A 63-year-old male patient undergoing cardiac SPECT examination was incidentally found to have a large, photopenic (tracer-deficient) region in the right lobe of the liver. Follow-up abdominal CT scan demonstrated a corresponding large (7.8 cm x 6.9 cm), hypodense hepatic lesion. Subsequent CT-guided biopsy revealed metastatic carcinoma of uncertain primary source.
引用
收藏
页码:821 / 822
页数:2
相关论文
共 9 条
[1]  
BERMAN DS, 2001, CARDIAC SPECT IMAGIN, P179
[2]   Incidental detection of hepatocellular carcinoma by SPECT myocardial perfusion imaging [J].
Bhambhvani, Pradeep ;
Dubovsky, Eva ;
Heo, Jaekyeong ;
Iskandrian, Ami .
JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (06) :1116-1117
[3]  
Chatziioannou SN, 1999, TEX HEART I J, V26, P229
[4]   Hepatic cysts detected on myocardial perfusion scintigraphy [J].
Duarte, PS ;
Zhuang, HM ;
Blasbalg, R ;
Aldighieri, F ;
Martins, LRF ;
Alonso, G .
CLINICAL NUCLEAR MEDICINE, 2001, 26 (05) :468-469
[5]   Technetium-99m methoxyisobutylisonitrile single-photon emission tomography in hepatocellular carcinoma [J].
Fukushima, K ;
Kono, M ;
Ishii, K ;
Sakai, E ;
Hirota, S ;
Yuri, H .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (11) :1426-1428
[6]   Unusual extracardiac findings detected on myocardial perfusion single photon emission computed tomography studies with Tc-99m sestamibi [J].
Gedik, Gonca Kara ;
Ergun, Eser Lay ;
Aslan, Mehmet ;
Caner, Biray .
CLINICAL NUCLEAR MEDICINE, 2007, 32 (12) :920-926
[7]  
Sabet A, 2012, 99MTC SESTAMIBI CLIN, P159
[8]   Detection of hepatic metastasis from medullary thyroid cancer with Tc-99m-MIBI scintigraphy in a patient with Sipple's syndrome [J].
Sato, S ;
Okumura, Y ;
Tamizu, A ;
Maki, K ;
Akaki, S ;
Takeda, Y ;
Kanazawa, S ;
Hiraki, Y .
ANNALS OF NUCLEAR MEDICINE, 2001, 15 (05) :443-446
[9]   Noncardiac findings on dual-isotope myocardial perfusion SPECT [J].
Williams, KA ;
Hill, KA ;
Sheridan, CM .
JOURNAL OF NUCLEAR CARDIOLOGY, 2003, 10 (04) :395-402