In-plane assessment of existing timber diaphragms in URM buildings via quasi-static and dynamic in-situ tests

被引:19
作者
Giongo, Ivan [1 ]
Dizhur, Dmytro [2 ]
Tomasi, Roberto [1 ]
Ingham, Jason M. [2 ]
机构
[1] Univ Trento, Dept Civil Environm & Mech Engn, Trento, Italy
[2] Univ Auckland, Dept Civil & Environm Engn, Auckland, New Zealand
来源
STRUCTURAL HEALTH ASSESSMENT OF TIMBER STRUCTURES | 2013年 / 778卷
关键词
Century old timber diaphragms; field testing; in-plane stiffness; wood diaphragm; natural period;
D O I
10.4028/www.scientific.net/AMR.778.495
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Mechanical and dynamic in-plane properties of timber diaphragms are known to be key parameters when determining both the local and global seismic response of unreinforced masonry (URM) buildings. However, few data pertaining to experimental campaigns on performance of existing timber diaphragms are available in the literature. In the work presented here, the outcomes of a field testing campaign conducted on full-scale 100 year old timber diaphragms are presented. Two specimens, being 5.6 x 9.6 m(2) and 4.7 x 9.6 m(2), were obtained from a 17.0 x 9.6 m(2) existing floor and were subjected to a series of cyclic and snap back tests in the direction orthogonal to the timber joists. Adhesive anchors were installed prior to testing due to the deficiencies of the original anchoring system to transfer shear forces. In order to reproduce the inertial load distribution, an ad hoc loading system was developed by means of wire ropes and steel pulleys. Following testing of the diaphragms in the as-built condition, the effect of different refurbishment techniques was investigated. From the results, it seems that even "simple" and costeffective solutions such as re-nailing of the flooring and the addition of thin plywood overlays are sufficient to achieve a significant increase in the equivalent shear stiffness.
引用
收藏
页码:495 / 502
页数:8
相关论文
共 11 条
[1]  
*AGB ASS, 1982, ABKTR05
[2]  
[Anonymous], P 9 PAC C EARTHQ ENG
[3]  
[Anonymous], 2007, ASCE/SEI 41-06
[4]  
[Anonymous], 2008, 14 WORLD C EARTHQ EN
[5]  
AS/NZS (Australian/New Zealand Standard), 2008, 22692008 ASNZS
[6]   Experimental Evaluation of the In-Plane Stiffness of Timber Diaphragms [J].
Brignola, Anna ;
Pampanin, Stefano ;
Podesta, Stefano .
EARTHQUAKE SPECTRA, 2012, 28 (04) :1687-1709
[7]  
Derakhshan H., 2011, THESIS
[8]  
FEMA, 2000, Prestandard and commentary for the seismic rehabilitation of buildings [electronic resource]/prepared by the American Society of Civil Engineers
[9]  
prepared for Federal Emergency Management Agency (FEMA 356)
[10]  
NZSEE, 2011, ASS IMPR UNR MAS BUI