Repeatability of Chemical-Shift-Encoded Water-Fat MRI and Diffusion-Tensor Imaging in Lower Extremity Muscles in Children

被引:15
作者
Ponrartana, Skorn [1 ]
Andrade, Kristine E. [1 ]
Wren, Tishya A. L. [1 ,2 ]
Ramos-Platt, Leigh [3 ]
Hu, Houchun H. [1 ,4 ]
Bluml, Stefan [1 ]
Gilsanz, Vicente [1 ,2 ]
机构
[1] Childrens Hosp Los Angeles, Dept Radiol, Los Angeles, CA 90027 USA
[2] Childrens Hosp Los Angeles, Dept Orthopaed Surg, Los Angeles, CA 90027 USA
[3] Childrens Hosp Los Angeles, Dept Neurol, Los Angeles, CA 90027 USA
[4] Univ So Calif, Viterbi Sch Engn, Dept Elect Engn, Los Angeles, CA USA
基金
美国国家卫生研究院;
关键词
diffusion-tensor imaging; fat quantification; MRI; muscle; DUCHENNE MUSCULAR-DYSTROPHY; MOUSE SKELETAL-MUSCLE; THIGH MUSCLES; REPRODUCIBILITY; INFILTRATION; TRACTOGRAPHY; DIXON;
D O I
10.2214/AJR.13.11081
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to assess the repeatability of water-fat MRI and diffusion-tensor imaging (DTI) as quantitative biomarkers of pediatric lower extremity skeletal muscle. SUBJECTS AND METHODS. MRI at 3 T of a randomly selected thigh and lower leg of seven healthy children was studied using water-fat separation and DTI techniques. Muscle-fat fraction, apparent diffusion coefficient (ADC), and fractional anisotropy (FA) values were calculated. Test-retest and interrater repeatability were assessed by calculating the Pearson correlation coefficient, intraclass correlation coefficient, and Bland-Altman analysis. RESULTS. Bland-Altman plots show that the mean difference between test-retest and interrater measurements of muscle-fat fraction, ADC, and FA was near 0. The correlation coefficients and intraclass correlation coefficients were all between 0.88 and 0.99 (p < 0.05), suggesting excellent reliability of the measurements. Muscle-fat fraction measurements from water-fat MRI exhibited the highest intraclass correlation coefficient. Interrater agreement was consistently better than test-retest comparisons. CONCLUSION. Water-fat MRI and DTI measurements in lower extremity skeletal muscles are objective repeatable biomarkers in children. This knowledge should aid in the understanding of the number of participants needed in clinical trials when using these determinations as an outcome measure to noninvasively monitor neuromuscular disease.
引用
收藏
页码:W567 / W573
页数:7
相关论文
共 27 条
[1]   Diffusion-tensor MRI: theory, experimental design and data analysis - a technical review [J].
Basser, PJ ;
Jones, DK .
NMR IN BIOMEDICINE, 2002, 15 (7-8) :456-467
[2]   Longitudinal changes in intermuscular fat volume and quadriceps muscle volume in the thighs of women with knee osteoarthritis [J].
Beattie, Karen A. ;
MacIntyre, Norma J. ;
Ramadan, Khaled ;
Inglis, Dean ;
Maly, Monica R. .
ARTHRITIS CARE & RESEARCH, 2012, 64 (01) :22-29
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Fat and Water Magnetic Resonance Imaging [J].
Bley, Thorsten A. ;
Wieben, Oliver ;
Francois, Christopher J. ;
Brittain, Jean H. ;
Reeder, Scott B. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (01) :4-18
[5]   Diffusion tensor imaging of the brain in a healthy adult population: Normative values and measurement reproducibility at 3 T and 1.5 T [J].
Brander, Antti ;
Kataja, Anneli ;
Saastamoinen, Antti ;
Ryymin, Pertti ;
Huhtala, Heini ;
Ohman, Juha ;
Soimakallio, Seppo ;
Dastidar, Prasun .
ACTA RADIOLOGICA, 2010, 51 (07) :800-807
[6]   In vivo MR tractography of thigh muscles using diffusion imaging: initial results [J].
Budzik, J. F. ;
Le Thuc, V. ;
Demondion, X. ;
Morel, M. ;
Chechin, D. ;
Cotten, A. .
EUROPEAN RADIOLOGY, 2007, 17 (12) :3079-3085
[7]   SIMPLE PROTON SPECTROSCOPIC IMAGING [J].
DIXON, WT .
RADIOLOGY, 1984, 153 (01) :189-194
[8]   NEUROMUSCULAR DISEASES - EVALUATION WITH HIGH-FREQUENCY SONOGRAPHY [J].
DOCK, W ;
HAPPAK, W ;
GRABENWOGER, F ;
TOIFL, K ;
BITTNER, R ;
GRUBER, H .
RADIOLOGY, 1990, 177 (03) :825-828
[9]   Dual-Echo Dixon Imaging with Flexible Choice of Echo Times [J].
Eggers, Holger ;
Brendel, Bernhard ;
Duijndam, Adri ;
Herigault, Gwenael .
MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (01) :96-107
[10]  
Fleiss J., 1986, Reliability of measurement: the design and analysis of clinical experiments