Verification of radiosurgery target point alignment with an electronic portal imaging device (EPID)

被引:34
作者
Dong, L [1 ]
Shiu, A [1 ]
Tung, S [1 ]
Boyer, A [1 ]
机构
[1] STANFORD UNIV HOSP,DEPT RADIAT ONCOL,DIV RADIAT PHYS,STANFORD,CA 94305
关键词
stereotactic radiosurgery; treatment verification; target simulator; quality assurance; portal imaging;
D O I
10.1118/1.598070
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A procedure has been developed using an electronic portal imaging device (EPID) to verify that the center of a patient's lesion is aligned with the center of a treatment cone prior to treatment in a linac-based stereotactic radiosurgery procedure. The coordinates of the lesion center are set on the Brown-Reberts-Wells phantom base using a target simulator. A 3 mm tungsten ball, mounted on the target simulator, is used as the reference point for the planned isocenter. The target simulator is then attached to an adapter mounted on the linac couch, and an EPID image of the simulated target is acquired. The center of the circular-shaped radiation field is calculated from the centroid of the segmented EPID image, and the center of the tungsten ball is identified by an automated computer search algorithm. A summation filter is used to find the position of the lowest radiation intensity coincident with the center of the ball. The alignment error is defined as the difference between the center of the radiation field and the center of the ball. The accuracy of this method was tested and found to be within 0.2 mm. The advantage of the EPID-based procedure is that it can give quantitative offset values quickly for immediate readjustment. We have found that the method is also a convenient tool for testing room laser alignment and the accuracy of the treatment cones. (C) 1997 American Association of Physicists in Medicine.
引用
收藏
页码:263 / 267
页数:5
相关论文
共 13 条
[1]   FINE-TUNING OF LINEAR-ACCELERATOR ACCESSORIES FOR STEREOTAXIC RADIOTHERAPY [J].
ENGLER, MJ ;
CURRAN, BH ;
TSAI, JS ;
STERNICK, ES ;
SELLES, WD ;
WAZER, DE ;
MASON, WP ;
SAILOR, T ;
MACKIE, TR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (04) :1001-1008
[2]   PRECISION AND ACCURACY OF STEREOTAXIC CONVERGENT-BEAM IRRADIATIONS FROM A LINEAR-ACCELERATOR [J].
HARTMANN, GH ;
BAUERKIRPES, B ;
SERAGO, CF ;
LORENZ, WJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (02) :481-492
[3]   PRELIMINARY EXPERIENCE WITH BROWN-ROBERTS-WELLS (BRW) COMPUTERIZED-TOMOGRAPHY STEREOTAXIC GUIDANCE-SYSTEM [J].
HEILBRUN, MP ;
ROBERTS, TS ;
APUZZO, MLJ ;
WELLS, TH ;
SABSHIN, JK .
JOURNAL OF NEUROSURGERY, 1983, 59 (02) :217-222
[4]  
HEILBRUN MP, 1983, INSTRUCTION MANUAL B
[5]   MINIMIZATION OF TARGET POSITIONING ERROR IN ACCELERATOR-BASED RADIOSURGERY [J].
LOW, DA ;
LI, ZF ;
DRZYMALA, RE .
MEDICAL PHYSICS, 1995, 22 (04) :443-448
[6]   A SYSTEM FOR STEREOTACTIC RADIOSURGERY WITH A LINEAR-ACCELERATOR [J].
LUTZ, W ;
WINSTON, KR ;
MALEKI, N .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (02) :373-381
[7]   STEREOTAXIC TARGET POINT VERIFICATION OF AN X-RAY AND CT LOCALIZER [J].
SERAGO, CF ;
LEWIN, AA ;
HOUDEK, PV ;
GONZALEZARIAS, S ;
HARTMANN, GH ;
ABITBOL, AA ;
SCHWADE, JG .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (03) :517-523
[8]   RADIOSURGERY TARGET POINT ALIGNMENT ERRORS DETECTED WITH PORTAL FILM VERIFICATION [J].
SERAGO, CF ;
LEWIN, AA ;
HOUDEK, PV ;
GONZALEZARIAS, S ;
SCHWADE, JG ;
ABITOL, A ;
MARCIALVEGA, V .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 24 (04) :777-780
[9]  
SHIU A S, 1991, Medical Physics (Woodbury), V18, P630
[10]   STEREOTAXIC LOCALIZATION OF INTRACRANIAL TARGETS [J].
SIDDON, RL ;
BARTH, NH .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (08) :1241-1246