The MR-TOF-MS isobar separator for the TITAN facility at TRIUMF

被引:57
作者
Jesch, Christian [1 ]
Dickel, Timo [1 ,2 ]
Plass, Wolfgang R. [1 ,2 ]
Short, Devin [3 ]
Andres, Samuel Ayet San [1 ,2 ]
Dilling, Jens [4 ,5 ]
Geissel, Hans [1 ,2 ]
Greiner, Florian [1 ]
Lang, Johannes [1 ]
Leach, Kyle G. [3 ,4 ]
Lippert, Wayne [1 ]
Scheidenberger, Christoph [1 ,2 ]
Yavor, Mikhail I. [6 ]
机构
[1] Univ Giessen, D-35390 Giessen, Germany
[2] GSI Helmholtzzentrum Schwerionenforsch, D-64291 Darmstadt, Germany
[3] Simon Fraser Univ, Burnaby, BC V5A 1S6, Canada
[4] TRIUMF, Vancouver, BC, Canada
[5] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
[6] Russian Acad Sci, Inst Analyt Instrumentat, St Petersburg 198103, Russia
来源
HYPERFINE INTERACTIONS | 2015年 / 235卷 / 1-3期
关键词
Isobar separation; MR-TOF-MS; ISOL; Low-energy RIB; Mass measurements; Exotic nuclides; FLIGHT MASS-SPECTROMETRY; 2-PROTON RADIOACTIVITY; ION-SOURCE; BEAM; BETA; ISAC; EMISSION; ISOTOPES; NUCLEI;
D O I
10.1007/s10751-015-1184-2
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
At TRIUMF's Ion Trap for Atomic and Nuclear Science (TITAN) a multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) will extend TITAN's capabilities and facilitate mass measurements and in-trap decay spectroscopy of exotic nuclei that so far have not been possible due to strong isobaric contamination. This MR-TOF-MS will also enable mass measurements of very short-lived nuclides (half-life > 1 ms) that are produced in very low quantities (a few detected ions overall). In order to allow the installation of an MR-TOF-MS in the restricted space on the platform, on which the TITAN facility is located, novel mass spectrometric methods have been developed. Transport, cooling and distribution of the ions inside the device is done using a buffer gas-filled RFQ-based ion beam switchyard. Mass selection is achieved using a dynamic retrapping technique after time-of-flight analysis in an electrostatic isochronous reflector system. Only due to the combination of these novel methods the realization of an MR-TOF-MS based isobar separator at TITAN has become possible. The device has been built, commissioned off-line and is currently under installation at TITAN.
引用
收藏
页码:97 / 106
页数:10
相关论文
共 25 条
  • [1] AR-31 AND S-27 - BETA-DELAYED 2-PROTON EMISSION AND MASS EXCESS
    BORREL, V
    JACMART, JC
    POUGHEON, F
    ANNE, R
    DETRAZ, C
    GUILLEMAUDMUELLER, D
    MUELLER, AC
    BAZIN, D
    DELMORAL, R
    DUFOUR, JP
    HUBERT, F
    PRAVIKOFF, MS
    ROECKL, E
    [J]. NUCLEAR PHYSICS A, 1991, 531 (02) : 353 - 369
  • [2] Rare isotope beams at ISAC-target & ion source systems
    Bricault P.G.
    Ames F.
    Dombsky M.
    Kunz P.
    Lassen J.
    [J]. Hyperfine Interactions, 2014, 225 (1-3): : 25 - 49
  • [3] DISCOVERY OF BETA-DELAYED 2-PROTON RADIOACTIVITY - AL-22
    CABLE, MD
    HONKANEN, J
    PARRY, RF
    ZHOU, SH
    ZHOU, ZY
    CERNY, J
    [J]. PHYSICAL REVIEW LETTERS, 1983, 50 (06) : 404 - 406
  • [4] Chaudhuri A, 2011, TRIUMF EEC SUBMISS S, VS1333
  • [5] First spatial separation of a heavy ion isomeric beam with amultiple-reflection time-of-flight mass spectrometer
    Dickel, T.
    Plass, W. R.
    Andres, S. Ayet San
    Ebert, J.
    Geissel, H.
    Haettner, E.
    Hornung, C.
    Miskun, I.
    Pietri, S.
    Purushothaman, S.
    Reiter, M. P.
    Rink, A. -K.
    Scheidenberger, C.
    Weick, H.
    Dendooven, P.
    Diwisch, M.
    Greiner, F.
    Heisse, F.
    Knoebel, R.
    Lippert, W.
    Moore, I. D.
    Pohjalainen, I.
    Prochazka, A.
    Ranjan, M.
    Takechi, M.
    Winfield, J. S.
    Xu, X.
    [J]. PHYSICS LETTERS B, 2015, 744 : 137 - 141
  • [6] A high-performance multiple-reflection time-of-flight mass spectrometer and isobar separator for the research with exotic nuclei
    Dickel, T.
    Plass, W. R.
    Becker, A.
    Czok, U.
    Geissel, H.
    Haettner, E.
    Jesch, C.
    Kinsel, W.
    Petrick, M.
    Scheidenberger, C.
    Simon, A.
    Yavor, M. I.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 777 : 172 - 188
  • [7] Multiple-reflection time-of-flight mass spectrometry for in situ applications
    Dickel, T.
    Plass, W. R.
    Lang, J.
    Ebert, J.
    Geissel, H.
    Haettner, E.
    Jesch, C.
    Lippert, W.
    Petrick, M.
    Scheidenberger, C.
    Yavor, M. I.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 317 : 779 - 784
  • [8] Dickel T., UNPUB
  • [9] Mass measurements on highly charged radioactive ions, a new approach to high precision with TITAN
    Dilling, J
    Baartman, R
    Bricault, P
    Brodeur, M
    Blomeley, L
    Buchinger, F
    Crawford, J
    López-Urrutia, JRC
    Delheij, P
    Froese, M
    Gwinner, GP
    Ke, Z
    Lee, JKP
    Moore, RB
    Ryjkov, V
    Sikler, G
    Smith, M
    Ullrich, J
    Vaz, J
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2006, 251 (2-3) : 198 - 203
  • [10] The proposed TITAN facility at ISAC for very precise mass measurements on highly charged short-lived isotopes
    Dilling, J
    Bricault, P
    Smith, M
    Kluge, HJ
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2003, 204 : 492 - 496