Development and Experimental Investigations on Two Stage GM Type Pulse Tube Refrigerator for 20 K Applications

被引:1
作者
Gujarati, P. B. [1 ]
Desai, K. P. [1 ]
Naik, H. B. [1 ]
Atrey, M. D. [2 ]
机构
[1] SV Natl Inst Technol, Surat 395007, India
[2] Indian Inst Technol, Mumbai 400076, Maharashtra, India
来源
27TH INTERNATIONAL CRYOGENICS ENGINEERING CONFERENCE AND INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2018 (ICEC-ICMC 2018) | 2019年 / 502卷
关键词
D O I
10.1088/1757-899X/502/1/012026
中图分类号
O59 [应用物理学];
学科分类号
摘要
Because of the absence of any moving components at the cold region, low vibration and high reliability, two stage GM type pulse tube refrigerator (PTR) is nowadays preferred compared to conventional GM refrigerator for cooling of superconducting magnets, SQUIDS, and cryopumping applications. The second stage regenerative material plays an important role in achieving low temperature below 20 K. Leads balls with 0.2 mm to 0.4 mm average diameter was selected as second stage regenerator matrix material while 200 mesh of SS 304 material was filled in the first stage. A two stage GM type PTR was developed. A rotary valve was fabricated and the valve timing effects on cooling performance of PTR were also studied. The valve timings were varied by the different width of rotor slit forming the flow area with stator ports. The lowest no-load temperature of 18.52 K and cooling capacity of 7 W at 29.58 K were obtained with an optimum frequency of 1.6 Hz, charging pressure of 16.5 bar.
引用
收藏
页数:5
相关论文
共 10 条
  • [1] Atrey M D, 2002, P 18 CRYOG ENG C, P519
  • [2] Chokhawala M, 2000, ADV CRYOGENIC ENG A, P159
  • [3] Desai K P, 2002, P 18 CRYOG ENG C, P523
  • [4] Gifford W, 1964, J. Eng. Ind., V86, P264
  • [5] Transient analysis of single stage GM type double inlet pulse tube cryocooler
    Gujarati, P. B.
    Desai, K. P.
    Naik, H. B.
    Atrey, M. D.
    [J]. ADVANCES IN CRYOGENIC ENGINEERING, 2015, 101
  • [6] Karunanithi R, 2002, P 18 CRYOG ENG C, P539
  • [7] Experimental and theoretical studies of a two-stage pulse tube cryocooler operating down to 3 K
    Kasthurirengan, S.
    Srinivasa, G.
    Karthik, G. S.
    Nadig, D. S.
    Behera, U.
    Shafi, K. A.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (3-4) : 986 - 995
  • [8] Narayankhedkar K, 1973, ASME B, V95, P373
  • [9] Tarasov A.A., 1984, ADV CRYOGEN ENG, V29, P629, DOI [10.1007/978-1-4613-9865-372, DOI 10.1007/978-1-4613-9865-372]
  • [10] ZHU SW, 1990, CRYOGENICS, V30, P514, DOI 10.1016/0011-2275(90)90051-D