Feasibility of Long-Term Closed-Loop Control: A Multicenter 6-Month Trial of 24/7 Automated Insulin Delivery

被引:109
作者
Kovatchev, Boris [1 ]
Cheng, Peiyao [2 ]
Anderson, Stacey M. [1 ]
Pinsker, Jordan E. [3 ]
Boscari, Federico [4 ]
Buckingham, Bruce A. [5 ]
Doyle, Francis J., III [6 ,7 ]
Hood, Korey K. [5 ]
Brown, Sue A. [1 ]
Breton, Marc D. [1 ]
Chernavvsky, Daniel [1 ]
Bevier, Wendy C. [3 ]
Bradley, Paige K. [3 ]
Bruttomesso, Daniela [4 ]
Del Favero, Simone [4 ]
Calore, Roberta [4 ]
Cobelli, Claudio [4 ]
Avogaro, Angelo [4 ]
Ly, Trang T. [5 ]
Shanmugham, Satya [5 ]
Dassau, Eyal [6 ,7 ]
Kollman, Craig [2 ]
Lum, John W. [2 ]
Beck, Roy W. [2 ]
机构
[1] Univ Virginia, Ctr Diabet Technol, 560 Ray C Hunt DR,3rd Floor, Charlottesville, VA 22903 USA
[2] Jaeb Ctr Hlth Res, Tampa, FL USA
[3] William Sansum Diabet Ctr, Santa Barbara, CA USA
[4] Univ Padua, Padua, Italy
[5] Stanford Univ, Dept Pediat, Sch Med, Div Pediat Endocrinol & Diabet, Stanford, CA 94305 USA
[6] Univ Calif Santa Barbara, Dept Chem Engn, Santa Barbara, CA 93106 USA
[7] Harvard Univ, Harvard John A Paulson Sch Engn & Appl Sci, Cambridge, MA 02138 USA
关键词
Insulin pump therapy; Continuous glucose monitoring (CGM); Automated insulin delivery ( AID); Closed-loop control; Artificial pancreas; RANDOMIZED CROSSOVER TRIAL; FREE-LIVING CONDITIONS; ARTIFICIAL PANCREAS; GLUCOSE CONTROL; CLINICAL-TRIAL; HOME-USE; ADULTS; NIGHT; SYSTEM; ALGORITHMS;
D O I
10.1089/dia.2016.0333
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: In the past few years, the artificial pancreas-the commonly accepted term for closed-loop control (CLC) of blood glucose in diabetes-has become a hot topic in research and technology development. In the summer of 2014, we initiated a 6-month trial evaluating the safety of 24/7 CLC during free-living conditions. Research Design and Methods: Following an initial 1-month Phase 1, 14 individuals (10 males/4 females) with type 1 diabetes at three clinical centers in the United States and one in Italy continued with a 5-month Phase 2, which included 24/7 CLC using the wireless portable Diabetes Assistant (DiAs) developed at the University of Virginia Center for Diabetes Technology. Median subject characteristics were age 45 years, duration of diabetes 27 years, total daily insulin 0.53 U/kg/day, and baseline HbA1c 7.2% (55 mmol/mol). Results: Compared with the baseline observation period, the frequency of hypoglycemia below 3.9 mmol/L during the last 3 months of CLC was lower: 4.1% versus 1.3%, P < 0.001. This was accompanied by a downward trend in HbA1c from 7.2% (55 mmol/mol) to 7.0% (53 mmol/mol) at 6 months. HbA1c improvement was correlated with system use (Spearman r = 0.55). The user experience was favorable with identified benefit particularly at night and overall trust in the system. There were no serious adverse events, severe hypoglycemia, or diabetic ketoacidosis. Conclusion: We conclude that CLC technology has matured and is safe for prolonged use in patients' natural environment. Based on these promising results, a large randomized trial is warranted to assess long-term CLC efficacy and safety.
引用
收藏
页码:18 / +
页数:8
相关论文
共 34 条
[1]   Multinational Home Use of Closed-Loop Control Is Safe and Effective [J].
Anderson, Stacey M. ;
Raghinaru, Dan ;
Pinsker, Jordan E. ;
Boscari, Federico ;
Renard, Eric ;
Buckingham, Bruce A. ;
Nimri, Revital ;
Doyle, Francis J., III ;
Brown, Sue A. ;
Keith-Hynes, Patrick ;
Breton, Marc D. ;
Chernavvsky, Daniel ;
Bevier, Wendy C. ;
Bradley, Paige K. ;
Bruttomesso, Daniela ;
Del Favero, Simone ;
Calore, Roberta ;
Cobelli, Claudio ;
Avogaro, Angelo ;
Farret, Anne ;
Place, Jerome ;
Ly, Trang T. ;
Shanmugham, Satya ;
Phillip, Moshe ;
Dassau, Eyal ;
Dasanayake, Isuru S. ;
Kollman, Craig ;
Lum, John W. ;
Beck, Roy W. ;
Kovatchev, Boris .
DIABETES CARE, 2016, 39 (07) :1143-1150
[2]   MD-Logic Artificial Pancreas System A pilot study in adults with type 1 diabetes [J].
Atlas, Eran ;
Nimri, Revital ;
Miller, Shahar ;
Grunberg, Eli A. ;
Phillip, Moshe .
DIABETES CARE, 2010, 33 (05) :1072-1076
[3]   Safety of a Hybrid Closed-Loop Insulin Delivery System in Patients With Type 1 Diabetes [J].
Bergenstal, Richard M. ;
Garg, Satish ;
Weinzimer, Stuart A. ;
Buckingham, Bruce A. ;
Bode, Bruce W. ;
Tamborlane, William V. ;
Kaufman, Francine R. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2016, 316 (13) :1407-1408
[4]   Fully Integrated Artificial Pancreas in Type 1 Diabetes: Modular Closed-Loop Glucose Control Maintains Near Normoglycemia [J].
Breton, Marc ;
Farret, Anne ;
Bruttomesso, Daniela ;
Anderson, Stacey ;
Magni, Lalo ;
Patek, Stephen ;
Man, Chiara Dalla ;
Place, Jerome ;
Demartini, Susan ;
Del Favero, Simone ;
Toffanin, Chiara ;
Hughes-Karvetski, Colleen ;
Dassau, Eyal ;
Zisser, Howard ;
Doyle, Francis J., III ;
De Nicolao, Giuseppe ;
Avogaro, Angelo ;
Cobelli, Claudio ;
Renard, Eric ;
Kovatchev, Boris .
DIABETES, 2012, 61 (09) :2230-2237
[5]   Multinight "Bedside" Closed-Loop Control for Patients with Type 1 Diabetes [J].
Brown, Sue A. ;
Kovatchev, Boris P. ;
Breton, Marc D. ;
Anderson, Stacey M. ;
Keith-Hynes, Patrick ;
Patek, Stephen D. ;
Jiang, Boyi ;
Ben Brahim, Najib ;
Vereshchetin, Paul ;
Bruttomesso, Daniela ;
Avogaro, Angelo ;
Del Favero, Simone ;
Boscari, Federico ;
Galasso, Silvia ;
Visentin, Roberto ;
Monaro, Marco ;
Cobelli, Claudio .
DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 (03) :203-209
[6]  
Clarke William L, 2009, J Diabetes Sci Technol, V3, P1031
[7]   MEDICINE A Pancreas in a Box [J].
Clery, Daniel .
SCIENCE, 2014, 343 (6167) :133-135
[8]   The artificial pancreas: a digital-age treatment for diabetes [J].
Cobelli, Claudio ;
Renard, Eric ;
Kovatchev, Boris .
LANCET DIABETES & ENDOCRINOLOGY, 2014, 2 (09) :679-681
[9]   Pilot Studies of Wearable Outpatient Artificial Pancreas in Type 1 Diabetes [J].
Cobelli, Claudio ;
Renard, Eric ;
Kovatchev, Boris P. ;
Keith-Hynes, Patrick ;
Ben Brahim, Najib ;
Place, Jerome ;
Del Favero, Simone ;
Breton, Marc ;
Farret, Anne ;
Bruttomesso, Daniela ;
Dassau, Eyal ;
Zisser, Howard ;
Doyle, Francis J., III ;
Patek, Stephen D. ;
Avogaro, Angelo .
DIABETES CARE, 2012, 35 (09) :E65-E67
[10]   Adjustment of Open-Loop Settings to Improve Closed-Loop Results in Type 1 Diabetes: A Multicenter Randomized Trial [J].
Dassau, Eyal ;
Brown, Sue A. ;
Basu, Ananda ;
Pinsker, Jordan E. ;
Kudva, Yogish C. ;
Gondhalekar, Ravi ;
Patek, Steve ;
Lv, Dayu ;
Schiavon, Michele ;
Lee, Joon Bok ;
Man, Chiara Dalla ;
Hinshaw, Ling ;
Castorino, Kristin ;
Mallad, Ashwini ;
Dadlani, Vikash ;
McCrady-Spitzer, Shelly K. ;
McElwee-Malloy, Molly ;
Wakeman, Christian A. ;
Bevier, Wendy C. ;
Bradley, Paige K. ;
Kovatchev, Boris ;
Cobelli, Claudio ;
Zisser, Howard C. ;
Doyle, Francis J., III .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2015, 100 (10) :3878-3886