Transcranial Doppler and magnetic resonance angiography assessment of intracranial stenosis: An analysis of screening modalities

被引:6
|
作者
Mowla, Ashkan [1 ]
Shakibajahromi, Banafsheh [5 ]
Kabir, Rasadul [2 ]
Garami, Zsolt [3 ,4 ]
Volpi, John J. [2 ]
机构
[1] Univ Southern Calif, Keck Sch Med, Dept Neurol Surg, Div Endovasc Neurosurg, 1200 North State St,Suite 3300, Los Angeles, CA 90033 USA
[2] Houston Methodist Hosp, Dept Neurol, Weill Cornell Med Coll, Houston Methodist Neurol Inst, Houston, TX 77030 USA
[3] Houston Methodist Hosp, Res Inst, Weill Cornell Med Coll, Inst Acad Med, Houston, TX 77030 USA
[4] Houston Methodist Hosp, Weill Cornell Med Coll, Vasc Ultrasound Lab, Houston, TX 77030 USA
[5] Shiraz Univ Med Sci, Clin Neurol Res Ctr, Shiraz, Iran
关键词
Intracranial stenosis; magnetic resonance angiography; screening; stroke; transcranial Doppler sonography; OCCLUSIVE DISEASE; ACCURACY; STROKE; TCD;
D O I
10.4103/bc.bc_21_20
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Time-of-flight (TOF) magnetic resonance angiography (MRA) of the head and transcranial Doppler (TCD) are used to diagnose intracranial stenosis, an important cause of ischemic stroke. We aimed to compare TCD findings with TOF-MRA results in a population of patients with symptoms of cerebrovascular disease in whom both tests were done within a short intervening period of each other. METHODS: This is a retrospective, single-center study. Among adult patients referred for symptoms of cerebrovascular disease in both outpatient and inpatient settings, those who received a TCD with adequate insonation of all intracranial arteries and underwent MRA within 3 months intervals of TCD were included in this study. We evaluated the agreement between the results of these two modalities, and also assessed sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of TCD through receiver-operating characteristic (ROC) curve analysis, while MRA considered as a comparator. RESULTS: Among eighty included patients, 720 arteries were examined. An overall significant agreement of 96.5% was observed between TCD and MRA (Kappa = 0.377, P < 0.001). Compared to MRA, TCD had sensitivity of 42.1%, specificity of 99.6%, PPV of 72.7%, and NPV of 98.4% (ROC area: 0.708 [0.594-0.822]). TCD is specifically accurate in evaluating middle cerebral artery (MCA) (ROC area = 0.83). CONCLUSIONS: The high NPV of TCD in our study indicates the utility of TCD as a diagnostic test to exclude the presence of intracranial stenosis. This study supports TCD as a convenient, safe, and reproducible imaging modality applicable in the screening of intracranial stenosis, especially to evaluate MCA.
引用
收藏
页码:181 / 184
页数:4
相关论文
共 50 条
  • [41] INTRACRANIAL MAGNETIC-RESONANCE ANGIOGRAPHY
    FURST, G
    HOFER, M
    MODDER, U
    RADIOLOGE, 1994, 34 (08): : 437 - 446
  • [42] Hemodynamic Significance of Internal Carotid or Middle Cerebral Artery Stenosis Detected on Magnetic Resonance Angiography
    Seo, Hyo Jung
    Pagsisihan, Jefferson R.
    Paeng, Jin Chul
    Choi, Seung Hong
    Cheon, Gi Jeong
    Chung, June-Key
    Lee, Dong Soo
    Kang, Keon Wook
    YONSEI MEDICAL JOURNAL, 2015, 56 (06) : 1686 - 1693
  • [43] Asymptomatic middle cerebral artery stenosis diagnosed by magnetic resonance angiography
    Zaidat, OO
    Zahuranec, DB
    Ubogu, EE
    Fernandes, JA
    Suárez, JI
    Sunshine, JL
    Tarr, RW
    Mirarchi, S
    Nour, SG
    Selman, WR
    Landis, DMD
    NEURORADIOLOGY, 2004, 46 (01) : 49 - 53
  • [44] Magnetic resonance angiography and transcranial Doppler ultrasound findings in patients with a clinical diagnosis of vertebrobasilar insufficiency
    Lima Neto, Arlindo Cardoso
    Bor-Seng-Shu, Edson
    Oliveira, Marcelo de Lima
    Macedo-Soares, Alberto
    Topciu, Flavia Renata
    Moreira Bitter, Roseli Saraiva
    CLINICS, 2020, 75
  • [45] Overestimation of the degree of stenosis in the intracranial internal carotid artery determined by magnetic resonance angiography compared to conventional arteriography
    Durán-Ferreras, E
    Schoeck, AP
    Barest, GD
    Viereck, JC
    Babikian, VL
    Kase, CS
    REVISTA DE NEUROLOGIA, 2003, 37 (08) : 730 - 732
  • [46] Color-coded duplex sonography vs. 3.0 Tesla magnetic resonance angiography for detection of intracranial stenosis of the internal carotid artery: A prospective cohort study
    Xiao, Lu
    Chu, Wen
    Wang, Hua
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2020, 19 (01) : 473 - 480
  • [47] The Role of Transcranial Doppler Embolic Monitoring in the Management of Intracranial Arterial Stenosis
    Sebastian, Joseph
    Derksen, Carol
    Khan, Khurshid
    Saqqur, Maher
    JOURNAL OF NEUROIMAGING, 2011, 21 (02) : e166 - e168
  • [48] Multi-assessment of critical steno-occlusive middle cerebral arteries: transcranial Doppler combined with magnetic resonance angiography
    Mo, Xiuyun
    Ma, Zelan
    Lin, Hao
    Ou, Aihua
    He, Xumin
    Liu, Guoqing
    Zhou, Ting
    Zhong, Jingxin
    HELIYON, 2022, 8 (10)
  • [49] Comparison of transcranial color-coded sonography and magnetic resonance angiography in acute stroke
    Kenton, AR
    Martin, PJ
    Abbott, RJ
    Moody, AR
    STROKE, 1997, 28 (08) : 1601 - 1606
  • [50] Transcranial Doppler sonography for detecting stenosis or occlusion of intracranial arteries in people with acute ischaemic stroke
    Mattioni, Alessia
    Cenciarelli, Silvia
    Eusebi, Paolo
    Brazzelli, Miriam
    Mazzoli, Tatiana
    Del Sette, Massimo
    Gandolfo, Carlo
    Marinoni, Marinella
    Finocchi, Cinzia
    Saia, Valentina
    Ricci, Stefano
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2020, (02):