Precautions and strategies in using a commercial flatbed scanner for radiochromic film dosimetry

被引:162
作者
Paelinck, L. [1 ]
De Neve, W. [1 ]
DeWagter, C. [1 ]
机构
[1] Ghent Univ Hosp, Dept Radiotherapy, B-9000 Ghent, Belgium
关键词
D O I
10.1088/0031-9155/52/1/015
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study was to investigate the value of a commercially available flatbed scanner for film dosimetry with radiochromic film for external radiotherapy. The EPSON Pro 1680 Expression scanner was examined as a densitometer for two-dimensional film dosimetry with Gafchromic EBT film. An accurate and efficient scanning procedure was established. Possible drift and warm-up effects of the scanner were studied and the direct physical influence of the scanner light on the radiochromic film was assessed. Next, we investigated the scan field uniformity. Also, we examined if the accuracy of radiochromic film was improved by subtracting the optical density of the unirradiated blank film from the optical density of the irradiated film. To assess the accuracy of Gafchromic EBT film when the EPSON scanner was used as a densitometer, the depth dose of a 2 x 15 cm(2) field and the in-plane and cross-plane profiles of a 15 x 15 cm(2) field were measured and compared with diamond detector measurements. When taking consecutive scans, we found that the optical density taken from the first scan was about 1% higher than the optical density taken from subsequent scans. We attribute this to the warming up of the lamp of the scanner. Longer-term drift of the scanner was found to be absent. We found that the use of a correction matrix was necessary to correct for the non-uniform scanner response over the scan field. Subtracting the optical density of the unirradiated blank film from the irradiated film improves the precision of the Gafchromic EBT film. Depth dose and profile measurements with Gafchromic EBT film and the diamond detector are in agreement within 2.5%. The EPSON Pro 1680 Expression scanner is an excellent tool for accurate two-dimensional film dosimetry with Gafchromic EBT film provided that some precautions and corrections are taken into account.
引用
收藏
页码:231 / 242
页数:12
相关论文
共 50 条
  • [31] Computed tomography dose measurements with radiochromic films and a flatbed scanner
    Rampado, O.
    Garelli, E.
    Ropolo, R.
    MEDICAL PHYSICS, 2010, 37 (01) : 189 - 196
  • [32] GAFChromic film dosimetry with a flatbed color scanner for Leksell Gamma Knife therapy
    Yamauchi, M
    Tominaga, T
    Nakamura, O
    Ueda, R
    Hoshi, M
    MEDICAL PHYSICS, 2004, 31 (05) : 1243 - 1248
  • [33] Radiochromic EBT film dosimetry: Effect of film orientation and batch on the lateral correction of the scanner
    Paelinck, L.
    Ebongue, A. Ngwa
    De Neve, W.
    De Wagter, S.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S194 - S195
  • [34] Evaluation of a glassless photographic film scanner for high-gradient radiochromic film dosimetry
    De Puysseleyr, A.
    Srivastava, R. P.
    Paelinck, L.
    De Neve, W.
    De Wagter, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (01) : 127 - 142
  • [35] Calibration of GafChromic XR-RV3 radiochromic film for skin dose measurement using standardized x-ray spectra and a commercial flatbed scanner
    McCabe, Bradley P.
    Speidel, Michael A.
    Pike, Tina L.
    Van Lysel, Michael S.
    MEDICAL PHYSICS, 2011, 38 (04) : 1919 - 1930
  • [36] Radiochromic film dosimetry
    Soares, Christopher G.
    RADIATION MEASUREMENTS, 2006, 41 : S100 - S116
  • [37] Dosimetry using a radiochromic film and a mammography phantom
    Gotanda, Tatsuhiro
    Kawaji, Yasuyuki
    Yatake, Hidetoshi
    Imai, Shinya
    Akagawa, Takuya
    Katsuda, Toshizo
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (8-9) : 1007 - 1011
  • [38] Impact of Document Scanner Resolution on Raw Signal Noise in Radiochromic Film Dosimetry
    Devic, S.
    Tomic, N.
    Aldelaijan, S.
    Seuntjens, J.
    Moftah, B.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S695 - S696
  • [39] A protocol for accurate radiochromic film dosimetry using Radiochromic.com
    Mendez, Ignasi
    Jose Rovira-Escutia, Juan
    Casar, Bozidar
    RADIOLOGY AND ONCOLOGY, 2021, 55 (03) : 369 - 378
  • [40] A Simple Method for Quantifying and Reducing Lateral Response Artifact of Flatbed Scanner for Film Dosimetry
    Du, X.
    Rasmussen, B.
    MEDICAL PHYSICS, 2021, 48 (06)