A comparative study of capacitive immunosensors based on self-assembled monolayers formed from thiourea, thioctic acid, and 3-mercaptopropionic acid

被引:110
作者
Limbut, Warakorn
Kanatharana, Proespichaya
Mattiasson, Bo
Asawatreratanakul, Punnee
Thavarungkul, Panote [1 ]
机构
[1] Prince Songkla Univ, Biophys Res Unit, Hat Yai 90112, Songkhla, Thailand
[2] Prince Songkla Univ, Dept Chem, Fac Sci, Hat Yai 90112, Songkhla, Thailand
[3] Lund Univ, Ctr Chem & Chem Engn, Dept Biotechnol, S-22100 Lund, Sweden
[4] Prince Songkla Univ, Fac Sci, Dept Biochem, Hat Yai 90112, Songkhla, Thailand
[5] Prince Songkla Univ, Fac Sci, Dept Phys, Hat Yai 90112, Songkhla, Thailand
关键词
thiourea; capacitive immunosensor; thioctic acid; 3-mercaptopropionic acid; self-assembled monolayer; alpha-fetoprotein;
D O I
10.1016/j.bios.2005.12.025
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A procedure was developed for the covalent coupling of anti-alpha-fetoprotein antibody (anti-AFP) to a gold surface modified with a self-assembled monolayer (SAM) of thiourea (TU). The performance of the SAM-antibody layer was compared to those of similar layers based on thioctic acid (TA) and 3-mercaptopropionic acid (MPA) by using flow injection capacitive immunosensor system. Covalent coupling of anti-AFP on self-assembled thiourea monolayer (SATUM) modified gold electrode can be used to detect alpha-fetoprotein with high efficiency, similar sensitivity, the same linear range (0.01-10 mu g l(-1)) and detection limit (10ng l(-1)) as those obtained from sensors based on self-assembled thioctic acid monolayer (SATAM) and self-assembled 3-mercaptopropionic acid monolayer (SAMPAM). The system is specific for alpha-fetoprotein and can be regenerated and reused up to 48 times. Therefore, self-assembled monolayer using thiourea which is cheaper than thioctic acid and 3-mercaptopropionic acid is a good alternative for biosensor applications when SAMs are used. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:233 / 240
页数:8
相关论文
共 50 条
[41]   A novel immunosensor based on immobilization of hepatitis B surface antibody on platinum electrode modified colloidal gold and polyvinyl butyral as matrices via electrochemical impedance spectroscopy [J].
Tang, DP ;
Yuan, R ;
Chai, YQ ;
Dai, JY ;
Zhong, X ;
Liu, Y .
BIOELECTROCHEMISTRY, 2004, 65 (01) :15-22
[42]  
Taylor R., 1991, PROTEIN IMMOBILIZATI
[43]   ANTIBODY-BASED AND RECEPTOR-BASED BIOSENSORS FOR DETECTION AND PROCESS-CONTROL [J].
TAYLOR, RF ;
MARENCHIC, IG ;
SPENCER, RH .
ANALYTICA CHIMICA ACTA, 1991, 249 (01) :67-70
[44]   An innovative thiourea gold leaching process [J].
Ubaldini, S ;
Fornari, P ;
Massidda, R ;
Abbruzzese, C .
HYDROMETALLURGY, 1998, 48 (01) :113-124
[45]   Sulfur based self-assembled monolayers (SAM's) on piezoelectric crystals for immunosensor development [J].
Vaughan, RD ;
O'Sullivan, CK ;
Guilbault, GG .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (1-2) :54-57
[46]  
Wadu-Mesthrige K, 2000, SCANNING, V22, P380
[47]   ELECTROCHEMICALLY INDUCED TRANSFORMATIONS OF MONOLAYERS FORMED BY SELF-ASSEMBLY OF MERCAPTOETHANOL AT GOLD [J].
WEISSHAAR, DE ;
WALCZAK, MM ;
PORTER, MD .
LANGMUIR, 1993, 9 (01) :323-329
[48]   THERMODYNAMICALLY CONTROLLED ELECTROCHEMICAL FORMATION OF THIOLATE MONOLAYERS AT GOLD - CHARACTERIZATION AND COMPARISON TO SELF-ASSEMBLED ANALOGS [J].
WEISSHAAR, DE ;
LAMP, BD ;
PORTER, MD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (14) :5860-5862
[49]   Development of a conductivity-based immunosensor for sensitive detection of methamphetamine (stimulant drug) in human urine [J].
Yagiuda, K ;
Hemmi, A ;
Ito, S ;
Asano, Y ;
Fushinuki, Y ;
Chen, CY ;
Karube, I .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (08) :703-707
[50]   ANALYTICAL APPLICATION OF SELF-ASSEMBLED MONOLAYERS ON GOLD ELECTRODES - CRITICAL IMPORTANCE OF SURFACE PRETREATMENT [J].
YANG, Z ;
GONZALEZCORTES, A ;
JOURQUIN, G ;
VIRE, JC ;
KAUFFMANN, JM ;
DELPLANCKE, JL .
BIOSENSORS & BIOELECTRONICS, 1995, 10 (9-10) :789-795