Evaluation of a newly designed flow diverter for the treatment of intracranial aneurysms in an elastase-induced aneurysm model, in New Zealand white rabbits

被引:0
作者
Simgen, Andreas [1 ]
Ley, Desiree [1 ]
Roth, Christian [2 ]
Yilmaz, Umut [1 ]
Koerner, Heiko [1 ]
Muehl-Benninghaus, Ruben [1 ]
Kim, Yoo-Jin [3 ]
Scheller, Bruno [4 ]
Reith, Wolfgang [1 ]
机构
[1] Saarland Univ Hosp, Dept Neuroradiol, D-66424 Homburg, Germany
[2] Clin Bremen Mitte, Dept Neuroradiol, Bremen, Germany
[3] Saarland Univ Hosp, Dept Pathol, Homburg, Saarland, Germany
[4] Saarland Univ Hosp, Dept Cardiol, Homburg, Saarland, Germany
关键词
Intracranial aneurysms; Animal model; Flow diverter; Stening; PIPELINE EMBOLIZATION DEVICE; SACCULAR ANEURYSMS; DISRUPTING DEVICE; FOLLOW-UP; IN-VIVO; STENT; TRIAL; RECONSTRUCTION; IMPLANTATION; MULTICENTER;
D O I
10.1007/s00234-013-1296-9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
In this study, we analyzed angiographic and histologic aneurysm occlusion of a newly designed flow-diverting device. Visibility and flexibility, as well as occlusions of side branches and neointimal proliferation were also evaluated. Aneurysms were induced in 18 New Zealand white rabbits and treated with a braided, "closed-loop-designed" device of nitinol. Additional devices were implanted in the abdominal aorta to cover the origin of branch arteries. Angiographic follow-ups were performed immediately after placement of the device, after 3 months (n = 9) and 6 months (n = 9). The status of aneurysm occlusion (using a five-point scale) and the patency of branch arteries were assessed. Aneurysm occlusion rates were noted as grade 0 in 2 (11 %), grade I in 1 (6 %), grade II in 1 (6 %), grade III in 9 (50 %), and grade IV in 5 (28 %) of 18 aneurysms, respectively, indicating a complete or near-complete occlusion of 78 % under double antiplatelet therapy. Aneurysm occlusion was significantly higher at 6 months follow-up (P = 0.025). Radiopaque markers provided excellent visibility. Limited device flexibility led to incomplete aneurysm neck coverage and grade 0 occlusion rates in two cases. Distal device occlusions were found in three cases, most likely due to an extremely undersized vessel diameter in the subclavian artery. No case of branch artery occlusion was seen. Intimal proliferation and diameter stenosis were moderate. The tested flow diverter achieved near-complete and complete aneurysm occlusion under double antiplatelet therapy of elastase-induced aneurysms in 78 %, while preserving branch arteries.
引用
收藏
页码:129 / 137
页数:9
相关论文
共 27 条
[1]   Remodeling of in-stent neointima, which became thinner and transparent over 3 years - Serial angiographic and angioscopic follow-up [J].
Asakura, M ;
Ueda, Y ;
Nanto, S ;
Hirayama, A ;
Adachi, T ;
Kitakaze, M ;
Hori, M ;
Kodama, K .
CIRCULATION, 1998, 97 (20) :2003-2006
[2]   An in vitro study of silk stent morphology [J].
Aurboonyawat, Thaweesak ;
Blanc, Raphael ;
Schmidt, Paul ;
Piotin, Michel ;
Spelle, Laurent ;
Nakib, Amir ;
Moret, Jacques .
NEURORADIOLOGY, 2011, 53 (09) :659-667
[3]   Pipeline for Uncoilable or Failed Aneurysms: Results from a Multicenter Clinical Trial [J].
Becske, Tibor ;
Kallmes, David F. ;
Saatci, Isil ;
McDougall, Cameron G. ;
Szikora, Istvn ;
Lanzino, Giuseppe ;
Moran, Christopher J. ;
Woo, Henry H. ;
Lopes, Demetrius K. ;
Berez, Aaron L. ;
Cher, Daniel J. ;
Siddiqui, Adnan H. ;
Levy, Elad I. ;
Albuquerque, Felipe C. ;
Fiorella, David J. ;
Berentei, Zsolt ;
Marosfoi, Miklos ;
Cekirge, Saruhan H. ;
Nelson, Peter K. .
RADIOLOGY, 2013, 267 (03) :858-868
[4]   Flow-Diverter Silk Stent for the Treatment of Intracranial Aneurysms: 1-year Follow-Up in a Multicenter Study [J].
Berge, J. ;
Biondi, A. ;
Machi, P. ;
Brunel, H. ;
Pierot, L. ;
Gabrillargues, J. ;
Kadziolka, K. ;
Barreau, X. ;
Dousset, V. ;
Bonafe, A. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (06) :1150-1155
[5]   Aneurysm Rupture Following Treatment with Flow-Diverting Stents: Computational Hemodynamics Analysis of Treatment [J].
Cebral, J. R. ;
Mut, F. ;
Raschi, M. ;
Scrivano, E. ;
Ceratto, R. ;
Lylyk, P. ;
Putman, C. M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (01) :27-33
[6]   Endovascular creation of an in vivo bifurcation aneurysm model in rabbits [J].
Cloft, HJ ;
Altes, TA ;
Marx, WF ;
Raible, RJ ;
Hudson, SB ;
Helm, GA ;
Mandell, JW ;
Jensen, ME ;
Dion, JE ;
Kallmes, DF .
RADIOLOGY, 1999, 213 (01) :223-228
[7]   Inhibition of neointimal proliferation after bare metal stent implantation with low-pressure drug delivery using a paclitaxel-coated balloon in porcine coronary arteries [J].
Cremers, Bodo ;
Kelsch, Bettina ;
Clever, Yvonne P. ;
Hattangadi, Neil ;
Mahnkopf, Dirk ;
Speck, Ulrich ;
Taupitz, Matthias ;
Scheller, Bruno .
CLINICAL RESEARCH IN CARDIOLOGY, 2012, 101 (05) :385-391
[8]   Bone formation in elastase-induced rabbit aneurysms embolized with platinum coils: Report of 2 cases [J].
Dai, D. ;
Ding, Y. H. ;
Kadirvel, R. ;
Lewis, D. A. ;
Cloft, H. J. ;
Kallmes, D. F. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2007, 28 (06) :1176-1178
[9]   Patency of Branches after Coverage with Multiple Telescoping Flow-Diverter Devices: An In Vivo Study in Rabbits [J].
Dai, D. ;
Ding, Y. H. ;
Kadirvel, R. ;
Rad, A. E. ;
Lewis, D. A. ;
Kallmes, D. F. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (01) :171-174
[10]   Definitive reconstruction of circumferential fusiform intracranial aneurysms with the pipeline embolization device [J].
Fiorella, David ;
Woo, Henry H. ;
Albuquerque, Felipe C. ;
Nelson, Peter K. .
NEUROSURGERY, 2008, 62 (05) :1115-1120