Milled Bar with PEEK and Metal Housings for Inclined Implants Supporting Mandibular Overdentures: 1-Year Clinical, Prosthetic, and Patient-Based Outcomes

被引:13
作者
Abdraboh, Abdelrahman Elsaid [1 ]
Elsyad, Moustafa Abdou [2 ]
Mourad, Samah Ibrahim [3 ]
Alameldeen, Hesham Ebrahim [4 ]
机构
[1] Beni Suef Univ, Fac Dent, Dept Removable Prosthodont, Bani Suwayf, Egypt
[2] Univ Mansoura, Dept Prosthodont, Fac Dent, Eldakahlia, Egypt
[3] Univ Mansoura, Dept Oral Surg, Fac Dent, Eldakahlia, Egypt
[4] Future Univ, Fac Oral & Dent Med, Dept Removable Prosthodont, Cairo, Egypt
关键词
computer-guided surgery; flapless procedure; inclined implants; overdenture; prostheses; randomized controlled clinical trial; MAXILLARY OVERDENTURES; IMMEDIATE-FUNCTION; ETHER-KETONE; SATISFACTION; RETENTION; CROWNS; REHABILITATION;
D O I
10.11607/jomi.8399
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This investigation aimed to evaluate clinical, prosthetic, and patient-based outcomes of a milled bar with polyether ether ketone (PEEK) and metal housings for inclined implants supporting mandibular overdentures. Materials and Methods: Eighteen edentulous participants received four implants in the interforaminal area of the mandible (two vertically and two distally inclined), and implants were connected with milled bars. Overdentures were attached to the bars with PEEK female housing (test group). The control group consisted of participants who received milled bar overdentures with conventional metal housings but were case matched to the test group and served as a historical cohort. Clinical parameters (Plaque Index, Gingival Index, pocket depth, and bone loss) were measured at baseline, 6 months, and 12 months. Patient satisfaction (using visual analog scale) and prosthetic complications were recorded after 12 months. Results: The control group showed a significantly higher plaque score and marginal bone resorption compared with the test group. The test group showed higher satisfaction with retention, stability, speech, and esthetics compared with the control group (P < .048). The test group showed a significantly lower incidence of female housing wear (P = .017), plastic clip wear (P < .001), and plastic clip fracture/renewal (P = .049) than the control group. No difference between groups was noted for other clinical, prosthetic, and patient-based outcomes. Conclusion: PEEK housing of a milled bar may be a successful alternative to conventional metal housing for inclined implants supporting mandibular overdentures, as it is associated with favorable clinical, prosthetic, and patient-based outcomes after 1 year.
引用
收藏
页码:982 / 989
页数:8
相关论文
共 39 条
[31]  
Mombelli A, 1987, Oral Microbiol Immunol, V2, P145, DOI 10.1111/j.1399-302X.1987.tb00298.x
[32]   In Vitro Shock Absorption Tests on Implant-Supported Crowns: Influence of Crown Materials and Luting Agents [J].
Rosentritt, Martin ;
Schneider-Feyrer, Sibylle ;
Behr, Michael ;
Preis, Verena .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (01) :116-122
[33]   Digital Production of a Zirconia, Implant-Supported Removable Prosthesis with an Individual Bar Attachment Milled from Polyether Ether Ketone: A Case History Report [J].
Spies, Benedikt C. ;
Petsch, Matthias ;
Kohal, Ralf-Joachim ;
Beuer, Florian .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (05) :471-474
[34]   Retention force of differently fabricated telescopic PEEK crowns with different tapers [J].
Stock, Veronika ;
Wagner, Christina ;
Merk, Susanne ;
Roos, Malgorzata ;
Schmidlin, Patrick R. ;
Eichberger, Marlis ;
Stawarczyk, Bogna .
DENTAL MATERIALS JOURNAL, 2016, 35 (04) :594-600
[35]   The Application of Rapid Prototyping in Prosthodontics [J].
Sun, Jian ;
Zhang, Fu-Qiang .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2012, 21 (08) :641-644
[36]   In vitro wear resistance, hardness and elastic modulus of artificial denture teeth [J].
Suwannaroop, Pii ;
Chaijareenont, Pisaisit ;
Koottathape, Natthavoot ;
Takahashi, Hidekazu ;
Arksornnukit, Mansuang .
DENTAL MATERIALS JOURNAL, 2011, 30 (04) :461-468
[37]  
Tipton Paul A, 2002, J Esthet Restor Dent, V14, P208, DOI 10.1111/j.1708-8240.2002.tb00166.x
[38]   The all-on-4 modified polyetheretherketone treatment approach: A clinical report [J].
Zoidis, Panagiotis .
JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (04) :516-521
[39]   The Use of a Modified Poly-Ether-Ether-Ketone (PEEK) as an Alternative Framework Material for Removable Dental Prostheses. A Clinical Report [J].
Zoidis, Panagiotis ;
Papathanasiou, Ioannis ;
Polyzois, Gregory .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (07) :580-584