Two-dimensional liquid chromatography normal-phase and reversed-phase separation of (co)oligomers

被引:72
作者
Jandera, Pavel [1 ]
Fischer, Jan [1 ]
Lahovska, Hana [1 ]
Novotna, Katerina [1 ]
Cesla, Petr [1 ]
Kolarova, Lenka [1 ]
机构
[1] Univ Pardubice, Dept Analyt Chem, Pardubice 53210, Czech Republic
关键词
column liquid chromatography; two-dimensional reversed-phase/normal-phase separations; comprehensive LC x LC; hydrophilic interaction liquid chromatography; ethylene oxide-propylene oxide (co)oligomers;
D O I
10.1016/j.chroma.2005.10.081
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Many samples contain compounds with various numbers of two or more regular structural groups. Such "multidimensional" samples (according to the Giddings' notation) are best separated in orthogonal chromatographic systems with different selectivities for the individual repeat structural groups, described by separation factors. Correlations between the repeat group selectivities characterize the degree of orthogonality and suitability of chromatographic systems for two-dimensional (2D) separations of two-dimensional samples. The range of the structural units in that can be resolved in a given time can be predicted on the basis of a model describing the repeat group selectivity in the first- and second-dimension systems. Two-dimensional liquid chromatographic system combining reversed-phase (RP) mode in the first dimension and normal-phase (NP) mode in the second dimension were studied with respect to the possibilities of in-line fraction transfer between the two modes. Hydrophilic interaction liquid chromatography (HILIC) with an armnopropyl silica column (APS) is more resistant than classical non-aqueous NP systems against adsorbent desactivation with aqueous solvents transferred in the fractions from the first, RP dimension to the second dimension. Hence, HILIC is useful as a second-dimension separation system for comprehensive RP-NP LC x LC. A comprehensive 2D RP-NP RPLC method was developed for comprehensive 2D separation of ethylene oxide-propylene oxide (EO-PO) (co)oligomers. The first-dimension RP system employed a 120 min gradient of acetonitrile in water on a C 18 microbore column at the flow-rate of 10 mu L/min. In the second dimension, isocratic HILIC NP with ethanol-dichloromethane-water mobile phase on an aminopropyl silica column at 0.5 mL/min was used. Ten microliter fractions were transferred from the RP to the HILIC NP system at I min switching valve cycle frequency. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:3 / 10
页数:8
相关论文
共 33 条
[1]   HYDROPHILIC-INTERACTION CHROMATOGRAPHY FOR THE SEPARATION OF PEPTIDES, NUCLEIC-ACIDS AND OTHER POLAR COMPOUNDS [J].
ALPERT, AJ .
JOURNAL OF CHROMATOGRAPHY, 1990, 499 :177-196
[2]  
Bertsch W, 1999, HRC-J HIGH RES CHROM, V22, P647, DOI 10.1002/(SICI)1521-4168(19991201)22:12<647::AID-JHRC647>3.0.CO
[3]  
2-V
[4]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :161-167
[5]   Comprehensive two-dimensional normal-phase (adsorption) - Reversed-phase liquid chromatography [J].
Dugo, P ;
Favoino, O ;
Luppino, R ;
Dugo, G ;
Mondello, L .
ANALYTICAL CHEMISTRY, 2004, 76 (09) :2525-2530
[6]   2-DIMENSIONAL COLUMN LIQUID-CHROMATOGRAPHIC TECHNIQUE FOR RESOLUTION OF COMPLEX-MIXTURES [J].
ERNI, F ;
FREI, RW .
JOURNAL OF CHROMATOGRAPHY, 1978, 149 (FEB) :561-569
[7]   SAMPLE DIMENSIONALITY - A PREDICTOR OF ORDER-DISORDER IN COMPONENT PEAK DISTRIBUTION IN MULTIDIMENSIONAL SEPARATION [J].
GIDDINGS, JC .
JOURNAL OF CHROMATOGRAPHY A, 1995, 703 (1-2) :3-15
[8]   Two dimensional reversed-phase-reversed-phase separations -: Isomeric separations incorporating C18 and carbon clad zirconia stationary phases [J].
Gray, M ;
Dennis, GR ;
Wormell, P ;
Shalliker, RA ;
Slonecker, P .
JOURNAL OF CHROMATOGRAPHY A, 2002, 975 (02) :285-297
[9]   Utilising retention correlation for the separation of oligostyrenes by coupled-column liquid chromatography [J].
Gray, MJ ;
Dennis, GR ;
Slonecker, PJ ;
Shalliker, RA .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1073 (1-2) :3-9
[10]   Comprehensive two-dimensional separations of complex mixtures using reversed-phase reversed-phase liquid chromatography [J].
Gray, MJ ;
Dennis, GR ;
Slonecker, PJ ;
Shalliker, RA .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1041 (1-2) :101-110