Changes in the ADC of diffusion-weighted MRI with the oscillating gradient spin-echo (OGSE) sequence due to differences in substrate viscosities

被引:14
作者
Maekawa, Tomoko [1 ,2 ,3 ]
Hori, Masaaki [1 ]
Murata, Katsutoshi [4 ]
Feiweier, Thorsten [5 ]
Fukunaga, Issei [1 ]
Andica, Christina [1 ]
Hagiwara, Akifumi [1 ,2 ,3 ]
Kamagata, Koji [1 ]
Koshino, Saori [1 ,2 ,3 ]
Abe, Osamu [2 ,3 ]
Aoki, Shigeki [1 ]
机构
[1] Juntendo Univ, Sch Med, Dept Radiol, Bunkyo Ku, 2-1-1 Hongo, Tokyo 1138421, Japan
[2] Univ Tokyo, Grad Sch Med, Dept Radiol, Bunkyo Ku, 7-3-1 Hongo, Tokyo 1138655, Japan
[3] Univ Tokyo, Fac Med, Bunkyo Ku, 7-3-1 Hongo, Tokyo 1138655, Japan
[4] Siemens Healthcare Japan KK, Shinagawa Ku, Gate City Osaki West Tower,11-1 Osaka 1 Chome, Tokyo 1418644, Japan
[5] Siemens Healthcare GmbH, Henkestr 127, D-91052 Erlangen, Germany
关键词
Oscillating gradient spin-echo; Alkane; Isotropic diffusion; Phantom; ADC; WATER DIFFUSION; PROTON-DENSITY; SYNTHETIC-MRI; IN-VIVO; BRAIN; SPECTROSCOPY; STROKE; REPRODUCIBILITY; QUANTIFICATION; ISCHEMIA;
D O I
10.1007/s11604-018-0737-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Compared with the conventional pulsed gradient spin-echo (PGSE) sequence, diffusion-weighted imaging (DWI) with the oscillating gradient spin-echo (OGSE) sequence can shorten the diffusion time by changing the frequency. The purpose was to investigate whether n-alkanes are suitable as isotropic phantoms for estimating the diffusion coefficient with the OGSE sequence. We investigated changes in the apparent diffusion coefficient (ADC) due to differences in the viscosities of nine n-alkane phantoms with different numbers of carbon atoms from C8H18 to C16H34 using OGSE and PGSE sequences at 21 A degrees C. Effective diffusion times of 4.3, 5.1, 6.5, 9.3, 20, 40, and 60 ms were used. The T-2 relaxation times of each n-alkane phantom were measured using quantitative synthetic magnetic resonance imaging (MRI). Circular regions of interest were placed manually within the alkane phantoms on ADC and T-2 maps. In each alkane phantom, changes in mean ADC values were almost constant with changes in diffusion times. Viscosities and ADC values showed inverse proportionality, as expected theoretically. The ADC values of alkanes do not depend on diffusion times. The n-alkanes can be useful phantoms for assessing the accuracy of clinical protocols of DWI with the OGSE sequence.
引用
收藏
页码:415 / 420
页数:6
相关论文
共 27 条
  • [1] Probing mouse brain microstructure using oscillating gradient diffusion MRI
    Aggarwal, Manisha
    Jones, Melina V.
    Calabresi, Peter A.
    Mori, Susumu
    Zhang, Jiangyang
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (01) : 98 - 109
  • [2] Spatial Restriction within Intracranial Epidermoid Cysts Observed Using Short Diffusion-time Diffusion-weighted Imaging
    Andica, Christina
    Hori, Masaaki
    Kamiya, Kouhei
    Koshino, Saori
    Hagiwara, Akifumi
    Kamagata, Koji
    Fukunaga, Issei
    Hamasaki, Nozomi
    Suzuki, Michimasa
    Feiweier, Thorsten
    Murata, Katsutoshi
    Arakawa, Atsushi
    Kondo, Akihide
    Akiyama, Osamu
    Aoki, Shigeki
    [J]. MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2018, 17 (03) : 269 - 272
  • [3] [Anonymous], 2017, CRC HDB CHEM PHYS
  • [4] Reduction of Diffusion-Weighted Imaging Contrast of Acute Ischemic Stroke at Short Diffusion Times
    Baron, Corey Allan
    Kate, Mahesh
    Gioia, Laura
    Butcher, Kenneth
    Emery, Derek
    Budde, Matthew
    Beaulieu, Christian
    [J]. STROKE, 2015, 46 (08) : 2136 - 2141
  • [5] MR diffusion imaging in stroke: Review and controversies
    Beauchamp, NJ
    Ulug, AM
    Passe, TJ
    van Zijl, PCM
    [J]. RADIOGRAPHICS, 1998, 18 (05) : 1269 - 1283
  • [6] WATER DIFFUSION IN THE GIANT-AXON OF THE SQUID - IMPLICATIONS FOR DIFFUSION-WEIGHTED MRI OF THE NERVOUS-SYSTEM
    BEAULIEU, C
    ALLEN, PS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (05) : 579 - 583
  • [7] An in vitro evaluation of the effects of local magnetic-susceptibility-induced gradients on anisotropic water diffusion in nerve
    Beaulieu, C
    Allen, PS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (01) : 39 - 44
  • [8] Oscillating gradient measurements of water diffusion in normal and globally ischemic rat brain
    Does, MD
    Parsons, EC
    Gore, JC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (02) : 206 - 215
  • [9] SyMRI of the Brain Rapid Quantification of Relaxation Rates and Proton Density, With Synthetic MRI, Automatic Brain Segmentation, and Myelin Measurement
    Hagiwara, Akifumi
    Warntjes, Marcel
    Hori, Masaaki
    Andica, Christina
    Nakazawa, Misaki
    Kumamaru, Kanako Kunishima
    Abe, Osamu
    Aoki, Shigeki
    [J]. INVESTIGATIVE RADIOLOGY, 2017, 52 (10) : 647 - 657
  • [10] Dural Enhancement in a Patient with Sturge-Weber Syndrome Revealed by Double Inversion Recovery Contrast Using Synthetic MRI
    Hagiwara, Akifumi
    Nakazawa, Misaki
    Andica, Christina
    Tsuruta, Kouhei
    Takano, Nao
    Hori, Masaaki
    Suzuki, Hiroharu
    Sugano, Hidenori
    Arai, Hajime
    Aoki, Shigeki