In Vitro, Time-Resolved PIV Comparison of the Effect of Stent Design on Wall Shear Stress

被引:52
作者
Charonko, John [1 ]
Karri, Satyaprakash [1 ]
Schmieg, Jaime [1 ]
Prabhu, Santosh [2 ]
Vlachos, Pavlos [1 ]
机构
[1] Virginia Tech, Blacksburg, VA 24061 USA
[2] Abbott Vasc, Santa Clara, CA 95054 USA
基金
美国国家科学基金会;
关键词
Coronary arteries; Blood flow; Phase offset; Oscillatory shear index; Drug-eluting stent; Bare metal stent; Endothelial cells; CORONARY-ARTERY-DISEASE; NEWTONIAN BLOOD-FLOW; FLUID-DYNAMICS; IMPLANTATION; MODEL; RESTENOSIS; PLACEMENT; IMMEDIATE; HUMANS;
D O I
10.1007/s10439-009-9697-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The effect of stent design on wall shear stress (WSS) and oscillatory shear index (OSI) was studied in vitro using time-resolved digital particle image velocimetry (DPIV). Four drug-eluting stents [XIENCE V-A (R) (Abbott Vascular), TAXUS(A (R)) Libert,(A (R)) (Boston Scientific), Endeavor(A (R)) (Medtronic), and Cypher(A (R)) (J&J Cordis)] and a bare-metal stent [VISIONA (R) (Abbott Vascular)] were implanted into compliant vessel models, and the flow was measured in physiologically accurate coronary conditions featuring reversal and realistic offsets between pressure and flowrate. DPIV measurements were made at three locations under two different flow rates (resting: Re = 160, f = 70 bpm and exercise: Re = 300, f = 120 bpm). It was observed that design substantially affected the WSS experienced at the vessel walls. Averaged values between struts ranged from 2.05 dynes/cm(2) (Cypher(A (R))) to 8.52 dynes/cm(2) (XIENCE V-A (R)) in resting conditions, and from 3.72 dynes/cm(2) (Cypher(A (R))) to 14.66 dynes/cm(2) (VISIONA (R)) for the exercise state. Within the stent, the WSS dropped and the OSI increased immediately distal to each strut. In addition, an inverse correlation between average WSS and OSI existed. Comparisons with recently published results from animal studies show strong correlation between the measured WSS and observed endothelial cell coverage. These results suggest the importance of stent design on the WSS experienced by endothelial cells in coronary arteries.
引用
收藏
页码:1310 / 1321
页数:12
相关论文
共 49 条
[1]  
ABIVEN C, 2002, 2002 P ASME IMECE NE
[2]   Twenty years of particle image velocimetry [J].
Adrian, RJ .
EXPERIMENTS IN FLUIDS, 2005, 39 (02) :159-169
[3]   Immediate and long-term outcome of intracoronary stent implantation for true bifurcation lesions [J].
Al Suwaidi, J ;
Berger, PB ;
Rihal, CS ;
Garratt, KN ;
Bell, MR ;
Ting, HH ;
Bresnahan, JF ;
Grill, DE ;
Holmes, DR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (04) :929-936
[4]   Effects of different stent designs on local hemodynamics in stented arteries [J].
Balossino, Rossella ;
Gervaso, Francesca ;
Migliavacca, Francesco ;
Dubini, Gabriele .
JOURNAL OF BIOMECHANICS, 2008, 41 (05) :1053-1061
[5]   Experimental study of laminar blood flow through an artery treated by a stent implantation: characterisation of intra-stent wall shear stress [J].
Benard, N ;
Coisne, D ;
Donal, E ;
Perrault, R .
JOURNAL OF BIOMECHANICS, 2003, 36 (07) :991-998
[6]  
Berry J.L., 1997, Journal of Vascular Investigation, V2, P63
[7]   Experimental and computational flow evaluation of coronary stents [J].
Berry, JL ;
Santamarina, A ;
Moore, JE ;
Roychowdhury, S ;
Routh, WD .
ANNALS OF BIOMEDICAL ENGINEERING, 2000, 28 (04) :386-398
[8]   A Scaling Parameter for Predicting Pressure Wave Reflection in Stented Arteries [J].
Charonko, John J. ;
Ragab, Saad A. ;
Vlachos, Pavlos P. .
JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2009, 3 (01)
[9]   A model for studying the effect of shear stress on interactions between vascular endothelial cells and smooth muscle cells [J].
Chiu, JJ ;
Chen, LJ ;
Chen, CN ;
Lee, PL ;
Lee, CI .
JOURNAL OF BIOMECHANICS, 2004, 37 (04) :531-539
[10]   Stented artery flow patterns and their effects on the artery wall [J].
Duraiswamy, Nandim ;
Schoephoerster, Richard T. ;
Moreno, Michael R. ;
Moore, James E., Jr. .
ANNUAL REVIEW OF FLUID MECHANICS, 2007, 39 :357-382