Real-time label-free detection of complement activation products in human serum by white light reflectance spectroscopy

被引:16
|
作者
Petrou, Panagiota S. [2 ]
Ricklin, Daniel [1 ]
Zavali, Maria [3 ]
Raptis, Ioannis [3 ]
Kakabakos, Sotirios E. [2 ]
Misiakos, Konstantinos [3 ]
Lambris, John D. [1 ]
机构
[1] Univ Penn, Dept Pathol & Lab Med, Philadelphia, PA 19104 USA
[2] NCSR Demokritos, Inst Radioisotopes & Radiodiagnost Prod, Immunoassay Immunosensors Lab, GR-15310 Aghia Paraskevi, Greece
[3] NCSR Demokritos, Inst Microelect, GR-15310 Aghia Paraskevi, Greece
基金
美国国家卫生研究院;
关键词
Complement; C3b; White light reflectance spectroscopy; Surface plasmon resonance; Label-free detection; Biomarker analysis; MONOCLONAL-ANTIBODIES; ALTERNATIVE PATHWAY; INTERNAL THIOESTER; C3; COMPONENT; DISEASE; BINDING; C-3;
D O I
10.1016/j.bios.2009.04.040
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We present a label-free, real-time sensor based on white light reflectance spectroscopy for quantitating the complement activation product C3b and its metabolites as a biomarker in human serum. Our novel sensor allows real-time monitoring of biomolecular reactions (in this case, antigen-antibody reactions) taking place on a reflective surface within a flow cell. Detection was based on monitoring the increase in film thickness caused by its immunoreaction with a specific antibody; this reaction was seen as a shift in the wavelength at which constructive interference was observed. Quantitation of C3b was achieved by immobilizing a specific mouse monoclonal antibody onto the refractive surface and monitoring the rate of the signal changes occurring during the first 60 s of the immunoreaction between the antibody and known concentrations of purified C3b or dilutions of complement-activated human serum. The lowest detectable concentration of purified C3b was 20 ng/mL, and complement activation products in human serum samples could be detected at dilutions as high as 6000-fold. The advantages of the method include its relatively low cost, short analysis time, and high assay sensitivity and reliability. Thus, this novel assay method can be used to monitor serum C3b produced as a result of complement activation in a variety of normal and pathologic conditions. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:3359 / 3364
页数:6
相关论文
共 50 条
  • [21] Electrokinetic effect for molecular recognition: A label-free approach for real-time biosensing
    Dev, Apurba
    Horak, Josef
    Kaiser, Andreas
    Yuan, Xichen
    Perols, Anna
    Bjork, Per
    Karlstrom, Amelie Eriksson
    Kleimann, Pascal
    Linnros, Jan
    BIOSENSORS & BIOELECTRONICS, 2016, 82 : 55 - 63
  • [22] Label-free characterization and real-time monitoring of cell uptake of extracellular vesicles
    Koponen, Annika
    Kerkela, Erja
    Rojalin, Tatu
    Lazaro-Ibanez, Elisa
    Suutari, Teemu
    Saari, Heikki O.
    Siljander, Pia
    Yliperttula, Marjo
    Laitinen, Saara
    Viitala, Tapani
    BIOSENSORS & BIOELECTRONICS, 2020, 168
  • [23] Microneedle biosensor: A method for direct label-free real time protein detection
    Esfandyarpour, Rahim
    Esfandyarpour, Hesaam
    Javanmard, Mehdi
    Harris, James S.
    Davis, Ronald W.
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 177 : 848 - 855
  • [24] A silicon-based electrochemical sensor for highly sensitive, specific, label-free and real-time DNA detection
    Guo, Yuanyuan
    Su, Shao
    Wei, Xinpan
    Zhong, Yiling
    Su, Yuanyuan
    Huang, Qing
    Fan, Chunhai
    He, Yao
    NANOTECHNOLOGY, 2013, 24 (44)
  • [25] Impedance spectroscopy-An outstanding method for label-free and real-time discrimination between brain and tumor tissue in vivo
    Jahnke, Heinz-Georg
    Heimann, Axel
    Azendorf, Ronny
    Mpoukouvalas, Konstantinos
    Kempski, Oliver
    Robitzki, Andrea A.
    Charalampaki, Patra
    BIOSENSORS & BIOELECTRONICS, 2013, 46 : 8 - 14
  • [26] Real-time label-free assessment of T7 DNA polymerase immobilization
    Dronina, Julija
    Plausinaitis, Deivis
    Samukaite-Bubniene, Urte
    Ramanavicius, Arunas
    MATERIALS TODAY NANO, 2022, 19
  • [27] Real-Time and Label-Free Detection of Cellular Response to Signaling Mediated by Distinct Subclasses of Epidermal Growth Factor Receptors
    Chen, Jennifer Y.
    Li, Minghong
    Penn, Lynn S.
    Xi, Jun
    ANALYTICAL CHEMISTRY, 2011, 83 (08) : 3141 - 3146
  • [28] Real-time label-free detection and kinetic analysis of Etanercept-Protein A interactions using quartz crystal microbalance
    Dubiel, Evan A.
    Martin, Bruno
    Vigier, Sylvain
    Vermette, Patrick
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2017, 149 : 312 - 321
  • [29] Label-Free Real-Time Microarray Imaging of Cancer Protein-Protein Interactions and Their Inhibition by Small Molecules
    Walgama, Charuksha
    Al Mubarak, Zainab H.
    Zhang, Bing
    Akinwale, Mayowa
    Pathiranage, Anuruddha
    Deng, Junpeng
    Berlin, K. Darrell
    Benbrook, Doris M.
    Krishnan, Sadagopan
    ANALYTICAL CHEMISTRY, 2016, 88 (06) : 3130 - 3135
  • [30] Real-Time Label-Free Direct Electronic Monitoring of Topoisomerase Enzyme Binding Kinetics on Graphene
    Zuccaro, Laura
    Tesauro, Cinzia
    Kurkina, Tetiana
    Fiorani, Paola
    Yu, Hak Ki
    Knudsen, Birgitta R.
    Kern, Klaus
    Desideri, Alessandro
    Balasubramanian, Kannan
    ACS NANO, 2015, 9 (11) : 11166 - 11176