Accelerating ordered-subsets X-ray CT image reconstruction using the linearized augmented Lagrangian framework

被引:1
|
作者
Nien, Hung [1 ]
Fessler, Jeffrey A. [1 ]
机构
[1] Univ Michigan, Dept Elect Engn & Comp Sci, Ann Arbor, MI 48109 USA
来源
MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING | 2014年 / 9033卷
关键词
THRESHOLDING ALGORITHM;
D O I
10.1117/12.2042686
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The augmented Lagrangian (AL) optimization method has drawn more attention recently in imaging applications due to its decomposable structure for composite cost functions and empirical fast convergence rate under weak conditions. However, for problems, e.g., X-ray computed tomography (CT) image reconstruction, where the inner least-squares problem is challenging, the AL method can be slow due to its iterative inner updates. In this paper, using a linearized AL framework, we propose an ordered-subsets (OS) accelerable linearized AL method, OS-LALM, for solving penalized weighted least-squares (PWLS) X-ray CT image reconstruction problems. To further accelerate the proposed algorithm, we also propose a deterministic downward continuation approach for fast convergence without additional parameter tuning. Experimental results show that the proposed algorithm significantly accelerates the "convergence" of X-ray CT image reconstruction with negligible overhead and exhibits excellent gradient error tolerance when using many subsets for OS acceleration.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Quantifying the Importance of the Statistical Assumption in Statistical X-ray CT Image Reconstruction
    Xu, Jingyan
    Tsui, Benjamin M. W.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (01) : 61 - 73
  • [32] An FBP image reconstruction algorithm for x-ray differential phase contrast CT
    Qi, Zhihua
    Chen, Guang-Hong
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [33] CT x-ray tube voltage optimisation and image reconstruction evaluation using visual grading analysis
    Zheng, Xiaoming
    Kim, Ted Myeongsoo
    Davidson, Rob
    Lee, Seongju
    Shin, Cheongil
    Yang, Sook
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [34] Evaluation of accelerated iterative X-ray CT image reconstruction using floating point graphics hardware
    Kole, JS
    Beekman, FJ
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (04): : 875 - 889
  • [35] Evaluation of accelerated iterative X-ray CT image reconstruction using floating point graphics hardware
    Kole, JS
    Viergever, MA
    Beekman, E
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3940 - 3944
  • [36] Diagnostic performance of FDG PET/CT for liver lesions by using SUV difference between Bayesian penalized likelihood (BPL) reconstruction and ordered-subsets expectation maximization (OSEM) reconstruction
    Nogami, Munenobu
    Nakabayashi, Mika
    Yairi, Toshiki
    Hashimoto, Tomohisa
    Maeda, Hiroaki
    Takenaka, Daisuke
    Adachi, Shuji
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [37] X-ray image reconstruction of solder joints by using several algebraic reconstruction techniques
    Shaw, Dein
    Hsu, Po-Yen
    Chen, Shih-Liang
    ADVANCED DESIGN AND MANUFACTURE II, 2010, 419-420 : 281 - 284
  • [38] Forward-Projection Architecture for Fast Iterative Image Reconstruction in X-Ray CT
    Kim, Jung Kuk
    Fessler, Jeffrey A.
    Zhang, Zhengya
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2012, 60 (10) : 5508 - 5518
  • [39] Hybrid of ML-EM and MART algorithms for X-ray CT image reconstruction
    Kasai, R.
    Yamaguchi, Y.
    Kojima, T.
    Yoshinaga, T.
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 125 : 26 - 26
  • [40] Proximal ADMM for Multi-Channel Image Reconstruction in Spectral X-ray CT
    Sawatzky, Alex
    Xu, Qiaofeng
    Schirra, Carsten O.
    Anastasio, Mark A.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (08) : 1657 - 1668