and frequency below 25 kHz in the presence of cooling was found to be favorable for safe and efficient drilling in bone.
引用
收藏
页码:269 / 277
页数:9
相关论文
共 50 条
  • [41] Ultrasonic longitudinal torsion-assisted biotic bone drilling: An experimental study
    Li, Zhenhao
    Yang, Zhibo
    Wang, Wei
    Guo, Qiang
    Sun, Wang
    Han, Daocheng
    Liu, Xiaoning
    Zhang, Yanru
    REVIEWS ON ADVANCED MATERIALS SCIENCE, 2023, 62 (01)
  • [42] Effects of various drilling parameters on bone during implantology: An in vitro experimental study
    Karaca, Faruk
    Aksakal, Bunyamin
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2013, 15 (04) : 25 - 32
  • [43] Dimpled drill-bit to minimize thrust-force in bone drilling with in-vitro experimental validation
    Ul Meiraj, Syed Naveed
    Pandithevan, Ponnusamy
    Prasannavenkadesan, Varatharajan
    Narayan, Roger J.
    MACHINING SCIENCE AND TECHNOLOGY, 2025, 29 (02) : 159 - 186
  • [44] Appraising efficiency of OpSite as coolant in drilling of bone
    Effatparvar, Mohammad Reza
    Jamshidi, Nima
    Mosavar, Alireza
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [45] Modelling and experimental validation for thrust force and heat generation during bone drilling
    Singh, Gurmeet
    Jindal, Rohit
    Jain, Vivek
    Gupta, Dheeraj
    Babbar, Atul
    Gupta, Pawan Kumar
    INTERNATIONAL JOURNAL OF INTERACTIVE DESIGN AND MANUFACTURING - IJIDEM, 2023,
  • [46] On the importance of precision in cortical bone drilling: Integrating experimental validation and computational modeling
    Einafshar, Mohammadjavad
    Rajaeirad, Mohadese
    Ghazijahani, Ahmad Babazadeh
    Andersen, Michael Skipper
    JOURNAL OF ORTHOPAEDICS, 2024, 56 : 70 - 76
  • [47] Comparison of Cortical Bone Drilling Induced Heat Production Among Common Drilling Tools
    Palmisano, Andrew C.
    Tai, Bruce L.
    Belmont, Barry
    Irwin, Todd A.
    Shih, Albert
    Holmes, James R.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (05) : E188 - E193
  • [48] Experimental Study of Thrust Force and Torque for Drilling Cortical Bone
    Sui, Jianbo
    Sugita, Naohiko
    ANNALS OF BIOMEDICAL ENGINEERING, 2019, 47 (03) : 802 - 812
  • [49] EXPERIMENTAL STUDY ON THE EFFECT OF DRILL QUALITY ON BONE TEMPERATURE IN DRILLING
    Alam, Khurshid
    Imran, Syed Husain
    Al-Shabibi, Abdullah
    Ghodsi, Mojtaba
    Silberschmidth, Vadim
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2018, 30 (02):
  • [50] Experimental Study on the Effect of Point Angle on Force and Temperature in Ultrasonically Assisted Bone Drilling
    Khurshid Alam
    Mojtaba Ghodsi
    Abdullah Al-Shabibi
    Vadim Silberschmidt
    Journal of Medical and Biological Engineering, 2018, 38 : 236 - 243