A study of the accuracy of CyberKnife spinal radiosurgery using skeletal structure tracking

被引:103
作者
Ho, Anthony K.
Fu, Dongshan
Cotrutz, Cristian
Hancock, Steven L.
Chang, Steven D.
Gibbs, Iris C.
Maurer, Calvin R., Jr.
Adler, John R., Jr.
机构
[1] Stanford Univ, Med Ctr, Dept Radiat Oncol, Stanford, CA 94305 USA
[2] Stanford Univ, Med Ctr, Dept Neurosurg, Stanford, CA 94305 USA
[3] Accuray Inc, Sunnyvale, CA USA
关键词
CyberKnife; image-guided robotic radiosurgery; spinal tumors; spine;
D O I
10.1227/01.NEU.0000249248.55923.EC
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: New technology has enabled the increasing use of radiosurgery to ablate spinal lesions. The first generation of the CyberKnife (Accuray, Inc., Sunnyvale, CA) image-guided radiosurgery system required implanted radiopaque markers (fiducials) to localize spinal targets. A recently developed and now commercially available spine tracking technology called Xsight (Accuray, Inc.) tracks skeletal structures and eliminates the need for implanted fiducials. The Xsight system localizes spinal targets by direct reference to the adjacent vertebral elements. This study sought to measure the accuracy of Xsight spine tracking and provide a qualitative assessment of overall system performance. METHODS: Total system error, which is defined as the distance between the centroids of the planned and delivered dose distributions and represents all possible treatment planning and delivery errors, was measured using a realistic, anthropomorphic head-and-neck phantom. The Xsight tracking system error component of total system error was also computed by retrospectively analyzing image data obtained from eleven patients with a total of 44 implanted fiducials who underwent CyberKnife spinal radiosurgery. RESULTS: The total system error of the Xsight targeting technology was measured to be 0.61 mm. The tracking system error component was found to be 0.49 mm. CONCLUSION: The Xsight spine tracking system is practically important because it is accurate and eliminates the use of implanted fiducials. Experience has shown this technology to be robust under a wide range of clinical circumstances.
引用
收藏
页码:147 / 156
页数:10
相关论文
共 38 条
  • [1] Image-guided robotic radiosurgery
    Adler, JR
    Murphy, MJ
    Chang, SD
    Hancock, SL
    [J]. NEUROSURGERY, 1999, 44 (06) : 1299 - 1306
  • [2] CyberKnife frameless radiosurgery for the treatment of extracranial benign tumors
    Bhatnagar, AK
    Gerszten, PC
    Ozhasaglu, C
    Vogel, WJ
    Kalnicki, S
    Welch, WC
    Burton, SA
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2005, 4 (05) : 571 - 576
  • [3] Staged stereotactic irradiation for acoustic neuroma
    Chang, SD
    Gibbs, IC
    Sakamoto, GT
    Lee, E
    Oyelese, A
    Adler, JR
    [J]. NEUROSURGERY, 2005, 56 (06) : 1254 - 1261
  • [4] An analysis of the accuracy of the Cyberknife: A robotic nameless stereotactic radiosurgical system
    Chang, SD
    Main, W
    Martin, DP
    Gibbs, IC
    Heilbrun, MP
    [J]. NEUROSURGERY, 2003, 52 (01) : 140 - 146
  • [5] Chang SD, 2005, AM J CANC, V4, P383, DOI DOI 10.2165/00024669-200504060-00005
  • [6] Robotic whole body stereotactic radiosurgery:: clinical advantages of the CyberKnife® integrated system
    Coste-Manière, É
    Olender, D
    Kilby, W
    Schulz, RA
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2005, 1 (02) : 28 - 39
  • [7] CyberKnife stereotactic radiosurgical treatment of spinal tumors for pain control and quality of life
    Degen, JW
    Gagnon, GJ
    Voyadzis, JM
    McRae, DA
    Lunsden, M
    Dieterich, S
    Molzahn, I
    Henderson, FC
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2005, 2 (05) : 540 - 549
  • [8] Cyberknife radiosurgery for benign intradural extramedullary spinal tumors
    Dodd, RL
    Ryu, MR
    Kamnerdsupaphon, P
    Gibbs, IC
    Chang, SD
    Adler, JR
    [J]. NEUROSURGERY, 2006, 58 (04) : 674 - 684
  • [9] Predicting error in rigid-body point-based registration
    Fitzpatrick, JM
    West, JB
    Maurer, CR
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) : 694 - 702
  • [10] Fu D, 2006, INT J COMPUT ASS RAD, V1, P198