A new approach to detect early or hidden fungal development in indoor environments

被引:7
作者
Anton, Rukshala [1 ]
Moularat, Stephane [1 ]
Robine, Enric [1 ]
机构
[1] CSTB, F-77447 Marne La Vallee 2, France
关键词
Mold detection; Fungal Contamination index; Indoor air quality; Monitoring device; VOC analysis; Sensor array; VOLATILE ORGANIC-COMPOUNDS; ELECTRONIC NOSE; RESPIRATORY-INFECTIONS; HIGH-PERFORMANCE; HOME DAMPNESS; SENSOR ARRAY; IDENTIFICATION; CHROMATOGRAPHY; CONTAMINATION; COLUMNS;
D O I
10.1016/j.chemosphere.2015.06.072
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In addition to the biodegradation problems encountered in buildings, exposure of their occupants to mold is responsible for numerous diseases such as respiratory infections, immediate or delayed allergies and different types of irritations. However, current techniques are unable to detect mold at an early stage of development or hidden contaminants. Moularat et al., in 2008 has established chemical fingerprints of moldy growth from Volatile Organic Compounds (VOCs) arising specifically from fungal metabolism and developed the Fungal Contamination Index (FCI) (Moularat et al., 2008a,b). This index has the advantage of detecting fungal development both reliably and rapidly before any visible signs of contamination could be detected. However, even though the FCI has been widely tested, VOCs' analysis by GC/MS, which is required for index calculation, is incompatible with real-time monitoring strategy for indoor environments. In this context, researches around FCI exploitation have been followed up in order to provide a monitoring device widely deployable which is the result of the miniaturization of an analytical chain for portable, reliable and low-cost applications. This device is based on one hand the selection and concentration of chemical compounds from the sample of interest and on the other hand the development of an array of different conducting polymer based sensors in order to obtain a specific footprint. This fungal contamination detection device was the subject of patent applications by the CSTB. The modularity of the system (ability to vary both the elements of detection polymers and retention time of interest) allows for expansion of its use to other pollutants. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:41 / 49
页数:9
相关论文
共 33 条
[1]  
[Anonymous], NIST 98 MASS SPECTRA
[2]   Development of conducting polymer sensor arrays for wound monitoring [J].
Bailey, Arthur L. R. S. ;
Pisanelli, Anna Maria ;
Persaud, Krishna C. .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 131 (01) :5-9
[3]   Application of electronic nose technology for the detection of fungal contamination in library paper [J].
Canhoto, O ;
Pinzari, F ;
Fanelli, C ;
Magan, N .
INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 2004, 54 (04) :303-309
[4]   Identification of Staphylococcus aureus infections in hospital environment:: electronic nose based approach [J].
Dutta, R ;
Morgan, D ;
Baker, N ;
Gardner, JW ;
Hines, EL .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 109 (02) :355-362
[5]  
Escamilla-Garcia B, 1997, ETIOLOGIE COMP MALAD
[6]   Indoor airborne fungal spores, house dampness and associations with environmental factors and respiratory health in children [J].
Garrett, MH ;
Rayment, PR ;
Hooper, MA ;
Abramson, MJ ;
Hooper, BM .
CLINICAL AND EXPERIMENTAL ALLERGY, 1998, 28 (04) :459-467
[7]   Detection and simultaneous identification of microorganisms from headspace samples using an electronic nose. [J].
Gibson, TD ;
Prosser, O ;
Hulbert, JN ;
Marshall, RW ;
Corcoran, P ;
Lowery, P ;
Ruck-Keene, EA ;
Heron, S .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 44 (1-3) :413-422
[8]   Detection of Serpula lacrymans infestation with a polypyrrole sensor array [J].
Hamilton, S ;
Hepher, MJ ;
Sommerville, J .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (02) :989-997
[9]   Positive associations between respiratory outcomes and fungal index in rural inhabitants of a representative sample of French dwellings [J].
Hulin, M. ;
Moularat, S. ;
Kirchner, S. ;
Robine, E. ;
Mandin, C. ;
Annesi-Maesano, I. .
INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2013, 216 (02) :155-162
[10]   Indoor air pollution and childhood asthma: variations between urban and rural areas [J].
Hulin, M. ;
Caillaud, D. ;
Annesi-Maesano, I. .
INDOOR AIR, 2010, 20 (06) :502-514