Radiation Dose Management in Pediatric Brain CT According to Age and Weight as Continuous Variables

被引:14
作者
Inoue, Yusuke [1 ]
Itoh, Hiroyasu [2 ]
Waga, Anri [1 ]
Sasa, Ryosuke [2 ]
Mitsui, Kohei [1 ]
机构
[1] Kitasato Univ, Dept Diagnost Radiol, Sch Med, Sagamihara, Kanagawa 2520374, Japan
[2] Kitasato Univ Hosp, Dept Radiol, Sagamihara, Kanagawa 2520375, Japan
关键词
computed tomography; radiation dose; pediatrics; brain; diagnostic reference level; AUTOMATIC EXPOSURE CONTROL; DIAGNOSTIC REFERENCE LEVELS; TUBE CURRENT MODULATION; COMPUTED-TOMOGRAPHY; MULTIDETECTOR CT; LOCALIZER; DIRECTION; RISK;
D O I
10.3390/tomography8020079
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The diagnostic reference levels (DRLs) for pediatric brain computed tomography (CT) are provided for groups divided according to age. We investigated the relationships of radiation dose indices (volume CT dose index and dose length product) with age and weight, as continuous variables, in pediatric brain CT. In a retrospective analysis, 980 pediatric brain CT examinations were analyzed. Curve fitting was performed for plots of the CT dose indices versus age and weight, and equations to estimate age- and weight-dependent standard dose indices were derived. Standard dose indices were estimated using the equations, and the errors were calculated. The results showed a biphasic increase in dose indices with increasing age and weight, characterized by a rapid initial and subsequent slow increase. Logarithmic, power, and bilinear functions were well fitted to the plots, allowing estimation of standard dose indices at an arbitrary age or weight. Error analysis suggested that weight was mildly better than age and that the best results were obtained with the bilinear function. Curve fitting of the relationship between CT dose indices and age or weight facilitates the determination of standard dose indices in pediatric brain CT at each facility and is expected to aid the establishment and application of the DRLs.
引用
收藏
页码:985 / 998
页数:14
相关论文
共 50 条
  • [41] CT Radiation Dose Management: A Comprehensive Optimization Process for Improving Patient Safety
    Parakh, Anushri
    Kortesniemi, Mika
    Schindera, Sebastian T.
    RADIOLOGY, 2016, 280 (03) : 663 - 673
  • [42] Automated Pediatric Abdominal Effective Diameter Measurements Versus Age-Predicted Body Size for Normalization of CT Dose
    Cheng, Phillip M.
    Vachon, Linda A.
    Duddalwar, Vinay A.
    JOURNAL OF DIGITAL IMAGING, 2013, 26 (06) : 1151 - 1155
  • [43] Radiation dose levels of thoracic–lumbar spine CT in pediatric trauma patients and assessment of scan parameters for dose optimization
    Sevtap Arslan
    Mehmet Ruhi Onur
    Yasin Sarıkaya
    H. Nursun Özcan
    Mithat Haliloğlu
    Deniz Akata
    Pediatric Radiology, 2022, 52 : 65 - 74
  • [44] Low-tube-voltage selection for non-contrast-enhanced CT: Comparison of the radiation dose in pediatric and adult phantoms
    Shimonobo, Toshiaki
    Funama, Yoshinori
    Utsunomiya, Daisuke
    Nakaura, Takeshi
    Oda, Seitaro
    Kiguchi, Masao
    Masuda, Takanori
    Sakabe, Daisuke
    Yamashita, Yasuyuki
    Awai, Kazuo
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (01): : 197 - 201
  • [45] Simplifying Size-Specific Radiation Dose Estimates in Pediatric CT
    Khawaja, Ranish Deedar Ali
    Singh, Sarabjeet
    Vettiyil, Beth
    Lim, Ruth
    Gee, Michael
    Westra, Sjirk
    Kalra, Mannudeep K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (01) : 167 - 176
  • [46] Management of pediatric radiation dose using Fuji computed radiography
    D.W. MacCutcheon
    Pediatric Radiology, 2004, 34 : S201 - S206
  • [47] Management of pediatric radiation dose using Philips digital radiography
    U. Neitzel
    Pediatric Radiology, 2004, 34 : S227 - S233
  • [48] Management of pediatric radiation dose using Fuji computed radiography
    MacCutcheon, DW
    PEDIATRIC RADIOLOGY, 2004, 34 (Suppl 3) : S201 - S206
  • [49] Management of pediatric radiation dose using Philips digital radiography
    Neitzel, U
    PEDIATRIC RADIOLOGY, 2004, 34 (Suppl 3) : S227 - S233
  • [50] Radiation dose levels of thoracic-lumbar spine CT in pediatric trauma patients and assessment of scan parameters for dose optimization
    Arslan, Sevtap
    Onur, Mehmet Ruhi
    Sarikaya, Yasin
    Ozcan, H. Nursun
    Haliloglu, Mithat
    Akata, Deniz
    PEDIATRIC RADIOLOGY, 2022, 52 (01) : 65 - 74