Non-invasive stroke volume measurement and passive leg raising predict volume responsiveness in medical ICU patients: an observational cohort study

被引:99
作者
Thiel, Steven W. [1 ]
Kollef, Marin H. [1 ]
Isakow, Warren [1 ]
机构
[1] Washington Univ, Sch Med, Div Pulm & Crit Care, St Louis, MO 63110 USA
来源
CRITICAL CARE | 2009年 / 13卷 / 04期
关键词
CRITICALLY-ILL PATIENTS; PULMONARY-ARTERY CATHETERS; CARDIAC FILLING PRESSURES; INTENSIVE-CARE UNITS; ACUTE LUNG INJURY; FLUID RESPONSIVENESS; SEPTIC SHOCK; SURGICAL-PATIENTS; CONTROLLED-TRIAL; OUTPUT;
D O I
10.1186/cc7955
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction The assessment of volume responsiveness and the decision to administer a fluid bolus is a common dilemma facing physicians caring for critically ill patients. Static markers of cardiac preload are poor predictors of volume responsiveness, and dynamic markers are often limited by the presence of spontaneous respirations or cardiac arrhythmias. Passive leg raising (PLR) represents an endogenous volume challenge that can be used to predict fluid responsiveness. Methods Medical intensive care unit (ICU) patients requiring volume expansion were eligible for enrollment. Non-invasive measurements of stroke volume (SV) were obtained before and during PLR using a transthoracic Doppler ultrasound device prior to volume expansion. Measurements were then repeated following volume challenge to classify patients as either volume responders or non-responders based on their hemodynamic response to volume expansion. The change in SV from baseline during PLR was then compared with the change in SV with volume expansion to determine the ability of PLR in conjunction with SV measurement to predict volume responsiveness. Results A total of 102 fluid challenges in 89 patients were evaluated. In 47 of the 102 fluid challenges (46.1%), SV increased by >= 15% after volume infusion (responders). A SV increase induced by PLR of >= 15% predicted volume responsiveness with a sensitivity of 81%, specificity of 93%, positive predictive value of 91% and negative predictive value of 85%. Conclusions Non-invasive SV measurement and PLR can predict fluid responsiveness in a broad population of medical ICU patients. Less than 50% of ICU patients given fluid boluses were volume responsive.
引用
收藏
页数:9
相关论文
共 41 条
[1]   Negative fluid balance predicts survival in patients with septic shock - A retrospective pilot study [J].
Alsous, F ;
Khamiees, M ;
DeGirolamo, A ;
Amoateng-Adjepong, Y ;
Manthous, CA .
CHEST, 2000, 117 (06) :1749-1754
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   RETRACTED: Volume replacement strategies on intensive care units: results from a postal survey (Retracted Article) [J].
Boldt, J ;
Lenz, M ;
Kumle, B ;
Papsdorf, M .
INTENSIVE CARE MEDICINE, 1998, 24 (02) :147-151
[4]   Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients [J].
Boulain, T ;
Achard, JM ;
Teboul, JL ;
Richard, C ;
Perrotin, D ;
Ginies, G .
CHEST, 2002, 121 (04) :1245-1252
[5]   Effects of intravenous fluid restriction on postoperative complications: Comparison of two perioperative fluid regimens - A randomized assessor-blinded multicenter trial [J].
Brandstrup, B ;
Tonnesen, H ;
Beier-Holgersen, R ;
Hjortso, E ;
Ording, H ;
Lindorff-Larsen, K ;
Rasmussen, MS ;
Lanng, C ;
Wallin, L ;
Iversen, LH ;
Gramkow, CS ;
Okholm, M ;
Blemmer, T ;
Svendsen, PE ;
Rottensten, HH ;
Thage, B ;
Riis, J ;
Jeppesen, IS ;
Teilum, D ;
Christensen, AM ;
Graungaard, B ;
Pott, F .
ANNALS OF SURGERY, 2003, 238 (05) :641-648
[6]   Cardiac output estimation with a new Doppler device after off-pump coronary artery bypass surgery [J].
Chand, Rajesh ;
Mehta, Yatin ;
Trehan, Naresh .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2006, 20 (03) :315-319
[7]   The effectiveness of right heart catheterization in the initial care of critically ill patients [J].
Connors, AF ;
Speroff, T ;
Dawson, NV ;
Thomas, C ;
Harrell, FE ;
Wagner, D ;
Desbiens, N ;
Goldman, L ;
Wu, AW ;
Califf, RM ;
Fulkerson, WJ ;
Vidaillet, H ;
Broste, S ;
Bellamy, P ;
Lynn, J ;
Knaus, WA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11) :889-897
[8]  
Dey Ian, 2005, Emerg Med Australas, V17, P193
[9]   A METHOD OF COMPARING THE AREAS UNDER RECEIVER OPERATING CHARACTERISTIC CURVES DERIVED FROM THE SAME CASES [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1983, 148 (03) :839-843
[10]   Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial [J].
Harvey, S ;
Harrison, DA ;
Singer, M ;
Ashcroft, J ;
Jones, CM ;
Elbourne, D ;
Brampton, W ;
Williams, D ;
Young, D ;
Rowan, K .
LANCET, 2005, 366 (9484) :472-477