Comparison of microcomputed tomography, cone beam tomography, stereomicroscopy, and scanning electron microscopy techniques for detection of microcracks on root dentin and effect of different apical sizes on microcrack formation

被引:10
作者
Capar, Ismail D. [1 ]
Gok, Tuba [2 ]
Uysal, Banu [3 ]
Keles, Ali [4 ]
机构
[1] Periodent Dent Clin, Istanbul, Turkey
[2] Firat Univ, Fac Dent, Dept Endodont, Elazig, Turkey
[3] Pros Esthet Oral & Dent Hlth Clin, Izmir, Turkey
[4] Ondokuz Mayis Univ, Fac Dent, Dept Endodont, Samsun, Turkey
关键词
cone beam computed tomography; dentinal microcrack; micro-computed tomography; scanning electron microscopy; stereomicroscopy; SELF-ADJUSTING FILE; ENDODONTICALLY TREATED TEETH; COMPUTED-TOMOGRAPHY; CANAL PREPARATION; PROTAPER UNIVERSAL; INSTRUMENTS; FRACTURES; DEFECTS; SYSTEMS; RETREATMENT;
D O I
10.1002/jemt.23341
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
The aim of the study was to compare different imaging methods in the diagnosis of microcracks on root dentin and to evaluate the frequency of dentinal microcracks observed after root canal preparation using the ProTaper Universal (PTU) system of different sizes. A total of 30 mandibular molars' mesial roots were scanned with microcomputed tomography (micro-CT) and cone beam computed tomography (CBCT) imaging methods before instrumentation. Root canal instrumentation was performed up to PTU F2 and F4 files. After instrumentation stages, the roots were scanned again with micro-CT and then with CBCT in same parameters. All roots were sectioned horizontally at 2, 4, 6, 8, and 10 mm from the apices of the specimens. The sections were imaged under a stereomicroscope. Finally, imaging of the sections was done by scanning electron microscopy (SEM). Statistical data analysis of instrumentation steps was performed using Friedman and Wilcoxon tests, and the data of imaging methods were analyzed using Kruskal-Wallis and Mann-Whitney U tests (p = .05). Instrumentation with the PTU system up to F2 and F4 files significantly increased the number of microcracks compared with preoperative samples according to micro-CT imaging (p < .05). For detecting microcracks on the root dentin, there were no statistically significant differences between micro-CT (43.9%) and stereomicroscopy (45.8%) (p < .05). SEM showed significantly higher percentage of microcracks (88.3%) (p > .05). No microcrack was observed using the CBCT method. There were no statistically differences between micro-CT and stereomicroscopy. SEM showed more dentinal microcracks while no microcrack was observed with CBCT.
引用
收藏
页码:1748 / 1755
页数:8
相关论文
共 39 条
  • [1] Effect of ProTaper Universal, Endoflare, Revo-S, HyFlex Coronal Flaring Instruments, and Gates Glidden Drills on Crack Formation
    Arslan, Hakan
    Karatas, Ertugrul
    Capar, Ismail Davut
    Ozsu, Damla
    Doganay, Ezgi
    [J]. JOURNAL OF ENDODONTICS, 2014, 40 (10) : 1681 - 1683
  • [2] Effect of reciprocating file motion on microcrack formation in root canals: an SEM study
    Ashwinkumar, V.
    Krithikadatta, J.
    Surendran, S.
    Velmurugan, N.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (07) : 622 - 627
  • [3] Aydemir Seda, 2013, Eur J Dent, V7, P186, DOI 10.4103/1305-7456.110168
  • [4] Vertical Root Fractures and Dentin Defects: Effects of Root Canal Preparation, Filling, and Mechanical Cycling
    Barreto, Mirela Sangoi
    Moraes, Rafael do Amaral
    da Rosa, Ricardo Abreu
    Cunha Moreira, Carlos Heitor
    Reis So, Marcus Vinicius
    Souza Bier, Carlos Alexandre
    [J]. JOURNAL OF ENDODONTICS, 2012, 38 (08) : 1135 - 1139
  • [5] Effect of ProTaper Gold, Self-Adjusting File, and XP-endo Shaper Instruments on Dentinal Microcrack Formation: A Micro-computed Tomographic Study
    Bayram, H. Melike
    Bayram, Emre
    Ocak, Mert
    Uygun, Ahmet Demirhan
    Celik, Hakan Hamdi
    [J]. JOURNAL OF ENDODONTICS, 2017, 43 (07) : 1166 - 1169
  • [6] Effects of ProTaper Universal, ProTaper Next, and HyFlex Instruments on Crack Formation in Dentin
    Capar, Ismail Davut
    Arslan, Hakan
    Akcay, Merve
    Uysal, Banu
    [J]. JOURNAL OF ENDODONTICS, 2014, 40 (09) : 1482 - 1484
  • [7] Comparison of ProTaper, RaCe and Safesider instruments in the induction of dentinal microcracks: a micro-CT study
    Ceyhanli, K. T.
    Erdilek, N.
    Tatar, I.
    Celik, D.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2016, 49 (07) : 684 - 689
  • [8] Evaluation of Microcrack Formation in Root Canals After Instrumentation With different NiTi Rotary File Systems: A Scanning Electron Microscopy Study
    Cicek, Ersan
    Kocak, Mustafa Murat
    Saglam, Baran Can
    Kocak, Sibel
    [J]. SCANNING, 2015, 37 (01) : 49 - 53
  • [9] Detection of vertical root fractures by conventional radiographic examination and cone beam computed tomography - an in vitro analysis
    da Silveira, Priscila Fernanda
    Vizzotto, Mariana Boessio
    Liedke, Gabriela Salatino
    Dias da Silveira, Heraldo Luis
    Montagner, Francisco
    Dias da Silveira, Heloisa Emilia
    [J]. DENTAL TRAUMATOLOGY, 2013, 29 (01) : 41 - 46
  • [10] Detection of Apical Root Cracks Using Spectral Domain and Swept-source Optical Coherence Tomography
    de Oliveira, Bruna Paloma
    Camara, Andrea Cruz
    Duarte, Daniel Amancio
    Leonidas Gomes, Anderson Stevens
    Heck, Richard John
    Dantas Antonino, Antonio Celso
    Aguiar, Carlos Menezes
    [J]. JOURNAL OF ENDODONTICS, 2017, 43 (07) : 1148 - 1151