Adjustable continence therapy (ProACT) for the treatment of male stress urinary incontinence: A systematic review and meta-analysis

被引:27
作者
Larson, Troy [1 ]
Jhaveri, Hasan [1 ]
Yeung, Lawrence L. [1 ]
机构
[1] Univ Florida, Coll Med, Dept Urol, Gainesville, FL USA
关键词
minimally invasive therapy; postprostatectomy; stress urinary incontinence; TRANSOBTURATOR MALE SYSTEM; MALE SLING FAILURE; RADICAL PROSTATECTOMY; POSTPROSTATECTOMY INCONTINENCE; SURGICAL-TREATMENT; DEVICE; IMPLANTATION; SPHINCTER; BALLOONS; COMPLICATIONS;
D O I
10.1002/nau.24135
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Aims First, to evaluate the efficacy of adjustable balloon devices or adjustable continence therapy (ProACT) in the treatment for male stress urinary incontinence (SUI). Second, to investigate the safety profile and rates of adverse events associated with the implantation of adjustable balloon devices. Method A review of the literature was performed by searching the PubMed database with the most applicable search terms. We narrowed included studies with adult male patients with SUI; outcomes included pads or pad weight per day and quality of life (QOL) questionnaires, as well as safety outcomes. Results In total, 19 studies were included with a total of 1264 patients and 4517 patient-years of follow-up data (mean follow-up time 3.6 years). ProACT implantation resulted in an incontinence QOL improvement of 30.8 points from baseline. At baseline, patients on average were using 4.0 pads per day (PPD) (95% confidence interval [CI]: 2.6-5.4), which was reduced to an average of 1.1 PPD (95% CI: 0.5-1.7) after ProACT implantation. The number of patients that were considered "dry" was 60.2% (95% CI: 54.2%-65.9%) and the number of patients who were found to be either "dry" or improved greater than 50% was 81.9% (95% CI: 74%-87.8%). Conclusions Implantation of adjustable balloon devices is efficacious and safe for the treatment of male SUI. Given the minimal invasiveness of the therapy, adjustable balloon devices may be a serious option as a first-line treatment in nonirradiated patients with SUI who are not ideal candidates for the artificial urinary sphincter.
引用
收藏
页码:2051 / 2059
页数:9
相关论文
共 39 条
[1]   Sequential treatment with ProACT™ device implantation after male sling failure for male urinary incontinence [J].
Baron, M. G. ;
Delcourt, C. ;
Nouhaud, F. -X. ;
Gillibert, A. ;
Pfister, C. ;
Grise, P. ;
Cornu, J. -N. .
PROGRES EN UROLOGIE, 2017, 27 (17) :1098-1103
[2]   Adjustable continence therapy (ProACT) and bone anchored male sling: Comparison of two new treatments of post prostatectomy incontinence [J].
Crivellaro, Simone ;
Singla, Ajay ;
Aggarwal, Neelesh ;
Frea, Bruno ;
Kocjancic, Ervin .
INTERNATIONAL JOURNAL OF UROLOGY, 2008, 15 (10) :910-914
[3]   Systematic review of surgical treatment of post radical prostatectomy stress urinary incontinence [J].
Crivellaro, Simone ;
Morlacco, Alessandro ;
Bodo, Giovanni ;
Agro', Enrico Finazzi ;
Gozzi, Christian ;
Pistolesi, Donatella ;
Del Popolo, Giulio ;
Ficarra, Vincenzo .
NEUROUROLOGY AND URODYNAMICS, 2016, 35 (08) :875-881
[4]   Geometrical Stepper-Guided Navigation System for ProACT Implant under Transrectal Ultrasound Control: Preliminary Data [J].
Crivellaro, Simone ;
Tosco, Lorenzo ;
Palazzetti, Anna ;
Abbinante, Maria ;
Martinez, Guillermo ;
Kocjancic, Ervin ;
Frea, Bruno .
UROLOGIA INTERNATIONALIS, 2012, 89 (04) :473-479
[5]  
Emmanuel A., 2017, Incontinence
[6]   Surgical Treatment of Neurogenic Stress Urinary Incontinence: A Systematic Review of Quality Assessment and Surgical Outcomes [J].
Farag, Fawzy ;
Koens, Martin ;
Sievert, Karl-Dietrich ;
De Ridder, Dirk ;
Feitz, Wout ;
Heesakkers, John .
NEUROUROLOGY AND URODYNAMICS, 2016, 35 (01) :21-25
[7]   Long-term outcome of the adjustable transobturator male system (ATOMS): results of a European multicentre study [J].
Friedl, Alexander ;
Muehlstaedt, Sandra ;
Zachoval, Roman ;
Giammo, Alessandro ;
Kivaranovic, Danijel ;
Rom, Maximilian ;
Fornara, Paolo ;
Broessner, Clemens .
BJU INTERNATIONAL, 2017, 119 (05) :785-792
[8]   Spiral Multidetector Computerized Tomography Evaluation of Adjustable Continence Therapy Implants [J].
Giammo, Alessandro ;
Bodo, Giovanni ;
Castellano, Silvia ;
Borre, Alda ;
Carone, Roberto .
JOURNAL OF UROLOGY, 2010, 183 (05) :1921-1926
[9]   An adjustable continence therapy device for treating incontinence after prostatectomy: a minimum 2-year follow-up [J].
Gilling, Peter J. ;
Bell, Deborah F. ;
Wilson, Liam C. ;
Westenberg, Andre M. ;
Reuther, Rana ;
Fraundorfer, Mark R. .
BJU INTERNATIONAL, 2008, 102 (10) :1426-1430
[10]   Artificial urinary sphincter for post-prostatectomy incontinence in men who had prior radiotherapy: A risk and outcome analysis [J].
Gomha, MA ;
Boone, TB .
JOURNAL OF UROLOGY, 2002, 167 (02) :591-596