Radiation Dose Management in Pediatric Brain CT According to Age and Weight as Continuous Variables

被引:14
|
作者
Inoue, Yusuke [1 ]
Itoh, Hiroyasu [2 ]
Waga, Anri [1 ]
Sasa, Ryosuke [2 ]
Mitsui, Kohei [1 ]
机构
[1] Kitasato Univ, Dept Diagnost Radiol, Sch Med, Sagamihara, Kanagawa 2520374, Japan
[2] Kitasato Univ Hosp, Dept Radiol, Sagamihara, Kanagawa 2520375, Japan
关键词
computed tomography; radiation dose; pediatrics; brain; diagnostic reference level; AUTOMATIC EXPOSURE CONTROL; DIAGNOSTIC REFERENCE LEVELS; TUBE CURRENT MODULATION; COMPUTED-TOMOGRAPHY; MULTIDETECTOR CT; LOCALIZER; DIRECTION; RISK;
D O I
10.3390/tomography8020079
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The diagnostic reference levels (DRLs) for pediatric brain computed tomography (CT) are provided for groups divided according to age. We investigated the relationships of radiation dose indices (volume CT dose index and dose length product) with age and weight, as continuous variables, in pediatric brain CT. In a retrospective analysis, 980 pediatric brain CT examinations were analyzed. Curve fitting was performed for plots of the CT dose indices versus age and weight, and equations to estimate age- and weight-dependent standard dose indices were derived. Standard dose indices were estimated using the equations, and the errors were calculated. The results showed a biphasic increase in dose indices with increasing age and weight, characterized by a rapid initial and subsequent slow increase. Logarithmic, power, and bilinear functions were well fitted to the plots, allowing estimation of standard dose indices at an arbitrary age or weight. Error analysis suggested that weight was mildly better than age and that the best results were obtained with the bilinear function. Curve fitting of the relationship between CT dose indices and age or weight facilitates the determination of standard dose indices in pediatric brain CT at each facility and is expected to aid the establishment and application of the DRLs.
引用
收藏
页码:985 / 998
页数:14
相关论文
共 50 条
  • [31] Assessment of pediatric radiation doses in brain CT procedures
    Bawazeer, O.
    Saleem, R.
    Alhazmi, M.
    Asiri, N.
    Mohammed, T.
    Alsaab, A.
    Algethami, M.
    Sedayo, A.
    Ajlouni, A.
    RADIOPROTECTION, 2022, 57 (04) : 305 - 310
  • [32] Radiation dose and image quality in pediatric chest CT: effects of iterative reconstruction in normal weight and overweight children
    Yoon, Haesung
    Kim, Myung-Joon
    Yoon, Choon-Sik
    Choi, Jiin
    Shin, Hyun Joo
    Kim, Hyun Gi
    Lee, Mi-Jung
    PEDIATRIC RADIOLOGY, 2015, 45 (03) : 337 - 344
  • [33] Achieving Routine Submillisievert CT Scanning: Report from the Summit on Management of Radiation Dose in CT
    McCollough, Cynthia H.
    Chen, Guang Hong
    Kalender, Willi
    Leng, Shuai
    Samei, Ehsan
    Taguchi, Katsuyuki
    Wang, Ge
    Yu, Lifeng
    Pettigrew, Roderic I.
    RADIOLOGY, 2012, 264 (02) : 567 - 580
  • [34] Low-Dose Volume-Perfusion CT of the Brain: Effects of Radiation Dose Reduction on Performance of Perfusion CT Algorithms
    Othman, A. E.
    Afat, S.
    Brockmann, C.
    Nikoubashman, O.
    Bier, G.
    Brockmann, M. A.
    Nikolaou, K.
    Tai, J. H.
    Yang, Z. P.
    Kim, J. H.
    Wiesmann, M.
    CLINICAL NEURORADIOLOGY, 2017, 27 (03) : 311 - 318
  • [35] Radiation Dose Reduction at Pediatric CT: Use of Low Tube Voltage and Iterative Reconstruction
    Nagayama, Yasunori
    Oda, Seitaro
    Nakaura, Takeshi
    Tsuji, Akinori
    Urata, Joji
    Furusawa, Mitsuhiro
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Kidoh, Masafumi
    Yamashita, Yasuyuki
    RADIOGRAPHICS, 2018, 38 (05) : 1421 - +
  • [36] Use of a Dedicated Pediatric CT Imaging Service Associated With Decreased Patient Radiation Dose
    Borders, Heather L.
    Barnes, Courtney L.
    Parks, David C.
    Jacobsen, Jerilynn R.
    Zhou, Yong
    Hasselquist, Bruce E.
    Betz, Bradford W.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2012, 9 (05) : 340 - 343
  • [37] Variation in CT Pediatric Head Examination Radiation Dose: Results From a National Survey
    Kanal, Kalpana M.
    Graves, Janessa M.
    Vavilala, Monica S.
    Applegate, Kimberly E.
    Jarvik, Jeffrey G.
    Rivara, Frederick P.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (03) : W293 - W301
  • [38] Factors that can be Attributable to Radiation Dose Reduction among Pediatric Age Group Undergoing Brain Computed Tomography (Practices at KHMC, Jordan)
    Nsoor, Nariman
    WORLD FAMILY MEDICINE, 2009, 7 (07): : 26 - 29
  • [39] Radiation dose management in thoracic CT: an international survey
    Molinari, Francesco
    Tack, Denis M.
    Boiselle, Philip
    Ngo, Long
    Mueller-Mang, Christina
    Litmanovich, Diana
    Bankier, Alexander A.
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2013, 19 (03) : 201 - U156
  • [40] Automated Pediatric Abdominal Effective Diameter Measurements Versus Age-Predicted Body Size for Normalization of CT Dose
    Phillip M. Cheng
    Linda A. Vachon
    Vinay A. Duddalwar
    Journal of Digital Imaging, 2013, 26 : 1151 - 1155