Investigation of mass transfer in milli-channels using high-resolution microfocus X-ray imaging

被引:10
作者
Haghnegahdar, Mohammadreza [1 ]
Boden, Stephan [1 ]
Hampel, Uwe [1 ,2 ]
机构
[1] Helmholtz Zentrum Dresden Rossendorf, Inst Fluid Dynam, D-01328 Dresden, Germany
[2] Tech Univ Dresden, AREVA Endowed Chair Imaging Tech Energy & Proc En, D-01062 Dresden, Germany
关键词
Taylor bubble; Mass transfer; Carbon dioxide; X-ray imaging; Milli-channels; CARBON-DIOXIDE BUBBLES; SINGLE BUBBLES; GAS-ABSORPTION; CONTAMINATED WATER; NEWTONIAN LIQUIDS; DISSOLUTION RATE; VERTICAL PIPE; FREE RISE; DOWNWARD; FLOW;
D O I
10.1016/j.ijheatmasstransfer.2015.10.033
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this work, the absorption rate of a single Taylor bubble of carbon dioxide in water was investigated within vertical capillaries using high resolution X-ray imaging. The liquid side mass transfer coefficient was calculated from the changes in the size of the bubble at constant pressure obtained from the high-resolution X-ray images by image processing. The bubbles were continuously monitored by holding the bubble stationary in a downward flow of liquid. The processed images, which give the volume of the bubble with high accuracy as a function of time, were processed to evaluate the liquid side mass transfer coefficient between bubble and liquid using the mass conservation equation. The experiments covered a large range of initial Taylor bubble length varying from 5 to 22 mm. The results show that the measured Sherwood numbers depend strongly on the bubble length and also equivalent diameter, which is the same trend as in previously reported results for larger pipe sizes. However the values of measured Sherwood numbers could not be predicted by available correlations. As a result a new mass transfer coefficient in the form of Sherwood number and as a function of Peclet number as well as the ratio of bubble equivalent diameter to capillary diameter (d(eq)/D) is presented. The proposed correlation is applicable for a large range of the ratio d(ed)/D that varies from 0.8 to 1.6. The average relative error between measured Sherwood number and the one calculated with the new correlation is less than 9.6%. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:653 / 664
页数:12
相关论文
共 50 条
[21]   High-resolution mucociliary transport measurement in live excised large animal trachea using synchrotron X-ray imaging [J].
Donnelley, Martin ;
Morgan, Kaye S. ;
Awadalla, Maged ;
Farrow, Nigel R. ;
Hall, Chris ;
Parsons, David W. .
RESPIRATORY RESEARCH, 2017, 18
[22]   Analysis of high-resolution X-ray imaging of an inertial-confinement-fusion target by using a Fresnel zone plate [J].
Wang Xiao-Fang ;
Wang Jing-Yu .
ACTA PHYSICA SINICA, 2011, 60 (02)
[23]   High-resolution mucociliary transport measurement in live excised large animal trachea using synchrotron X-ray imaging [J].
Martin Donnelley ;
Kaye S. Morgan ;
Maged Awadalla ;
Nigel R. Farrow ;
Chris Hall ;
David W. Parsons .
Respiratory Research, 18
[24]   Demonstration of a high resolution X-ray detector for medical imaging [J].
Morse, Theodore. F. ;
Mostovych, Nicholas ;
Gupta, Rajiv ;
Murphy, Timothy ;
Weber, Peter ;
Cherepy, Nerine ;
Adams, Bernhard ;
Bifano, Thomas ;
Stankus, Brian ;
Akif, Adil ;
Kingon, Angus I. .
RADIATION DETECTORS IN MEDICINE, INDUSTRY, AND NATIONAL SECURITY XIX, 2018, 10763
[25]   Optimization of CMOS active pixels with high signal-to-noise ratio for high-resolution X-ray imaging [J].
Kim, Young Soo ;
Kim, Kwang Hyun ;
Cho, Gyuseong .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01) :248-251
[26]   High-energy, high-resolution x-ray imaging on the Trident short-pulse laser facility [J].
Workman, J. ;
Cobble, J. ;
Flippo, K. ;
Gautier, D. C. ;
Letzring, S. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (10)
[27]   Fast X-Ray Phase-Contrast Imaging Using High Resolution Detector [J].
Wang, Zhentian ;
Huang, Zhifeng ;
Zhang, Li ;
Kang, Kejun ;
Zhu, Peiping .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) :1383-1388
[28]   Bragg magnifier: High-efficiency, high-resolution X-ray detector [J].
Stampanoni, Marco ;
Groso, Amela ;
Borchert, Gunther ;
Abela, Rafael .
SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 :1168-+
[29]   High-resolution X-ray imaging applications of hybrid-pixel photon counting detectors Timepix [J].
Dudak, Jan .
RADIATION MEASUREMENTS, 2020, 137
[30]   High-resolution flexible X-ray luminescence imaging enabled by eco-friendly CuI scintillators [J].
Hong, Zhongzhu ;
Luo, Peifu ;
Wu, Tingting ;
Wu, Qinxia ;
Chen, Xiaoling ;
Yang, Zhijian ;
Dai, Shuheng ;
Jiang, Hao ;
Chen, Qihao ;
Sun, Qiang ;
Xie, Lili .
FRONTIERS IN CHEMISTRY, 2022, 10