Multiple-helix cobalt(II)-based metal-organic nanotubes on stainless steel fibers for solid-phase microextraction of chlorophenol and nitrophenols from water samples

被引:36
作者
Li, Qiu-Lin [1 ]
Huang, Fang [2 ]
Wang, Xiao-Li [1 ]
Wang, Xia [1 ]
Zhao, Ru-Song [1 ]
机构
[1] Shandong Acad Sci, Key Lab Appl Technol Sophisticated Analyt Instrum, Anal & Test Ctr, Jinan, Peoples R China
[2] Wuhan Univ Technol, Sch Resources & Environm Engn, Wuhan 430070, Peoples R China
基金
中国国家自然科学基金;
关键词
Phenols; SPME; Environmental analysis; Gas chromatography-tandem mass spectrometry; PERFORMANCE LIQUID-CHROMATOGRAPHY; MULTIWALLED CARBON NANOTUBES; PHENOLIC-COMPOUNDS; ENVIRONMENTAL WATER; GAS-CHROMATOGRAPHY; POLYCHLORINATED-BIPHENYLS; MASS-SPECTROMETRY; AQUEOUS SAMPLES; EXTRACTION; FRAMEWORK;
D O I
10.1007/s00604-017-2167-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The high performance solid-phase microextraction (SPME) of polar phenols from aqueous matrices is a challenge due to the strong interaction between water molecules and polar phenols. The authors describe the fabrication of stainless steel fibers coated with multiple helix 3D metal-organic nanotubes via physical adhesion, and their application to the SPME of 2-chlorophenol, 2-nitrophenol, 2,4-dichlorophenol, 4-chloro-3-methylphenol and 2,4,6-trichlorophenol from water samples. GC/MS was used for sample quantification and detection. Box-Behnken design was adopted to optimize the experimental conditions through response surface methodology. The fibers display good thermal stability (similar to 400 A degrees C), high enrichment factors (418-1874), excellent repeatability (4.31%-8.37%), wide linear range (0.5-1000 ng.L-1) and low limits of detection (0.07-0.18 ngai.L-1) for the phenols. This method was successfully applied to the analysis of phenols in environmental water samples.
引用
收藏
页码:1817 / 1825
页数:9
相关论文
共 34 条
[31]   Molecular dynamics simulation of the hydration structure and hydrogen bonding behavior of phenol in aqueous solution [J].
Zhang, Ning ;
Ruan, Xuehua ;
Song, Yuechun ;
Liu, Zhao ;
He, Gaohong .
JOURNAL OF MOLECULAR LIQUIDS, 2016, 221 :942-948
[32]   Simultaneous analysis of eight phenolic environmental estrogens in blood using dispersive micro-solid-phase extraction combined with ultra fast liquid chromatography-tandem mass spectrometry [J].
Zhao, Yong-Gang ;
Chen, Xiao-Hong ;
Pan, Sheng-Dong ;
Zhu, Hao ;
Shen, Hao-Yu ;
Jin, Mi-Cong .
TALANTA, 2013, 115 :787-797
[33]   Polydimethylsiloxane/covalent triazine frameworks coated stir bar sorptive extraction coupled with high performance liquid chromatography-ultraviolet detection for the determination of phenols in environmental water samples [J].
Zhong, Cheng ;
He, Man ;
Liao, Huaping ;
Chen, Beibei ;
Wang, Cheng ;
Hu, Bin .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1441 :8-15
[34]   Preparation and characterization of vinyl-functionalized mesoporous organosilica-coated solid-phase microextraction fiber [J].
Zhu, Fang ;
Liang, Yongjin ;
Xia, Liaoyuan ;
Rong, Minzhi ;
Su, Chengyong ;
Lai, Rong ;
Li, Ruiying ;
Ouyang, Gangfeng .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1247 :42-48