Investigation of mass transfer in milli-channels using high-resolution microfocus X-ray imaging

被引:10
作者
Haghnegahdar, Mohammadreza [1 ]
Boden, Stephan [1 ]
Hampel, Uwe [1 ,2 ]
机构
[1] Helmholtz Zentrum Dresden Rossendorf, Inst Fluid Dynam, D-01328 Dresden, Germany
[2] Tech Univ Dresden, AREVA Endowed Chair Imaging Tech Energy & Proc En, D-01062 Dresden, Germany
关键词
Taylor bubble; Mass transfer; Carbon dioxide; X-ray imaging; Milli-channels; CARBON-DIOXIDE BUBBLES; SINGLE BUBBLES; GAS-ABSORPTION; CONTAMINATED WATER; NEWTONIAN LIQUIDS; DISSOLUTION RATE; VERTICAL PIPE; FREE RISE; DOWNWARD; FLOW;
D O I
10.1016/j.ijheatmasstransfer.2015.10.033
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this work, the absorption rate of a single Taylor bubble of carbon dioxide in water was investigated within vertical capillaries using high resolution X-ray imaging. The liquid side mass transfer coefficient was calculated from the changes in the size of the bubble at constant pressure obtained from the high-resolution X-ray images by image processing. The bubbles were continuously monitored by holding the bubble stationary in a downward flow of liquid. The processed images, which give the volume of the bubble with high accuracy as a function of time, were processed to evaluate the liquid side mass transfer coefficient between bubble and liquid using the mass conservation equation. The experiments covered a large range of initial Taylor bubble length varying from 5 to 22 mm. The results show that the measured Sherwood numbers depend strongly on the bubble length and also equivalent diameter, which is the same trend as in previously reported results for larger pipe sizes. However the values of measured Sherwood numbers could not be predicted by available correlations. As a result a new mass transfer coefficient in the form of Sherwood number and as a function of Peclet number as well as the ratio of bubble equivalent diameter to capillary diameter (d(eq)/D) is presented. The proposed correlation is applicable for a large range of the ratio d(ed)/D that varies from 0.8 to 1.6. The average relative error between measured Sherwood number and the one calculated with the new correlation is less than 9.6%. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:653 / 664
页数:12
相关论文
共 50 条
  • [1] Investigation of surfactant effect on the bubble shape and mass transfer in a milli-channel using high-resolution microfocus X-ray imaging
    Haghnegandar, Mohammadreza
    Boden, Stephan
    Hampel, Uwe
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2016, 87 : 184 - 196
  • [2] Measurement of Taylor bubble shape in square channel by microfocus X-ray computed tomography for investigation of mass transfer
    Boden, Stephan
    Haghnegandar, Mohammadreza
    Hampel, Uwe
    FLOW MEASUREMENT AND INSTRUMENTATION, 2017, 53 : 49 - 55
  • [3] EXPERIENCE WITH IMAGING BY USING OF MICROFOCUS X-RAY SOURCE
    Zaprazny, Zdenko
    Korytar, Dusan
    Dubecky, Frantisek
    Ac, Vladimir
    Stachura, Zbigniew
    Lekki, Janusz
    Bielicky, Jakub
    Mudron, Jan
    JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS, 2010, 61 (05): : 287 - 290
  • [4] High-Resolution Neutron and X-Ray Imaging of Granular Materials
    Kim, Felix H.
    Penumadu, Dayakar
    Gregor, Jens
    Kardjilov, Nikolay
    Manke, Ingo
    JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2013, 139 (05) : 715 - 723
  • [5] High-resolution x-ray imaging of extended lasing plasmas
    Forster, E
    Hutcheon, RJ
    Renner, O
    Uschmann, I
    Vollbrecht, M
    Nantel, M
    Klisnick, A
    Jaegle, P
    APPLIED OPTICS, 1997, 36 (04): : 831 - 840
  • [6] High-resolution X-ray diffraction imaging in a tabletop system
    Greenberg, Joel A.
    Dudley, Colt
    Moody, Ryan
    Richmond, Turner
    Espenhahn, Eric
    Pike, Daniel
    Kida, Sakurako
    Kapadia, Anuj J.
    Coccarelli, David
    ANOMALY DETECTION AND IMAGING WITH X-RAYS, ADIX IX, 2024, 13043
  • [7] High-resolution imaging of depth filter structures using X-ray computed tomography
    Johnson, T. F.
    Iacoviello, F.
    Welsh, J. H.
    Shearing, P. R.
    Bracewell, D. G.
    JOURNAL OF MATERIALS SCIENCE, 2021, 56 (27) : 15313 - 15326
  • [8] Development of a digital X-ray imaging module for portable high-resolution imaging applications
    Cho, H
    Jeong, M
    Kim, S
    Lee, B
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2005, 46 (05) : 1096 - 1101
  • [9] Light Management of Metal Halide Scintillators for High-Resolution X-Ray Imaging
    Xu, Xiuwen
    Xie, Yue-Min
    Shi, Huaiyao
    Wang, Yongquan
    Zhu, Xianjun
    Li, Bing-Xiang
    Liu, Shujuan
    Chen, Bing
    Zhao, Qiang
    ADVANCED MATERIALS, 2024, 36 (03)
  • [10] High-resolution x-ray luminescence computed tomography
    Lun, Michael C.
    Li, Changqing
    MEDICAL IMAGING 2020: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11317