Radiation dose of cardiac CT-what is the evidence?

被引:38
|
作者
Alkadhi, Hatem [1 ]
机构
[1] Inst Diagnost Radiol, CH-8071 Zurich, Switzerland
关键词
Cardiac; Computed tomography; Radiation dose; Risk; DUAL-SOURCE CT; SOURCE COMPUTED-TOMOGRAPHY; NONINVASIVE CORONARY-ANGIOGRAPHY; LEFT-VENTRICULAR FUNCTION; ACUTE CHEST-PAIN; IMAGE QUALITY; RECONSTRUCTION INTERVALS; DIAGNOSTIC-ACCURACY; MAGNETIC-RESONANCE; INITIAL-EXPERIENCE;
D O I
10.1007/s00330-009-1312-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Current evidence and most pertinent literature on the radiation dose of cardiac computed tomography (CT) for the noninvasive assessment of coronary artery disease are reviewed. The various means for adjusting CT protocols to lower the radiation to a level that is as low as reasonably achievable are discussed. It is shown that for the target population of cardiac CT, the direct visualization of the heart and coronary arteries outweighs the hypothetical risk of the investigation, provided that indications are prudent and the protocols appropriate.
引用
收藏
页码:1311 / 1315
页数:5
相关论文
共 50 条
  • [1] Radiation dose of cardiac CT—what is the evidence?
    Hatem Alkadhi
    European Radiology, 2009, 19 : 1311 - 1315
  • [2] Radiation Dose in Cardiac CT
    Mayo, John R.
    Leipsic, Jonathon A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (03) : 646 - 653
  • [3] Multislice CT angiography in cardiac imaging. Part III: radiation risk and dose reduction
    Sun, Z.
    Ng, K. H.
    SINGAPORE MEDICAL JOURNAL, 2010, 51 (05) : 374 - 380
  • [4] Strategies to reduce radiation dose in cardiac PET/CT
    Wu, Tung Hsin
    Wu, Nien-Yun
    Wang, Shyh-Jen
    Wu, Jay
    Mok, Greta S. P.
    Yang, Ching-Ching
    Huang, Tzung-Chi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S158 - S162
  • [5] Asian consortium on radiation dose of pediatric cardiac CT (ASCI-REDCARD)
    Hui, Peter K. T.
    Goo, Hyun Woo
    Du, Jing
    Ip, Janice J. K.
    Kanzaki, Suzu
    Kim, Young Jin
    Kritsaneepaiboon, Supika
    Lilyasari, Oktavia
    Siripornpitak, Suvipaporn
    PEDIATRIC RADIOLOGY, 2017, 47 (08) : 899 - 910
  • [6] Low Radiation Dose with Triple-Rule-Out CT Angiography in Diagnosis of Acute Chest Pain
    Liu, Jianhua
    Huang, Sa
    Zhang, Jichang
    Yuan, Qinghai
    CURRENT MEDICAL IMAGING REVIEWS, 2013, 9 (01) : 47 - 50
  • [7] Assessment of radiation safety in cardiac CT angiography
    Lee, Yuan-Hao
    Chang, Po-Yen
    Tay, Shee Yen
    Tsai, Cheng-Yu
    Cheng, Po-Hsin
    Lao, Wilson T.
    Chan, Wing P.
    MEDICINE, 2017, 96 (51)
  • [8] Dose optimization in cardiac CT
    Hedgire, Sandeep
    Ghoshhajra, Brian
    Kalra, Mannudeep
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 41 : 97 - 103
  • [9] Radiation dose in cardiac CT angiography: protocols and image quality
    Oliveira, L. C. G.
    Gottlieb, I.
    Rizzi, P.
    Lopes, R. T.
    Kodlulovich, S.
    RADIATION PROTECTION DOSIMETRY, 2013, 155 (01) : 73 - 80
  • [10] SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT
    Halliburton, Sandra S.
    Abbara, Suhny
    Chen, Marcus Y.
    Gentry, Ralph
    Mahesh, Mahadevappa
    Raff, Gilbert L.
    Shaw, Leslee J.
    Hausleiter, Joerg
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2011, 5 (04) : 198 - 224