High-resolution MR-imaging of the liver with T2-weighted sequences using integrated parallel imaging: Comparison of prospective motion correction and respiratory triggering

被引:76
作者
Zech, CJ
Herrmann, KA
Huber, A
Dietrich, O
Stemmer, A
Herzog, P
Reiser, MF
Schoenberg, SO
机构
[1] Munich Univ Clin, Inst Clin Radiol, D-81377 Munich, Germany
[2] Siemens Med Solut Erlangen, Erlangen, Germany
关键词
MRI; parallel imaging; liver; respiratory triggering; GRAPPA;
D O I
10.1002/jmri.20127
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare high-resolution T2-weigthed images of the liver with and without integrated parallel acquisition techniques (iPAT) using either breath-hold sequences in combination with prospective acquisition motion correction (PACE) or respiratory triggering. Materials and Methods: Ten volunteers and 10 patients underwent each four different high-resolution fast spin echo (FSE) T2-weigthed sequences with 5 mm slice thickness and a full 320 matrix: a multi-breath-hold FSE sequence with and without iPAT and PACE and a respiratory-triggered FSE sequence with and without iPAT. Image quality was rated with a five-point scale by two independent readers. Signal intensity measurements were performed on a water phantom. Results: The sequences with iPAT required a substantially shorter acquisition time without loss of image quality. Overall image quality was, rated equal for all sequences by both readers. Image time for nine slices with iPAT was 13 seconds (19 seconds without iPAT) with multi-breath-hold and on average 4:00 minutes (7:02 minutes without iPAT) with respiratory triggering. Imaging with the PACE technique resulted in more correct positioning of the image stacks. Conclusion: T2-weighted fast imaging with iPAT is feasible and results in high-quality images within a short acquisition time. Overall image quality is not negatively affected by iPAT.
引用
收藏
页码:443 / 450
页数:8
相关论文
共 21 条
[1]   Liver: T2-weighted MR imaging with breath-hold fast-recovery optimized fast spin-echo compared with breath-hold half-Fourier and non-breath-hold respiratory-triggered fast spin-echo pulse sequences [J].
Augui, J ;
Vignaux, O ;
Argaud, C ;
Coste, J ;
Gouya, H ;
Legmann, P .
RADIOLOGY, 2002, 223 (03) :853-859
[2]   THE EFFECT OF RESPIRATION ON THE CONTRAST AND SHARPNESS OF LIVER-LESIONS IN MRI [J].
BUTTS, K ;
RIEDERER, SJ ;
EHMAN, RL .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (01) :1-7
[3]   T2-WEIGHTED MR-IMAGING OF THE ABDOMEN - FAST SPIN-ECHO VS CONVENTIONAL SPIN-ECHO SEQUENCES [J].
CATASCA, JV ;
MIROWITZ, SA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) :61-67
[4]   Motion artifact in T2-weighted fast spin-echo images of the liver: Effect on image contrast and reduction of artifact using respiratory triggering in normal volunteers [J].
Choe, KA ;
Smith, RC ;
Wilkens, K ;
Constable, RT .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (02) :298-302
[5]   A SIGNAL-TO-NOISE CALIBRATION PROCEDURE FOR NMR IMAGING-SYSTEMS [J].
EDELSTEIN, WA ;
BOTTOMLEY, PA ;
PFEIFER, LM .
MEDICAL PHYSICS, 1984, 11 (02) :180-185
[6]   Liver masses: Replacement of conventional T2-weighted spin-echo MR imaging with breath-hold MR imaging [J].
Gaa, J ;
Hatabu, H ;
Jenkins, RL ;
Finn, JP ;
Edelman, RR .
RADIOLOGY, 1996, 200 (02) :459-464
[7]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[8]  
Griswold MA, 2000, MAGN RESON MED, V44, P602, DOI 10.1002/1522-2594(200010)44:4<602::AID-MRM14>3.0.CO
[9]  
2-5
[10]   Single breath-hold T2-weighted MR imaging of the liver: Value of single-shot fast spin-echo and multishot spin-echo echoplanar imaging [J].
Hori, M ;
Murakami, T ;
Kim, T ;
Kanematsu, M ;
Tsuda, K ;
Takahashi, S ;
Takamura, M ;
Hoshi, H ;
Nakamura, H .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (05) :1423-1431