A Fast Minimum Variance Beamforming Method Using Principal Component Analysis

被引:66
作者
Kim, Kyuhong [1 ]
Park, Suhyun [1 ]
Kim, Jungho [1 ]
Park, Sung-Bae [2 ]
Bae, MooHo [2 ]
机构
[1] Samsung Elect, SAIT, Yongin, South Korea
[2] Hallym Univ, Dept Elect Engn, Chunchon, Gangwon Do, South Korea
关键词
Image resolution - Ultrasonic imaging - Beamforming - Imaging systems - Principal component analysis;
D O I
10.1109/TUFFC.2014.2989
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Minimum variance (MV) beamforming has been studied for improving the performance of a diagnostic ultrasound imaging system. However, it is not easy for the MV beamforming to be implemented in a real-time ultrasound imaging system because of the enormous amount of computation time associated with the covariance matrix inversion. In this paper, to address this problem, we propose a new fast MV beamforming method that almost optimally approximates the MV beamforming while reducing the computational complexity greatly through dimensionality reduction using principal component analysis (PCA). The principal components are estimated offline from pre-calculated conventional MV weights. Thus, the proposed method does not directly calculate the MV weights but approximates them by a linear combination of a few selected dominant principal components. The combinational weights are calculated in almost the same way as in MV beamforming, but in the transformed domain of beamformer input signal by the PCA, where the dimension of the transformed covariance matrix is identical to the number of some selected principal component vectors. Both computer simulation and experiment were carried out to verify the effectiveness of the proposed method with echo signals from simulation as well as phantom and in vivo experiments. It is confirmed that our method can reduce the dimension of the covariance matrix down to as low as 2 x 2 while maintaining the good image quality of MV beamforming.
引用
收藏
页码:930 / 945
页数:16
相关论文
共 22 条
[1]   A Low-Complexity Adaptive Beamformer for Ultrasound Imaging Using Structured Covariance Matrix [J].
Asl, Babak Mohammadzadeh ;
Mahloojifar, Ali .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (04) :660-667
[2]   Eigenspace-Based Minimum Variance Beamforming Applied to Medical Ultrasound Imaging [J].
Asl, Babak Mohammadzadeh ;
Mahloojifar, Ali .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (11) :2381-2390
[3]  
Brandwood D. H., 1983, IEE Proceedings H (Microwaves, Optics and Antennas), V130, P11, DOI 10.1049/ip-h-1.1983.0004
[4]   HIGH-RESOLUTION FREQUENCY-WAVENUMBER SPECTRUM ANALYSIS [J].
CAPON, J .
PROCEEDINGS OF THE IEEE, 1969, 57 (08) :1408-&
[5]   Minimum variance beamforming for high frame-rate ultrasound imaging [J].
Holfort, Then Kraglund ;
Gran, Fredrik ;
Jensen, Jorgen Arendt .
2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, :1541-1544
[6]  
Jensen AC, 2012, IEEE T ULTRASON FERR, V59, P1139, DOI [http://dx.doi.org/10.1109/TUFFC.2012.2304, 10.1109/TUFFC.2012.2304]
[7]  
Jensen J. A., 1996, Medical & Biological Engineering & Computing, V34, P351
[8]  
Johnson D. H., 1993, Array Signal Processing: Concepts and Techniques
[9]  
Mann JA, 2002, ULTRASON, P1807
[10]   New routes from minimal approximation error to principal components [J].
Miranda, Abhilash Alexander ;
Le Borgne, Yann-Ael ;
Bontempi, Gianluca .
NEURAL PROCESSING LETTERS, 2008, 27 (03) :197-207