Optimizing the ventilated double window for solar collection

被引:25
作者
Carlos, Jorge S. [1 ]
机构
[1] Univ Beira Interior, Ctr Mat & Bldg Technol CMADE UBI, Edificio 2 Engn, P-6200001 Covilha, Portugal
关键词
Ventilated double window; Preheating air; Solar heat gain; Passive system; DECREMENT FACTOR; AIR WINDOW; TIME-LAG; BUILDINGS; SIMULATIONS; PERFORMANCE; SAVINGS; SYSTEM;
D O I
10.1016/j.solener.2017.04.063
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Windows have been under study for the last decade due to their improvements and for being the lowest thermal resistance component of the facades. Amongst this component, the building also loses heat as a result of airing needs. Thermal losses through windows and ventilation may represent a large percentage of the whole thermal losses of the building. The double ventilated window is one of several construction systems that preheat the incoming air. It also reduces thermal losses through windows, reducing the heating load of the building. Several studies have shown the performance of the ventilated double window under different climatic conditions as well as the influence of different inputs. This paper shows how this passive air heating system can be improved in order to collect more solar heat. Thermal balance was improved by 8.4% and 12.5% in Braganca and Evora, respectively, while the delivered air temperature increased from 9.8 degrees C to 11.9 degrees C and from 13.5 degrees C to 17.4 degrees C in Braganca end Evora, respectively. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:454 / 462
页数:9
相关论文
共 22 条
[1]   Test cell analysis of the use of a supply air window as a passive solar component [J].
Baker, PH ;
McEvoy, M .
SOLAR ENERGY, 2000, 69 (02) :113-130
[2]   Energy demands and potential savings in European office buildings: Case studies based on EnergyPlus simulations [J].
Boyano, A. ;
Hernandez, P. ;
Wolf, O. .
ENERGY AND BUILDINGS, 2013, 65 :19-28
[3]   Evolutive Housing System: Refurbishment with new technologies and unsteady simulations of energy performance [J].
Buratti, C. ;
Belloni, E. ;
Palladino, D. .
ENERGY AND BUILDINGS, 2014, 74 :173-181
[4]  
Carlos J. S., 2016, INDOOR BUILT ENV
[5]   Heat recovery versus solar collection in a ventilated double window [J].
Carlos, Jorge S. ;
Corvacho, Helena ;
Silva, Pedro D. ;
Castro-Gomes, J. P. .
APPLIED THERMAL ENGINEERING, 2012, 37 :258-266
[6]   RETROFIT MEASURES IN OLD ELEMENTARY SCHOOL BUILDINGS TOWARDS ENERGY EFFICIENCY [J].
Carlos, Jorge S. ;
Corvacho, Helena .
JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2010, 16 (04) :567-576
[7]   Modelling and simulation of a ventilated double window [J].
Carlos, Jorge S. ;
Corvacho, Helena ;
Silva, Pedro D. ;
Castro-Gomes, J. P. .
APPLIED THERMAL ENGINEERING, 2011, 31 (01) :93-102
[8]   Real climate experimental study of two double window systems with preheating of ventilation air [J].
Carlos, Jorge S. ;
Corvacho, Helena ;
Silva, Pedro D. ;
Castro-Gomes, J. P. .
ENERGY AND BUILDINGS, 2010, 42 (06) :928-934
[9]  
Carlos Jorge. S, 2013, J RENEWABLE ENERGY, V2013, P1
[10]  
Carlos Jorge S., 2013, INT J HOUS SCI APPL, V37, P175