Intensification of mass transfer in a pulsed bubble column

被引:21
作者
Budzynski, P. [1 ]
Gwiazda, A. [1 ]
Dziubinski, M. [1 ]
机构
[1] Lodz Univ Technol, Fac Proc Environm Engn, Wolczanska 213, PL-90924 Lodz, Poland
关键词
LIQUID; PERFORMANCE; RESONANCE; MOTION;
D O I
10.1016/j.cep.2016.12.004
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The application of liquid pulsations to a classic bubble column substantially changes the hydrodynamics of bubble flow and the process of mass transfer. The paper presents a wide range of experimental results concerning the intensification of mass transfer in a pulsed bubble column of square cross section with side D = 0.135 m and slenderness ratio H-p/D ranging from 3 to 14.5. Experimental measurements were carried out at a frequency ranging from 1 to 70 Hz and the amplitude of a disk vibration exciter from 0.25 to 2 mm. The effect of liquid pulsation and volumetric gas flow rate on gas hold-up epsilon(G), mass transfer coefficient k(L)a and free liquid surface deflection Y-i was investigated. It was shown that the application of pulsations to a bubble column caused a significant increase of gas hold-up and mass transfer coefficients. Based on the experimental results correlation equations for gas hold-up and mass transfer coefficient in a bubble column (with and without pulsations) were proposed and confirmed experimentally with an accuracy of +/- 15% and +/- 25%, respectively. A simple method in the form of a diagram has been proposed to determine optimal operating conditions of a pulsed bubble column. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:18 / 30
页数:13
相关论文
共 30 条
  • [1] BAIRD MHI, 1963, CHEM ENG SCI, V18, P685
  • [2] Bretsznajder S., 1964, International Chemical Engineering, V4, P61
  • [3] CYCLIC MIGRATION OF BUBBLES IN VERTICALLY VIBRATING LIQUID COLUMNS
    BUCHANAN, RH
    JAMESON, G
    OEDJOE, D
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1962, 1 (02): : 82 - &
  • [4] Budzynski P., 2011, SCI B TU LODZ, V1107, P1
  • [5] Budzynski P, 2007, INZ CHEM PROCESOWA, V28, P995
  • [6] Intensification of bubble column performance by introduction pulsation of liquid
    Budzynski, Pawel
    Dziubinski, Marek
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2014, 78 : 44 - 57
  • [7] Davidson J.F., 1960, T I CHEMENG, V38, P335
  • [8] Membrane engineering in process intensification-An overview
    Drioli, Enrico
    Stankiewicz, Andrzej I.
    Macedonio, Francesca
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2011, 380 (1-2) : 1 - 8
  • [9] Review of Bubble Column Reactors with Vibration
    Elbing, Brian R.
    Still, Adam L.
    Ghajar, Afshin J.
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2016, 55 (02) : 385 - 403
  • [10] Exploiting the Bjerknes force in bubble column reactors
    Ellenberger, J
    van Baten, JM
    Krishna, R
    [J]. CHEMICAL ENGINEERING SCIENCE, 2005, 60 (22) : 5962 - 5970