Overestimation of 25-hydroxyvitamin D3 by increased ionisation efficiency of 3-epi-25-hydroxyvitamin D3 in LC-MS/MS methods not separating both metabolites as determined by an LC-MS/MS method for separate quantification of 25-hydroxyvitamin D3, 3-epi-25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum
被引:68
作者:
van den Ouweland, Johannes M. W.
[1
]
Beijers, Antonius M.
[1
]
van Daal, Henny
[1
]
机构:
[1] Canisius Wilhelmina Hosp, Dept Clin Chem, NL-6532 SZ Nijmegen, Netherlands
来源:
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
|
2014年
/
967卷
关键词:
C-3-epimer;
3-epi-25-hydroxyvitamin D-3;
25-hydroxyvitamin D;
LC-MS/MS;
MS response factor;
Ionisation behaviour;
TANDEM MASS-SPECTROMETRY;
C-3;
EPIMER;
D-3;
INFANTS;
ADULTS;
ACCOUNT;
D O I:
10.1016/j.jchromb.2014.07.021
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
Background: An LC-MS/MS method was developed for simultaneous quantification of 25-hydroxyvitamin D-3 (25(OH)D-3), 3-epi-25(OH)D-3, and 25(OH)D-2 in human serum. Methods: Sample preparation consisted of protein precipitation followed by off-line SPE. Calibration curves for each vitamin D metabolite were constructed in phosphate-buffered saline with 60 g/L albumin including its corresponding stable isotope labelled (SIL) internal standard. A pentafluorophenyl (PFP) analytical column was used to resolve 25(OH)D-3 from 25(OH)D-2 and 3-epi-25(OH)D-3, followed by SRM registration using positive ESI-MS/MS. Accuracy was assessed from measurement of samples with NIST reference method procedure (RMP) assigned values. The PFP LC-MS/MS method was compared to an in-house C-18 column LC-MS/MS method, not resolving 25(OH)D-3 from 3-epi-25(OH)D-3, using adult and newborn samples. Results: Intra-assay and inter-assay coefficients of variation were less than 4% and 7.5%, respectively for all three vitamin D metabolites; lower limits of quantification were 1, 1 and 2 nmol/L and linearity of methods were 1-500, 1-200 and 2-500 nmol/L for 25(OH)D-3, 3-epi-25(OH)D-3 and 25(OH)D-2, respectively. The PFP LC-MS/MS method showed minimal bias to the NIST RMP. Method comparison revealed that in the C-18 LC-MS/MS method, the 3-epi-25(OH)D-3 concentration is overestimated inadvertently not only from co-elution of both analytes, but also by an additional 30-40% higher ionisation efficiency of 3-epi-25(OH)D-3 when compared to 25(OH)D-3. Conclusion: This accurate LC-MS/MS method allows the simultaneous measurement of 25(OH)D-3, 3-epi-25(OH)D-3, and 25(OH)D-2 in human serum. Due to increased ionisation efficiency, the contribution of the 3-epi-25(OH)D-3 metabolite to the total 25(OH)D-3 concentration is significantly overestimated in MS methods that do not resolve 3-epi-25(OH)D-3 from 25(OH)D-3 and may compromise its use in infant samples known to have significant amounts of 3-epi-25(OH)D-3. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:195 / 202
页数:8