Features extraction of sensor array based PMFL technology for detection of rail cracks

被引:33
作者
Wang, Ping [1 ]
Xiong, Longhui [1 ]
Sun, Yinchun [1 ]
Wang, Haitao [1 ]
Tian, Guiyun [1 ,2 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Automat Engn, Nanjing 210016, Peoples R China
[2] Newcastle Univ, Sch Elect & Elect Engn, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
基金
美国国家科学基金会; 英国工程与自然科学研究理事会;
关键词
Pulsed magnetic flux leakage; Sensor array; Finite element; Time-domain analysis; Features extraction; PULSED EDDY-CURRENT;
D O I
10.1016/j.measurement.2013.09.047
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Pulsed magnetic flux leakage (PMFL) testing is a new emerging and effective electromagnetic non-destructive testing (NDT) technology which combines the conventional magnetic flux leakage (MFL) technology with the theory of pulsed current. Compared with single sensor, the sensor array can scan larger areas with higher speed and lower lapsus. Finite element method (FEM) is used to get the ideal signal of MFL with defects, including signal horizontal and vertical. According to the analysis of different signal of MFL with defects, the relation between magnetic signal and defect size is received. Then a full set of PMFL system based on sensor array is used to detect the standard specimens. In order to eliminate the noise and extract the feature, the detecting signal is analyzed and processed by some pre-treatments. In the process of time-domain analysis, every peak value of sensor signal is extracted as analyzing signal, then peak values are lined as output signal of the sensor array. By analyzing different characters of curve under different defect sizes, and getting corresponding characteristic quantities, the reasons of the errors are discussed. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:613 / 626
页数:14
相关论文
共 16 条
[1]  
Dai Guang, 2005, CHEM MACHINERY, V32, P279
[2]  
Dong C., 2011, AUT COMP ICAC 17 INT, P246
[3]   Reduction of Lift-Off Effects in Pulsed Eddy Current for Defect Classification [J].
He, Yunze ;
Pan, Mengchun ;
Luo, Feilu ;
Tian, Guiyun .
IEEE TRANSACTIONS ON MAGNETICS, 2011, 47 (12) :4753-4760
[4]   Defect classification based on rectangular pulsed eddy current sensor in different directions [J].
He, Yunze ;
Luo, Feilu ;
Pan, Mengchun ;
Hu, Xiangchao ;
Gao, Junzhe ;
Liu, Bo .
SENSORS AND ACTUATORS A-PHYSICAL, 2010, 157 (01) :26-31
[5]   Defect identification and evaluation based on three-dimensional magnetic field measurement of pulsed eddy current [J].
He, Yunze ;
Luo, Feilu ;
Hu, Xiangchao ;
Liu, Bo ;
Gao, Junzhe .
INSIGHT, 2009, 51 (06) :310-314
[6]  
Hu Jin-ping, 2006, SHANXI ELECT TECHNOL, V3, P52
[7]  
Liu Wen Hui, 2007, COMPUT ENG, V6, P236
[8]  
Ruan Xiao Fei, 2008, THESIS BEIJING JIAOT, V6
[9]  
Tang You Fu, 2004, RAILWAY COMPUT APPL, V5, P23
[10]   PEC thermography for imaging multiple cracks from rolling contact fatigue [J].
Wilson, John ;
Tian, Guiyun ;
Mukriz, Ilham ;
Almond, Darryl .
NDT & E INTERNATIONAL, 2011, 44 (06) :505-512