Quantitative and Qualitative Comparison of Single-Source Dual-Energy Computed Tomography and 120-kVp Computed Tomography for the Assessment of Pancreatic Ductal Adenocarcinoma

被引:48
作者
Bhosale, Priya [1 ]
Le, Ott [1 ]
Balachandran, Aprana [1 ]
Fox, Patricia [2 ]
Paulson, Eric [1 ]
Tamm, Eric [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Diagnost Radiol, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Biostat, Houston, TX 77030 USA
关键词
pancreatic ductal adenocarcinoma; 120; kVp; DECT; CNR and SNR; SPECTRAL MULTIDETECTOR CT; LOW TUBE VOLTAGE; CONTRAST ENHANCEMENT; SECONDARY SIGNS; IMAGE QUALITY; DIAGNOSIS; MDCT;
D O I
10.1097/RCT.0000000000000295
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The aim of this study was to compare contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) between pancreatic-phase dual-energy computed tomography (DECT) and 120-kVp CT for pancreatic ductal adenocarcinoma (PDA). Materials and Methods Seventy-eight patients underwent multiphasic pancreatic imaging protocols for PDA (40, DECT; 38, 120-kVp CT [control]). Using pancreatic phase, CNR and SNR for PDA were obtained for DECT at monochromatic energies 50 through 80 keV, iodine material density images, and 120-kVp images. Using a 5-point scale (1, excellent; 5, markedly limited), images were qualitatively assessed by 2 radiologists in consensus for PDA detection, extension, vascular involvement, and noise. Wilcoxon signed rank and 2-sample tests were used to compare the qualitative measures, CNR and SNR, for DECT and 120-kVp images. Bonferroni correction was applied. Results Iodine material density image had significantly higher CNR and SNR for PDA than any monochromatic energy images (P < 0.0001) and the 120-kVp images. Qualitatively, 70-keV images were rated highest in the categories of tumor extension and vascular invasion and were similar to 120-kVp images. Conclusions Our results indicate that DECT improves PDA lesion conspicuity compared with routine 120-kVp CT, which may allow for better detection of PDA.
引用
收藏
页码:907 / 913
页数:7
相关论文
共 17 条
[1]   Surgically proved visually isoattenuating pancreatic adenocarcinoma undetected in both dynamic CT and MRI. Was blind pancreaticoduodenectomy justified? [J].
Blouhos, Konstantinos ;
Boulas, Konstantinos A. ;
Tselios, Dimitrios G. ;
Katsaouni, Stavroula P. ;
Mauroeidi, Basiliki ;
Hatzigeorgiadis, Anestis .
INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2013, 4 (05) :466-469
[2]   Split-Bolus Spectral Multidetector CT of the Pancreas: Assessment of Radiation Dose and Tumor Conspicuity [J].
Brook, Olga R. ;
Gourtsoyianni, Sofia ;
Brook, Alexander ;
Siewert, Bettina ;
Kent, Tara ;
Raptopoulos, Vassilios .
RADIOLOGY, 2013, 269 (01) :139-148
[3]  
He Yong-Lan, 2013, Chin Med Sci J, V27, P207
[4]   Low tube voltage CT for improved detection of pancreatic cancer: detection threshold for small, simulated lesions [J].
Holm, Jon ;
Loizou, Louiza ;
Albiin, Nils ;
Kartalis, Nikolaos ;
Leidner, Bertil ;
Sundin, Anders .
BMC MEDICAL IMAGING, 2012, 12
[5]   Visually Isoattenuating Pancreatic Adenocarcinoma at Dynamic-Enhanced CT: Frequency, Clinical and Pathologic Characteristics, and Diagnosis at Imaging Examinations [J].
Kim, Jin Hee ;
Park, Seong Ho ;
Yu, Eun Sil ;
Kim, Myung-Hwan ;
Kim, Jihun ;
Byun, Jae Ho ;
Lee, Seung Soo ;
Hwang, Hye Jeon ;
Hwang, Jae-Yeon ;
Lee, Sang Soo ;
Lee, Moon-Gyu .
RADIOLOGY, 2010, 257 (01) :87-96
[6]   Dual-energy perfusion-CT of pancreatic adenocarcinoma [J].
Klauss, M. ;
Stiller, W. ;
Pahn, G. ;
Fritz, F. ;
Kieser, M. ;
Werner, J. ;
Kauczor, H. U. ;
Grenacher, L. .
EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (02) :208-214
[7]   MDCT of the pancreas: Optimizing scanning delay with a bolus-tracking technique for pancreatic, peripancreatic vascular, and hepatic contrast enhancement [J].
Kondo, Hiroshi ;
Kanematsu, Masayuki ;
Goshima, Satoshi ;
Miyoshi, Toshiharu ;
Shiratori, Yoshimune ;
Onozuka, Minoru ;
Moriyama, Noriyuki ;
Bae, Kyongtae T. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (03) :751-756
[8]   Dual energy spectral CT imaging of insulinoma-Value in preoperative diagnosis compared with conventional multi-detector CT [J].
Lin, Xiao Zhu ;
Wu, Zhi Yuan ;
Tao, Ran ;
Guo, Yan ;
Li, Jian Ying ;
Zhang, Jing ;
Chen, Ke Min .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (10) :2487-2494
[9]   Dual-Source Dual-Energy MDCT of Pancreatic Adenocarcinoma: Initial Observations With Data Generated at 80 kVp and at Simulated Weighted-Average 120 kVp [J].
Macari, Michael ;
Spieler, Bradley ;
Kim, Danny ;
Graser, Anno ;
Megibow, Alec Jeffrey ;
Babb, James ;
Chandarana, Hersh .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (01) :W27-W32
[10]   Abdominal CT with low tube voltage: Preliminary observations about radiation dose, contrast enhancement, image quality, and noise [J].
Nakayama, Y ;
Awai, K ;
Funama, Y ;
Hatemura, M ;
Imuta, M ;
Nakaura, T ;
Ryu, D ;
Morishita, S ;
Sultana, S ;
Sato, N ;
Yamashita, Y .
RADIOLOGY, 2005, 237 (03) :945-951