Cyclic fatigue resistance of ProTaper Next nickel-titanium rotary files

被引:71
作者
Elnaghy, A. M. [1 ]
机构
[1] Mansoura Univ, Fac Dent, Dept Conservat Dent & Endodont, Mansoura 35516, Egypt
关键词
cyclic fatigue; M-Wire; nickel-titanium files; ProTaper Next; ENDODONTIC INSTRUMENTS; METALLURGICAL CHARACTERIZATION; BENDING PROPERTIES; CANAL PREPARATIONS; ENGINE-DRIVEN; SHAPE-MEMORY; CLINICAL-USE; ROOT CANALS;
D O I
10.1111/iej.12244
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
AimTo compare the cyclic fatigue resistance of ProTaper Next files (PTN; Dentsply Maillefer, Ballaigues, Switzerland) with Twisted Files (TF; SybronEndo, Orange, CA, USA), HyFlex CM (HF; ColteneEndo/Whaledent, Inc, Cuyahoga Falls, OH, USA) and ProTaper Universal (PT; Dentsply Maillefer). MethodologySize 25, .06 taper for PTN X2, TF, HF and PT F1 size 20, .07 taper were rotated in simulated canals until failure, and the number of cycles to failure (NCF) was recorded to evaluate their cyclic fatigue resistance. A scanning electron microscope was used to characterize the topographic features of the fracture surfaces of broken files. The data of the NCF and fragment length values were analysed statistically using one-way analysis of variance and Tukey post hoc tests. Statistical significance level was set at P<0.05. ResultsTwisted Files had a significantly higher resistance to cyclic fatigue than the other instruments (P<0.05). No significant difference was found in NCF between PTN and HF (P>0.05); however, there was a significant difference (P<0.05) of both these systems with PT, which exhibited the lowest mean NCF. The ranking in the NCF values was: TF>PTN>HF>PT. The fracture cross-sections of all brands revealed similar fractographic features, including crack origins, fatigue zone and an overload fast fracture zone. ConclusionsThe new ProTaper Next had greater resistance to cyclic fatigue compared with ProTaper and HyFlex CM but not the Twisted Files.
引用
收藏
页码:1034 / 1039
页数:6
相关论文
共 36 条
[21]   Cyclic fatigue of protaper instruments [J].
Pereira Lopes, Helio ;
Lima Moreira, Edson Jorge ;
Nelson Elias, Carlos ;
Andriola de Almeida, Renata ;
Schultz Neves, Monica .
JOURNAL OF ENDODONTICS, 2007, 33 (01) :55-57
[22]   An in vitro assessment of the physical properties of novel Hyflex nickel-titanium rotary instruments [J].
Peters, O. A. ;
Gluskin, A. K. ;
Weiss, R. A. ;
Han, J. T. .
INTERNATIONAL ENDODONTIC JOURNAL, 2012, 45 (11) :1027-1034
[23]   A comparison of cyclic fatigue between used and new Mtwo Ni-Ti rotary instruments [J].
Plotino, G. ;
Grande, N. M. ;
Sorci, E. ;
Malagnino, V. A. ;
Somma, F. .
INTERNATIONAL ENDODONTIC JOURNAL, 2006, 39 (09) :716-723
[24]   Cyclic fatigue testing of nickel-titanium endodontic instruments [J].
Pruett, JP ;
Clement, DJ ;
Carnes, DL .
JOURNAL OF ENDODONTICS, 1997, 23 (02) :77-85
[25]   Defects in rotary nickel-titanium files after clinical use [J].
Sattapan, B ;
Nervo, GJ ;
Palamara, JEA ;
Messer, HH .
JOURNAL OF ENDODONTICS, 2000, 26 (03) :161-165
[26]   COMPARISON OF CANAL PREPARATIONS IN STRAIGHT AND CURVED ROOT CANALS [J].
SCHNEIDER, SW .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1971, 32 (02) :271-+
[27]   Current Challenges and Concepts of the Thermomechanical Treatment of Nickel-Titanium Instruments [J].
Shen, Ya ;
Zhou, Hui-min ;
Zheng, Yu-feng ;
Peng, Bin ;
Haapasalo, Markus .
JOURNAL OF ENDODONTICS, 2013, 39 (02) :163-172
[28]   Metallurgical Characterization of Controlled Memory Wire Nickel-Titanium Rotary Instruments [J].
Shen, Ya ;
Zhou, Hui-min ;
Zheng, Yu-feng ;
Campbell, Les ;
Peng, Bin ;
Haapasalo, Markus .
JOURNAL OF ENDODONTICS, 2011, 37 (11) :1566-1571
[29]   Fatigue Testing of Controlled Memory Wire Nickel-Titanium Rotary Instruments [J].
Shen, Ya ;
Qian, Wei ;
Abtin, Houman ;
Gao, Yuan ;
Haapasalo, Markus .
JOURNAL OF ENDODONTICS, 2011, 37 (07) :997-1001
[30]  
Simon S, 2008, DENT UPDATE, V35, P5