Precautions and strategies in using a commercial flatbed scanner for radiochromic film dosimetry

被引:161
|
作者
Paelinck, L. [1 ]
De Neve, W. [1 ]
DeWagter, C. [1 ]
机构
[1] Ghent Univ Hosp, Dept Radiotherapy, B-9000 Ghent, Belgium
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2007年 / 52卷 / 01期
关键词
D O I
10.1088/0031-9155/52/1/015
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study was to investigate the value of a commercially available flatbed scanner for film dosimetry with radiochromic film for external radiotherapy. The EPSON Pro 1680 Expression scanner was examined as a densitometer for two-dimensional film dosimetry with Gafchromic EBT film. An accurate and efficient scanning procedure was established. Possible drift and warm-up effects of the scanner were studied and the direct physical influence of the scanner light on the radiochromic film was assessed. Next, we investigated the scan field uniformity. Also, we examined if the accuracy of radiochromic film was improved by subtracting the optical density of the unirradiated blank film from the optical density of the irradiated film. To assess the accuracy of Gafchromic EBT film when the EPSON scanner was used as a densitometer, the depth dose of a 2 x 15 cm(2) field and the in-plane and cross-plane profiles of a 15 x 15 cm(2) field were measured and compared with diamond detector measurements. When taking consecutive scans, we found that the optical density taken from the first scan was about 1% higher than the optical density taken from subsequent scans. We attribute this to the warming up of the lamp of the scanner. Longer-term drift of the scanner was found to be absent. We found that the use of a correction matrix was necessary to correct for the non-uniform scanner response over the scan field. Subtracting the optical density of the unirradiated blank film from the irradiated film improves the precision of the Gafchromic EBT film. Depth dose and profile measurements with Gafchromic EBT film and the diamond detector are in agreement within 2.5%. The EPSON Pro 1680 Expression scanner is an excellent tool for accurate two-dimensional film dosimetry with Gafchromic EBT film provided that some precautions and corrections are taken into account.
引用
收藏
页码:231 / 242
页数:12
相关论文
共 50 条
  • [1] What precautions should we use with a flatbed scanner for radiochromic film dosimetry
    Paelinck, L.
    De Wagter, C.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S518 - S519
  • [2] RADIOCHROMIC FILM DOSIMETRY USING A COMMERCIAL FLATBED DOCUMENT SCANNER: A FEASIBILITY STUDY
    Adamczyk, S.
    Litoborski, M.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S216 - S216
  • [3] Flatbed scanner stability for radiochromic film dosimetry
    Laosa, C.
    Calvo Ortega, J. F.
    Moragues Femenia, S.
    Casals, J.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S910 - S910
  • [4] Evaluation of a commercial flatbed document scanner and radiographic film scanner for radiochromic EBT film dosimetry
    Matney, Jason E.
    Parker, Brent C.
    Neck, Daniel W.
    Henkelmann, Greg
    Rosen, Isaac I.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (02): : 198 - 208
  • [5] Investigation of Commercial-Grade Flatbed Scanners and a Medical-Grade Scanner for Radiochromic EBT Film Dosimetry
    Syh, J.
    Patel, B.
    Syh, J.
    Wu, H.
    Rosen, L.
    Durci, M.
    Katz, S.
    Sibata, C.
    MEDICAL PHYSICS, 2012, 39 (06) : 3734 - 3734
  • [6] Temperature Effect During Radiation Exposure Period for Radiochromic Film Dosimetry Using Flatbed Scanner Densitometer
    Ren, T.
    Bourland, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E608 - E608
  • [7] Effect of mirror system and scanner bed of a flatbed scanner on lateral response artefact in radiochromic film dosimetry
    Shameem, Tarafder
    Bennie, Nick
    Butson, Martin
    Thwaites, David
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (04) : 1651 - 1663
  • [8] Strategies for accurate response assessment of radiochromic film using flatbed scanner for beam quality assurance
    Zhang, Xu-Dong
    Liu, Yuan-Hao
    Tang, Xiao-Bin
    Hsiao, Ming-Chen
    Chen, Wei-Lin
    Geng, Chang-Ran
    Shao, Wen-Cheng
    Gong, Chun-Hui
    Bortolussi, Silva
    Shu, Di-Yun
    NUCLEAR SCIENCE AND TECHNIQUES, 2019, 30 (11)
  • [9] Strategies for accurate response assessment of radiochromic film using flatbed scanner for beam quality assurance
    Xu-Dong Zhang
    Yuan-Hao Liu
    Xiao-Bin Tang
    Ming-Chen Hsiao
    Wei-Lin Chen
    Chang-Ran Geng
    Wen-Cheng Shao
    Chun-Hui Gong
    Silva Bortolussi
    Di-Yun Shu
    NuclearScienceandTechniques, 2019, 30 (11) : 3 - 11
  • [10] Strategies for accurate response assessment of radiochromic film using flatbed scanner for beam quality assurance
    Xu-Dong Zhang
    Yuan-Hao Liu
    Xiao-Bin Tang
    Ming-Chen Hsiao
    Wei-Lin Chen
    Chang-Ran Geng
    Wen-Cheng Shao
    Chun-Hui Gong
    Silva Bortolussi
    Di-Yun Shu
    Nuclear Science and Techniques, 2019, 30