Radiation Dose Management in Pediatric Brain CT According to Age and Weight as Continuous Variables

被引:14
|
作者
Inoue, Yusuke [1 ]
Itoh, Hiroyasu [2 ]
Waga, Anri [1 ]
Sasa, Ryosuke [2 ]
Mitsui, Kohei [1 ]
机构
[1] Kitasato Univ, Dept Diagnost Radiol, Sch Med, Sagamihara, Kanagawa 2520374, Japan
[2] Kitasato Univ Hosp, Dept Radiol, Sagamihara, Kanagawa 2520375, Japan
关键词
computed tomography; radiation dose; pediatrics; brain; diagnostic reference level; AUTOMATIC EXPOSURE CONTROL; DIAGNOSTIC REFERENCE LEVELS; TUBE CURRENT MODULATION; COMPUTED-TOMOGRAPHY; MULTIDETECTOR CT; LOCALIZER; DIRECTION; RISK;
D O I
10.3390/tomography8020079
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The diagnostic reference levels (DRLs) for pediatric brain computed tomography (CT) are provided for groups divided according to age. We investigated the relationships of radiation dose indices (volume CT dose index and dose length product) with age and weight, as continuous variables, in pediatric brain CT. In a retrospective analysis, 980 pediatric brain CT examinations were analyzed. Curve fitting was performed for plots of the CT dose indices versus age and weight, and equations to estimate age- and weight-dependent standard dose indices were derived. Standard dose indices were estimated using the equations, and the errors were calculated. The results showed a biphasic increase in dose indices with increasing age and weight, characterized by a rapid initial and subsequent slow increase. Logarithmic, power, and bilinear functions were well fitted to the plots, allowing estimation of standard dose indices at an arbitrary age or weight. Error analysis suggested that weight was mildly better than age and that the best results were obtained with the bilinear function. Curve fitting of the relationship between CT dose indices and age or weight facilitates the determination of standard dose indices in pediatric brain CT at each facility and is expected to aid the establishment and application of the DRLs.
引用
收藏
页码:985 / 998
页数:14
相关论文
共 50 条
  • [21] Radiation Dose and Image Quality in Pediatric Neck CT
    Tipnis, S. V.
    Rieter, W. J.
    Patel, D.
    Stalcup, S. T.
    Matheus, M. G.
    Spampinato, M. V.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (06) : 1067 - 1073
  • [22] Radiation Dose for Routine Clinical Adult Brain CT: Variability on Different Scanners at One Institution
    Jaffe, Tracy A.
    Hoang, Jenny K.
    Yoshizumi, Terry T.
    Toncheva, Greta
    Lowry, Carolyn
    Ravin, Carl
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (02) : 433 - 438
  • [23] Radiation dose reduction in perfusion CT imaging of the brain: A review of the literature
    Othman, Ahmed E.
    Afat, Saif
    Brockmann, Marc A.
    Nikoubashman, Omid
    Brockmann, Carolin
    Nikolaou, Konstantin
    Wiesmann, Martin
    JOURNAL OF NEURORADIOLOGY, 2016, 43 (01) : 1 - 5
  • [24] Strategies for Reducing Radiation Dose in CT for Pediatric Patients: How We Do It
    Anh-Vu Ngo
    Winant, Abbey J.
    Lee, Edward Y.
    Phillips, Grace S.
    SEMINARS IN ROENTGENOLOGY, 2018, 53 (02) : 124 - 131
  • [25] Decreasing the effective radiation dose in pediatric craniofacial CT by changing head position
    Didier, Ryne A.
    Kuang, Anna A.
    Schwartz, Daniel L.
    Selden, Nathan R.
    Stevens, Donna M.
    Bardo, Dianna M. E.
    PEDIATRIC RADIOLOGY, 2010, 40 (12) : 1910 - 1917
  • [26] Asian consortium on radiation dose of pediatric cardiac CT (ASCI-REDCARD)
    Peter K. T. Hui
    Hyun Woo Goo
    Jing Du
    Janice J. K. Ip
    Suzu Kanzaki
    Young Jin Kim
    Supika Kritsaneepaiboon
    Oktavia Lilyasari
    Suvipaporn Siripornpitak
    Pediatric Radiology, 2017, 47 : 899 - 910
  • [27] Radiation dose associated with CT-guided drain placement for pediatric patients
    Schwartz, Cody J.
    Isaacson, Ari J.
    Fordham, Lynn Ansley
    Ivanovic, Marija
    Taylor, J. Bradford
    Dixon, Robert G.
    PEDIATRIC RADIOLOGY, 2017, 47 (06) : 718 - 723
  • [28] Asian consortium on radiation dose of pediatric cardiac CT (ASCI-REDCARD)
    Hui, Peter K. T.
    Goo, Hyun Woo
    Du, Jing
    Ip, Janice J. K.
    Kanzaki, Suzu
    Kim, Young Jin
    Kritsaneepaiboon, Supika
    Lilyasari, Oktavia
    Siripornpitak, Suvipaporn
    PEDIATRIC RADIOLOGY, 2017, 47 (08) : 899 - 910
  • [29] Does Real-Time Monitoring of Patient Dose With Dose Management Software Increase CT Technologists' Radiation Awareness?
    Heilmaier, Christina
    Zuber, Niklaus
    Bruijns, Bernardus
    Weishaupt, Dominik
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (05) : 1049 - 1055
  • [30] Radiation dose associated with CT-guided drain placement for pediatric patients
    Cody J. Schwartz
    Ari J. Isaacson
    Lynn Ansley Fordham
    Marija Ivanovic
    J. Bradford Taylor
    Robert G. Dixon
    Pediatric Radiology, 2017, 47 : 718 - 723