Nonnephrotoxic, dynamic, contrast enhanced magnetic resonance urography: Use in nephrology and urology

被引:19
作者
Farres, MT
Gattegno, B
Ronco, P
Flahault, A
Paula-Souza, R
Bigot, JM
机构
[1] Assistance Publ Hop Paris, Hop Tenon, Dept Radiol, F-75970 Paris, France
[2] Assistance Publ Hop Paris, Hop Tenon, Dept Urol, F-75970 Paris, France
[3] Assistance Publ Hop Paris, Hop Tenon, Dept Nephrol, F-75970 Paris, France
[4] Assistance Publ Hop Paris, Hop Tenon, Dept Stat, F-75970 Paris, France
关键词
magnetic resonance imaging; urography; gadolinium; contrast media; urinary tract;
D O I
10.1016/S0022-5347(05)67720-8
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We assessed the value of breath-hold, gadolinium (Gd) enhanced magnetic resonance urography for diagnosing urinary tract disease. Materials and Methods: Dynamic magnetic resonance urography was performed in 38 consecutive patients presenting with urological disease in whom excretory urography was contraindicated. Renal function was impaired in 18 cases with a serum creatinine of 140 to 400 mu mol./l. Fast spoiled, gradient echo sequences were acquired during breath-holding 5, 10 and 15 minutes after intravenous injection of 10 ml. of a Gd chelate. Opacification of the collecting system was evaluated using a scale of 0 to 3. Diagnostic value of the examinations was also analyzed. Results: Dynamic magnetic resonance urography was sufficient for making the diagnosis in 95% of cases. We identified 71 pathological findings and the surgical anastomosis was always well visualized. Mean image quality score was 2.34 points for renal calices, 2.86 for renal pelves and 2.48 for ureters. Image quality significantly improved after injecting a diuretic. Conclusions: Gd enhanced magnetic resonance urography provides quality dynamic imaging of the urinary tract. It is a new approach for diagnosing urinary tract disorders in patients in whom excretory urography should be avoided.
引用
收藏
页码:1191 / 1196
页数:6
相关论文
共 11 条
[1]   Breath-hold MR urography using the HASTE technique [J].
Aerts, P ;
VanHoe, L ;
Bosmans, H ;
Oyen, R ;
Marchal, G ;
Baert, AL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (03) :543-545
[2]  
Altman D, 1991, PRACTICAL STAT MED R, P404
[3]   Systemic gadolinium toxicity in patients with renal insufficiency and renal failure: Retrospective analysis of an initial experience [J].
Arsenault, TM ;
King, BF ;
Marsh, JW ;
Goodman, JA ;
Weaver, AL ;
Wood, CP ;
Ehman, RL .
MAYO CLINIC PROCEEDINGS, 1996, 71 (12) :1150-1154
[4]   ABDOMINAL-AORTA AND RENAL-ARTERY STENOSIS - EVALUATION WITH MR ANGIOGRAPHY [J].
KIM, D ;
EDELMAN, RR ;
KENT, KC ;
PORTER, DH ;
SKILLMAN, JJ .
RADIOLOGY, 1990, 174 (03) :727-731
[5]   Magnetic resonance urography by breath-hold contrast-enhanced three-dimensional FISP [J].
Li, W ;
Chavez, D ;
Edelman, RR ;
Prasad, PV .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (02) :309-311
[6]   MR urography in the diagnosis of urinary tract obstruction [J].
Louca, G ;
Liberopoulos, K ;
Fidas, A ;
Nikolakopoulou, Z ;
Lykourinas, M ;
Strigaris, K .
EUROPEAN UROLOGY, 1999, 35 (02) :102-108
[7]   Gadolinium-enhanced excretory MR urography after low-dose diuretic injection:: Comparison with conventional excretory urography [J].
Nolte-Ernsting, CCA ;
Bücker, A ;
Adam, GB ;
Neuerburg, JM ;
Jung, P ;
Hunter, DW ;
Jakse, G ;
Günther, RW .
RADIOLOGY, 1998, 209 (01) :147-157
[8]   Visualization of urinary tract dilatation: value of single-shot MR urography [J].
Reuther, G ;
Kiefer, B ;
Wandl, E .
EUROPEAN RADIOLOGY, 1997, 7 (08) :1276-1281
[9]   PREVALENCE OF NOCTURNAL OXYGEN DESATURATION IN PATIENTS ADMITTED TO A GERIATRIC REHABILITATION UNIT [J].
ROTH, T ;
HOLTMANN, BJ .
JOURNAL OF SLEEP RESEARCH, 1995, 4 :194-196
[10]   UROGRAPHY [J].
SAXTON, HM .
BRITISH JOURNAL OF RADIOLOGY, 1969, 42 (497) :321-&