On the effect of using collision/reaction cell (CRC) technology in single-particle ICP-mass spectrometry (SP-ICP-MS)

被引:69
作者
Bolea-Fernandez, Eduardo [1 ]
Leite, Diego [2 ]
Rua-Ibarz, Ana [1 ,3 ]
Liu, Tong [1 ]
Woods, Glenn [4 ]
Aramendia, Maite [2 ,5 ]
Resano, Martin [2 ]
Vanhaecke, Frank [1 ]
机构
[1] Univ Ghent, Dept Chem Atom & Mass Spectrometry, A&MS Res Unit, Campus Sterre,Krijgslaan 281-512, B-9000 Ghent, Belgium
[2] Univ Zaragoza, Aragon Inst Engn Res I3A, Dept Analyt Chem, Pedro Cerbuna 12, E-50009 Zaragoza, Spain
[3] Flemish Inst Technol Res VITO, Boeretang 200, B-2400 Mol, Belgium
[4] Flemish Inst Technol Res VITO, 5500 Lakeside,Cheadle Royal Business Pk, Stockport SK8 3GR, Cheshire, England
[5] Ctr Univ Defensa Zaragoza, Carretera Huesca S-N, Zaragoza 50090, Spain
关键词
Nanoparticles; Single-particle ICP-MS/(MS); Collision/reaction cell; Spectral overlap; Chemical resolution; Peak width; INDUCTIVELY-COUPLED PLASMA; SIZE DISTRIBUTIONS; DATA-ACQUISITION; NANOPARTICLES; TIME; INTERFERENCES; NUMBER; TOOL; QUANTIFICATION; NANOMATERIALS;
D O I
10.1016/j.aca.2019.05.077
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, the effects of using collision/reaction cell (CRC) technology in quadrupole-based ICP-MS (ICP-QMS) instrumentation operated in single-particle (SP) mode have been assessed. The influence of (i) various CRC gases, (ii) gas flow rates, (iii) nanoparticle (NP) sizes and (iv) NP types was evaluated using Ag, Au and Pt NPs with both a traditional ICP-QMS instrument and a tandem ICP-mass spectrometer. It has been shown that using CRC technology brings about a significant increase in the NP signal peak width (from 0.5 up to 6 ms). This effect is more prominent for a heavier gas (e.g., NH3) than for a lighter one (e.g., H-2 or He). At a higher gas flow rate and/or for larger particle sizes > 100 nm), the NP signal duration was prolonged to a larger extent. This effect of using CRC technology has been further demonstrated by characterizing custom-made 50 and 200 nm Fe3O4 NPs (originally strongly affected by the occurrence of spectral overlap) using different CRC approaches (H-2 on-mass and NH3 mass-shift). The use of NH3 (monitoring of Fe as the Fe(NH3)(2)(+) reaction product ion at m/z = 90 amu) induces a significant peak broadening compared to that observed when using H-2 (6.10 +/- 1.60 vs. 0.94 +/- 0.49 ms). This extension of transit time can most likely be attributed to the collisions/interactions of the ion cloud generated by a single NP event with the CRC gas and it even precludes 50 nm Fe3O4 NPs to be detected when using the NH3 mass-shift approach. Based on these results, the influence of a longer peak width on the accuracy of SP-ICP-MS measurement data (NP size, particle number density and mass concentration) must be taken into account when using CRC technology as a means to overcome spectral overlap. To mitigate the potential detrimental effect of using CRC technology in the characterization of NPs via SP-ICP-MS(/MS), the use of light gases and low gas flow rates is recommended. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:95 / 106
页数:12
相关论文
共 54 条
[1]  
A. Technologies, 2019, AG 8900 TRIPL QUADR
[2]   Evaluation of number concentration quantification by single-particle inductively coupled plasma mass spectrometry: microsecond vs. millisecond dwell times [J].
Abad-Alvaro, Isabel ;
Pena-Vazquez, Elena ;
Bolea, Eduardo ;
Bermejo-Barrera, Pilar ;
Castillo, Juan R. ;
Laborda, Francisco .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (19) :5089-5097
[3]   Inductively coupled plasma - Tandem mass spectrometry (ICP-MS/MS): A powerful and universal tool for the interference-free determination of (ultra) trace elements - A tutorial review [J].
Balcaen, Lieve ;
Bolea-Fernandez, Eduardo ;
Resano, Martin ;
Vanhaecke, Frank .
ANALYTICA CHIMICA ACTA, 2015, 894 :7-19
[4]   Reaction chemistry and collisional processes in multipole devices for resolving isobaric interferences in ICP-MS [J].
Bandura, DR ;
Baranov, VI ;
Tanner, SD .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (05) :454-470
[5]   Characterization of SiO2 nanoparticles by single particle-inductively coupled plasma-tandem mass spectrometry (SP-ICP-MS/MS) [J].
Bolea-Fernandez, Eduardo ;
Leite, Diego ;
Rua-Ibarz, Ana ;
Balcaen, Lieve ;
Aramendia, Maite ;
Resano, Martin ;
Vanhaecke, Frank .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (11) :2140-2152
[6]   Overcoming spectral overlap via inductively coupled plasma-tandem mass spectrometry (ICPMS/MS). A tutorial review [J].
Bolea-Fernandez, Eduardo ;
Balcaen, Lieve ;
Resano, Martin ;
Vanhaecke, Frank .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (09) :1660-1679
[7]   A prototype of a new inductively coupled plasma time-of-flight mass spectrometer providing temporally resolved, multi-element detection of short signals generated by single particles and droplets [J].
Borovinskaya, Olga ;
Hattendorf, Bodo ;
Tanner, Martin ;
Gschwind, Sabrina ;
Guenther, Detlef .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (02) :226-233
[8]   Measuring nanoparticles size distribution in food and consumer products: a review [J].
Calzolai, L. ;
Gilliland, D. ;
Rossi, F. .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2012, 29 (08) :1183-1193
[9]   A signal deconvolution method to discriminate smaller nanoparticles in single particle ICP-MS [J].
Cornelis, Geert ;
Hassellov, Martin .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (01) :134-144
[10]   Colloid analysis by single particle inductively coupled plasma-mass spectroscopy: a feasibility study [J].
Degueldre, C ;
Favarger, PY .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2003, 217 (1-3) :137-142