CCM and DCM Analysis of Quasi-Z-Source Derived Push-Pull DC/DC Converter

被引:0
作者
Chub, Andrii [1 ]
Husev, Oleksandr [1 ,3 ]
Blinov, Andrei [1 ,2 ]
Vinnikov, Dmitri [1 ]
机构
[1] Tallinn Univ Technol, EE-19086 Tallinn, Estonia
[2] Royal Inst Technol, Stockholm, Sweden
[3] Chernihiv Natl Univ Technol, Chernihiv, Ukraine
来源
INFORMACIJE MIDEM-JOURNAL OF MICROELECTRONICS ELECTRONIC COMPONENTS AND MATERIALS | 2014年 / 44卷 / 03期
关键词
DC/DC converter; quasi-Z-source converter; galvanic isolation; renewable energy; steady state analysis; Z-SOURCE INVERTER;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a steady state analysis of the operation modes of the quasi-Z-source (qZS) derived push-pull DC/DC converter topology. It was derived by the combination of the qZS network and coupled inductors. The output stage of the converter consists of a diode bridge rectifier and an LC-filter. This topology provides a wide regulation range of the input voltage and galvanic isolation. These features fit the requirements for the integration systems of renewable energy sources, such as PV panels, variable speed wind turbines, and fuel cells. A converter can operate in continuous (CCM) and discontinuous conduction mode (DCM). Switching period is divided into four and six intervals for CCM and DCM, respectively. Equivalent circuits and analytical expressions for each interval are presented. The DC gain factor for each mode is derived. To simplify our analysis, coupled inductors were substituted with a model that consists of an ideal transformer and magnetizing inductance. Leakage inductances are neglected because the coupling coefficient in this topology should be close to unity. In DCM the converter operation depends on the active duty cycle and the duty cycle of the zero current condition. Two solutions are possible for the DC gain factor in DCM. It is theoretically impossible to achieve the unity DC gain factor in DCM if the turns ratio of coupled inductors is equal to or more than one. The proposed topology was simulated with PSIM software in two operating points. Experimental verification proves our theoretical and simulation results.
引用
收藏
页码:224 / 234
页数:11
相关论文
共 14 条
[1]   Four Quasi-Z-Source Inverters [J].
Anderson, Joel ;
Peng, F. Z. .
2008 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-10, 2008, :2743-2749
[2]  
[Anonymous], 2004, Fuel Cell Handbook, V7
[3]  
Blinov Andrei, 2013, International Conference and Exhibition for Power Electronics, Intelligent Motion, Renewable Energy and Energy Management. Proceedings, P1435
[4]   Development of an 85-kW Bidirectional Quasi-Z-Source Inverter With DC-Link Feed-Forward Compensation for Electric Vehicle Applications [J].
Guo, Feng ;
Fu, Lixing ;
Lin, Chien-Hui ;
Li, Cong ;
Choi, Woongchul ;
Wang, Jin .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (12) :5477-5488
[5]   Steady-State Analysis of qZS-Derived Push-Pull DC/DC Converter with Wide Input Voltage Regulation Range [J].
Husev, Oleksandr ;
Blinov, Andrei ;
Vinnikov, Dmitri ;
Chub, Andrii .
2013 8TH INTERNATIONAL CONFERENCE ON COMPATIBILITY AND POWER ELECTRONICS (CPE), 2013, :320-325
[6]  
Li Y, 2009, APPL POWER ELECT CO, P918, DOI 10.1109/APEC.2009.4802772
[7]  
Liu YS, 2011, IEEE ENER CONV, P291, DOI 10.1109/ECCE.2011.6063782
[8]  
Roncero-Clemente C., 2013, SCI J RIGA TU ELECT, V2, P14
[9]  
Roncero-Clemente C, 2013, IFIP ADV INF COMM TE, V394, P334
[10]   Optimum control strategies in energy conversion of PMSG wind turbine system without mechanical sensors [J].
Tan, K ;
Islam, S .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2004, 19 (02) :392-399